NONINVASIVE ASSESSMENT OF CARDIAC-OUTPUT IN CHILDREN USING IMPEDANCE CARDIOGRAPHY

被引:48
作者
BRADEN, DS
LEATHERBURY, L
TREIBER, FA
STRONG, WB
机构
[1] Section of Cardiology, Medical College of Georgia, Augusta, Ga
关键词
D O I
10.1016/0002-8703(90)90132-H
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study evaluated the effect of intracardiac shungting on the accuracy of thoracic bioimpedance-derived cardiac output determinations. Twenty-six patients, ranging in age from 3 months to 17 years, underwent cardiac catheterization during which simultaneous Fick and impedance measurements of cardiac output were obtained. The subjects were divided into three groups: 10 children with no intracardiac shunts, nine children with predominant left-to-right intracardiac shunts, and seven children with predominant right-to-left intracardiac shunts. Positive correlations between impedance and Fick-derived cardiac output determinations were obtained in the non-shunt group (r = 0.84), with lower correlations in the left-to-right shunt group (r = 0.70). In the right-to-left shunt group, the impedance derived cardiac output correlated with Fick pulmonary flow (r = 0.82), but the variability was unacceptably large. Although further study is needed, impedance cardiography appears to have validity as a methodology in pediatric critical care and cardiovascular health research. © 1990.
引用
收藏
页码:1166 / 1172
页数:7
相关论文
共 24 条
  • [1] RACIAL-DIFFERENCES IN STRESS-INDUCED CARDIOVASCULAR REACTIVITY AND HYPERTENSION - CURRENT STATUS AND SUBSTANTIVE ISSUES
    ANDERSON, NB
    [J]. PSYCHOLOGICAL BULLETIN, 1989, 105 (01) : 89 - 105
  • [2] COMPARISON OF MEASUREMENTS OF CARDIAC-OUTPUT BY BIOIMPEDANCE AND THERMODILUTION IN SEVERELY ILL SURGICAL PATIENTS
    APPEL, PL
    KRAM, HB
    MACKABEE, J
    FLEMING, AW
    SHOEMAKER, WC
    [J]. CRITICAL CARE MEDICINE, 1986, 14 (11) : 933 - 935
  • [3] CONTINUOUS NONINVASIVE REAL-TIME MONITORING OF STROKE VOLUME AND CARDIAC-OUTPUT BY THORACIC ELECTRICAL BIOIMPEDANCE
    BERNSTEIN, DP
    [J]. CRITICAL CARE MEDICINE, 1986, 14 (10) : 898 - 901
  • [4] CARDIAC-OUTPUT IN NEONATAL-PERIOD USING IMPEDANCE CARDIOGRAPHY
    COSTELOE, K
    STOCKS, J
    GODFREY, S
    MOHAPATRA, SN
    HILL, DW
    [J]. PEDIATRIC RESEARCH, 1977, 11 (12) : 1171 - 1177
  • [5] IMPEDANCE CARDIOGRAPHIC ASSESSMENT OF SYMPTOMATIC PATENT DUCTUS-ARTERIOSUS
    COTTON, RB
    LINDSTROM, DP
    OLSSON, T
    RIHA, M
    GRAHAM, TP
    SELSTAM, U
    CATTERTON, WZ
    [J]. JOURNAL OF PEDIATRICS, 1980, 96 (04) : 711 - 715
  • [6] MEASUREMENT OF CARDIAC-OUTPUT BY ELECTRICAL IMPEDANCE AT REST AND DURING EXERCISE
    DENNISTON, JC
    MAHER, JT
    REEVES, JT
    CRUZ, JC
    CYMERMAN, A
    GROVER, RF
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1976, 40 (01) : 91 - 95
  • [7] COMPARISON OF TRANS-THORACIC ELECTRICAL-IMPEDANCE AND THERMODILUTION METHODS FOR MEASURING CARDIAC-OUTPUT
    DONOVAN, KD
    DOBB, GJ
    WOODS, WPD
    HOCKINGS, BE
    [J]. CRITICAL CARE MEDICINE, 1986, 14 (12) : 1038 - 1044
  • [8] IMPEDANCE CARDIOGRAMS RELIABLY ESTIMATE BEAT-BY-BEAT CHANGES OF LEFT-VENTRICULAR STROKE VOLUME IN HUMANS
    EBERT, TJ
    ECKBERG, DL
    VETROVEC, GM
    COWLEY, MJ
    [J]. CARDIOVASCULAR RESEARCH, 1984, 18 (06) : 354 - 360
  • [9] GASTFRIEND RJ, 1986, AM SURGEON, V52, P636
  • [10] GOTSHALL R W, 1987, American Journal of Physiology, V253, pH1298