PRESTORAGE LEUKOCYTE REDUCTION OF CELLULAR BLOOD COMPONENTS

被引:11
作者
DZIK, S
机构
[1] Blood Bank and Tissue Typing Laboratory, Department of Pathology, Deaconess Hospital, Boston, MA
来源
TRANSFUSION SCIENCE | 1994年 / 15卷 / 02期
关键词
D O I
10.1016/0955-3886(94)90087-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
With the increasing demand for leukoreduced cellular blood components, many blood centers in Europe, North America, and Asia have begun to prepare leukocyte depleted cellular blood components prior to storage. Increased understanding of transfusion complications resulting from recipient exposure to residual donor leukocytes has focused attention on donor leukocytes during blood storage. This review examines production options for prestorage leukocyte removal, considers approaches to quality control, discusses proposed laboratory and clinical advantages of leukoreduction prior to storage compared with after storage, and suggests a strategy for cost-effective implementation of widespread prestorage leukocyte removal.
引用
收藏
页码:131 / 139
页数:9
相关论文
共 49 条
[1]  
Uda, Ohkuma, Ishii, Nishizaki, Preparation of blood components with a saline-adenine-glucose-maltose quadruple-pack system, Transfusion, 25, pp. 325-339, (1985)
[2]  
Hogman, Erikson, Hedlund, Wallvik, The bottom and top system: a new technique for blood component preparation and storage, Vox Sang, 55, pp. 211-217, (1988)
[3]  
Pietersz, Dekker, Reesink, Comparison of a conventional quadruple-bag system with a ‘top-and-bottom’ system for blood processing, Vox Sang, 59, pp. 205-208, (1990)
[4]  
Nakajo, Chiba, Takahashi, Sekiguchi, Comparison of a ‘top and bottom’ system with a conventional quadruple-bag system for blood-component preparation and storage, Clinical Application of Leukocyte Depletion, pp. 18-30, (1993)
[5]  
Fijnheer, Pietersz, deKorte, Et al., Platelet activation during preparation of platelet concentrates: a comparison of the platelet-rich plasma and the buffy coat methods, Transfusion, 30, pp. 634-638, (1990)
[6]  
Masse, Andreu, Angue, Et al., A multicenter study on the efficiency of white cell reduction by filtration of red cells, Transfusion, 31, pp. 792-797, (1991)
[7]  
Lutz, Dzik, Large-volume hemocytometer chamber for accurate counting of white cells in WBC-reduced platelets: validation and application for quality control of WBC-reduced platelets prepared by apheresis and filtration, Transfusion, 33, pp. 409-412, (1993)
[8]  
Dzik, Ragosta, Cusack, Flowcytometric method for counting very low numbers of leukocytes in platelet products, Vox Sang, 59, pp. 153-159, (1990)
[9]  
Anderson, Moroff, Hedberg, Et al., Storage of pooled leukodepleted platelet products (abstract), Transfusion, 32, (1992)
[10]  
Lovric, Schuller, Raftos, Wisdom, Filtered microaggregate-free erythrocyte concentrates with 35-day shelf life, Vox Sang, 41, pp. 6-10, (1981)