LONG-DURATION, LOW-FLOW SEVOFLURANE ANESTHESIA USING 2 CARBON-DIOXIDE ABSORBENTS - QUANTIFICATION OF DEGRADATION PRODUCTS IN THE CIRCUIT

被引:85
作者
BITO, H
IKEDA, K
机构
[1] Hamamatsu Univ. School of Medicine, Hamamatsu 431-31
关键词
ANESTHETIC SYSTEM; LOW-FLOW CIRCUIT; ANESTHETICS; VOLATILE; SEVOFLURANE; CARBON DIOXIDE; ABSORPTION; BARALYME SODA LIME;
D O I
10.1097/00000542-199408000-00011
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Sevoflurane reacts with soda lime, generating degradation products. The concentrations of sevoflurane degradation products in a low-flow circuit have been reported for anesthesia times of less than 5 h. In this study, sevoflurane degradation products generated during low-flow anesthesia exceeding 10 h were examined. Methods: Sixteen patients received sevoflurane anesthesia with a fresh gas flow rate of 1 l/min. In eight patients, soda lime was used as the CO2 absorbent; in the other eight patients, Baralyme was used. During anesthesia, the concentrations of degradation products in the circuit, the temperature of the CO2 absorbent, inspired and end-tidal sevoflurane concentrations, and the volume of CO2 eliminated by the patient were measured. Gas was sampled from the inspiratory limb of the circuit and analyzed by gas chromatography. Results: Two degradation products, CF2 = C(CF3) - O - CH2F (compound A) and CH3OCF2CH(CF3)OCH2F (compound B), were detected. In the soda lime group, the individual maximum concentration of compound A was 23.6 +/- 2.9 (12.0-37.4) ppm. In the Baralyme group, the concentration was 32.0 +/- 2.3 (23.5-41.3) ppm. The individual maximum concentration of compound A in the Baralyme group was significant higher than that in the soda lime group. Compound B was detected in two patients, reaching a maximum concentration of 0.2 ppm. The end-tidal sevoflurane concentration, temperature of the CO2 absorbent, and volume of CO2 eliminated by the patient were the same in both groups. Conclusions: The degradation products detected were at low concentrations in long-duration, low-flow anesthesia with sevoflurane. Baralyme produced higher concentrations of degradation products than soda lime.
引用
收藏
页码:340 / 345
页数:6
相关论文
共 11 条
  • [1] CLOSED-CIRCUIT ANESTHESIA WITH SEVOFLURANE IN HUMANS - EFFECTS ON RENAL AND HEPATIC-FUNCTION AND CONCENTRATIONS OF BREAKDOWN PRODUCTS WITH SODA LIME IN THE CIRCUIT
    BITO, H
    IKEDA, K
    [J]. ANESTHESIOLOGY, 1994, 80 (01) : 71 - 76
  • [2] QUANTIFICATION OF THE DEGRADATION PRODUCTS OF SEVOFLURANE IN 2 CO2 ABSORBANTS DURING LOW-FLOW ANESTHESIA IN SURGICAL PATIENTS
    FRINK, EJ
    MALAN, TP
    MORGAN, SE
    BROWN, EA
    MALCOMSON, M
    BROWN, BR
    [J]. ANESTHESIOLOGY, 1992, 77 (06) : 1064 - 1069
  • [3] HANAKI C, 1987, Hiroshima Journal of Medical Sciences, V36, P61
  • [4] Kudo M, 1990, Masui, V39, P39
  • [5] LIU J, 1991, ANESTH ANALG, V72, P785
  • [6] THE SAFETY OF SEVOFLURANE IN HUMANS
    MAZZE, RI
    [J]. ANESTHESIOLOGY, 1992, 77 (06) : 1062 - 1063
  • [7] REACTION OF SEVOFLURANE AND ITS DEGRADATION PRODUCTS WITH SODA LIME - TOXICITY OF THE BY-PRODUCTS
    MORIO, M
    FUJII, K
    SATOH, N
    IMAI, M
    KAWAKAMI, U
    MIZUNO, T
    KAWAI, Y
    OGASAWARA, Y
    TAMURA, T
    NEGISHI, A
    KUMAGAI, Y
    KAWAI, T
    [J]. ANESTHESIOLOGY, 1992, 77 (06) : 1155 - 1164
  • [8] SANJO Y, 1987, J CLIN MONITOR, V3, P235
  • [9] STABILITY OF SEVOFLURANE IN SODA LIME
    STRUM, DP
    JOHNSON, BH
    EGER, EI
    [J]. ANESTHESIOLOGY, 1987, 67 (05) : 779 - 781
  • [10] WALLIN RF, 1975, ANESTH ANALG, V54, P758