HIGH-RESOLUTION FOURIER-TRANSFORM SPECTROSCOPY OF THE MEINEL SYSTEM OF OH

被引:95
|
作者
ABRAMS, MC
DAVIS, SP
RAO, MLP
ENGLEMAN, R
BRAULT, JW
机构
[1] UNIV CALIF BERKELEY,DEPT PHYS,BERKELEY,CA 94720
[2] UNIV NEW MEXICO,DEPT CHEM,ALBUQUERQUE,NM 87131
[3] NATL SOLAR OBSERV,TUCSON,AZ 85726
[4] ANDHRA UNIV,WALTAIR 530003,ANDHRA PRADESH,INDIA
来源
关键词
LABORATORY SPECTRA; MOLECULAR PROCESSES;
D O I
10.1086/192058
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The infrared spectrum of the hydroxyl radical OH, between 1850 and 9000 cm-1, has been measured with a Fourier transform spectrometer. The source, a hydrogen-ozone diffusion flame, was designed to study the excitation of rotation-vibration levels of the OH Meinel bands under conditions similar to those in the upper atmosphere which produce the nighttime OH airglow emission. Twenty-three bands were observed: nine bands in the DELTAupsilon = 1 sequence, nine bands in the DELTAupsilon = 2 sequence, and five bands in the DELTAupsilon = 3 sequence. A global nonlinear least-squares fit of 1696 lines yielded molecular parameters with a standard deviation of 0.003 cm-1. Term values are computed, and transition frequencies in the DELTAupsilon = 3, 4, 5, 6 sequences in the near-infrared are predicted.
引用
收藏
页码:351 / 395
页数:45
相关论文
共 50 条
  • [21] HIGH-RESOLUTION FOURIER-TRANSFORM INFRARED-SPECTROSCOPY OF THE FUNDAMENTAL BANDS OF HNC
    BURKHOLDER, JB
    SINHA, A
    HAMMER, PD
    HOWARD, CJ
    JOURNAL OF MOLECULAR SPECTROSCOPY, 1987, 126 (01) : 72 - 77
  • [22] NEW MODULAR INTERFEROMETER FOR FOURIER-TRANSFORM SPECTROSCOPY AT HIGH-RESOLUTION IN FAR IR
    BACHET, G
    COULON, R
    INFRARED PHYSICS, 1977, 17 (05): : 359 - 364
  • [23] High-resolution Fourier-transform spectroscopy of solid parahydrogen in the first overtone region
    Mengel, M
    Winnewisser, BP
    Winnewisser, M
    PHYSICAL REVIEW B, 1997, 55 (16): : 10420 - 10433
  • [24] HIGH-RESOLUTION SPECTROSCOPY OF SOME GASEOUS MOLECULES WITH A SUBMILLIMETER FOURIER-TRANSFORM SPECTROMETER
    SAKAI, K
    ICHIMURA, K
    MASUMOTO, H
    KITAGAWA, Y
    INFRARED PHYSICS, 1978, 18 (5-6): : 577 - 583
  • [25] HIGH-RESOLUTION FOURIER-TRANSFORM SPECTROSCOPY WITH PULSED LASER-INDUCED FLUORESCENCES
    STRINGAT, R
    FABRE, G
    CIRIO, L
    ROSS, A
    OPTICS COMMUNICATIONS, 1991, 81 (3-4) : 179 - 185
  • [26] HIGH-RESOLUTION FOURIER-TRANSFORM SPECTROSCOPY WITH PHASE CORRECTION IN REAL-TIME
    BOUCHER, CR
    NAYLOR, DA
    INFRARED PHYSICS, 1981, 21 (05): : 261 - 270
  • [27] High-resolution lensless Fourier-transform digital holography
    Bányász, I
    Kornis, J
    OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION IV, PTS 1 AND 2, 2005, 5856 : 71 - 79
  • [28] High-resolution Fourier-transform emission spectroscopy of the A1Π-X1Σ+system of AIH
    Department of Chemistry, University of Arizona, Tucson, AZ 85721, United States
    不详
    Applied Optics, 1996, 35 (16): : 2879 - 2883
  • [29] Analysis of distortions in high-resolution fourier-transform spectra
    Otto, W
    Lichtenthaler, J
    Tittel, HO
    MIKROCHIMICA ACTA, 1997, : 547 - 549
  • [30] EVALUATION OF FOURIER-TRANSFORM FILTER FOR HIGH-RESOLUTION ECG
    CHRISTENSON, DW
    REDDY, BRS
    ROWLANDSON, GI
    JOURNAL OF ELECTROCARDIOLOGY, 1989, 22 : 33 - 40