FERROCENE-ATTACHED L-LYSINE POLYMERS AS MEDIATORS FOR GLUCOSE-SENSING ELECTRODES

被引:25
作者
IIJIMA, S [1 ]
MIZUTANI, F [1 ]
YABUKI, S [1 ]
TANAKA, Y [1 ]
ASAI, M [1 ]
KATSURA, T [1 ]
HOSAKA, S [1 ]
IBONAI, M [1 ]
机构
[1] KOGAKUIN UNIV,FAC ENGN,DEPT IND CHEM,SHINJUKU KU,TOKYO 160,JAPAN
关键词
AMPEROMETRY; BIOSENSORS; ENZYMATIC METHODS; ENZYME ELECTRODES; FERROCENE; GLUCOSE; LYSINE POLYMERS; POLYMERIC MEDIATORS;
D O I
10.1016/0003-2670(93)85006-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two kinds of water-soluble polymers having ferrocenyl groups were prepared by the reactions of ferrocenoyl chloride with a homopolymer and a copolymer of L-lysine. The polymers acted as electron mediators between electrodes and the reduced form of glucose oxidase. Amperometric glucose-sensing electrodes were constructed by the simultaneous immobilization of each polymeric mediator and glucose oxidase near the surface of a glassy carbon electrode with a semipermeable membrane. The sensing-electrode using the ferrocene-attached L-lysine homopolymer was usable for the determination of glucose concentrations up to 6 mM.
引用
收藏
页码:483 / 487
页数:5
相关论文
共 18 条
[1]   SOME NITROGEN-CONTAINING FERROCENE DERIVATIVES [J].
ACTON, EM ;
SILVERSTEIN, RM .
JOURNAL OF ORGANIC CHEMISTRY, 1959, 24 (10) :1487-1490
[2]   ELECTRICAL COMMUNICATION BETWEEN REDOX CENTERS OF GLUCOSE-OXIDASE AND ELECTRODES VIA ELECTROSTATICALLY AND COVALENTLY BOUND REDOX POLYMERS [J].
DEGANI, Y ;
HELLER, A .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1989, 111 (06) :2357-2358
[3]   REDOX POLYMER-FILMS CONTAINING ENZYMES .1. A REDOX-CONDUCTING EPOXY CEMENT - SYNTHESIS, CHARACTERIZATION, AND ELECTROCATALYTIC OXIDATION OF HYDROQUINONE [J].
GREGG, BA ;
HELLER, A .
JOURNAL OF PHYSICAL CHEMISTRY, 1991, 95 (15) :5970-5975
[4]   CROSS-LINKED REDOX GELS CONTAINING GLUCOSE-OXIDASE FOR AMPEROMETRIC BIOSENSOR APPLICATIONS [J].
GREGG, BA ;
HELLER, A .
ANALYTICAL CHEMISTRY, 1990, 62 (03) :258-263
[5]   REDOX POLYMER-FILMS CONTAINING ENZYMES .2. GLUCOSE-OXIDASE CONTAINING ENZYME ELECTRODES [J].
GREGG, BA ;
HELLER, A .
JOURNAL OF PHYSICAL CHEMISTRY, 1991, 95 (15) :5976-5980
[6]   AMPEROMETRIC GLUCOSE SENSORS BASED ON FERROCENE-MODIFIED POLY(ETHYLENE OXIDE) AND GLUCOSE-OXIDASE [J].
HALE, PD ;
LAN, HL ;
BOGUSLAVSKY, LI ;
KARAN, HI ;
OKAMOTO, Y ;
SKOTHEIM, TA .
ANALYTICA CHIMICA ACTA, 1991, 251 (1-2) :121-128
[7]  
ICHIMURA K, 1984, J POLYM SCI POL CHEM, V22, P281
[8]   FERROCENE ATTACHED BOVINE SERUM-ALBUMIN AS A MEDIATOR BETWEEN GLUCOSE-OXIDASE AND AN ELECTRODE [J].
MIZUTANI, F ;
ASAI, M .
DENKI KAGAKU, 1988, 56 (12) :1100-1101
[9]   AN ENZYME ELECTRODE FOR L-LACTATE WITH A CHEMICALLY-AMPLIFIED RESPONSE [J].
MIZUTANI, F ;
YAMANAKA, T ;
TANABE, Y ;
TSUDA, K .
ANALYTICA CHIMICA ACTA, 1985, 177 :153-166
[10]  
MIZUTANI F, 1989, P MRS INT M ADV MATE, V14, P147