AREA-UNDER-THE-CURVE MONITORING OF CYCLOSPORINE THERAPY - PERFORMANCE OF DIFFERENT ASSAY-METHODS AND THEIR TARGET CONCENTRATIONS

被引:23
|
作者
GREVEL, J
NAPOLI, KL
GIBBONS, S
KAHAN, BD
机构
[1] UNIV TEXAS,SCH MED,DEPT SURG,DIV IMMUNOL,HOUSTON,TX 77030
[2] UNIV TEXAS,SCH MED,DEPT PHARMACOL,HOUSTON,TX 77030
关键词
Area under the curve; Cyclosporine therapy; Radioimmunoassay; Trough level monitoring;
D O I
10.1097/00007691-199001000-00003
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The measurement of areas under the concentration-time curve (AUC) was recently introduced as an alternative to trough level monitoring of cyclosporine therapy. The AUC is divided by the oral dosing interval to calculate an average concentration. All measurements are performed at clinical steady state. The initial evaluation of AUC monitoring showed advantages over trough level monitoring with concentrations of cyclosporine measured in serum by the polyclonal radioimmunoassay of Sandoz. This assay technique is no longer available and the following assays were performed in parallel during up to 173 AUC determinations in 51 consecutive renal transplant patients: Polyclonal fluorescence polarization immunoassay of Abbott in serum, specific and nonspecific monoclonal radioimmunoassays using 3H and 125I tracers in serum and whole blood, and high performance liquid chromatography in whole blood. Both trough levels and average concentrations at steady state measured by those different techniques were significantly correlated with the oral dose. The best correlation (r2 = 0.54) was shown by average concentrations measured in whole blood by the specific monoclonal radioimmunoassay of Sandoz (3H tracer). This monitoring technique was also associated with the smallest absolute error between repeated observations in the same patient while the oral dose rate remained the same or was changed. Both allegedly specific monoclonal radioimmunoassays (with 3H and 125I tracer) measured significantly higher concentrations than the liquid chromatography. The following target values for average steady state concentrations were calculated based on correlations of the new methods with the polyclonal radioimmunoassay in serum, for which a target of 200 ng/ml had been established: specific monoclonal radioimmunoassay in serum, 144 ng/ml; nonspecific monoclonal radioimmunoassay in serum, 331 ng/ml; fluorescence polarization immunoassay in serum, 233 ng/ml; liquid chromatography in whole blood, 272 ng/ml; specific monoclonal radioimmunoassay with 3H tracer in whole blood, 372 ng/ml; and specific monoclonal radioimmunoassay with 125I tracer in whole blood, 431 ng/ml. © 1990 Raven press, Ltd., New York.
引用
收藏
页码:8 / 15
页数:8
相关论文
共 50 条
  • [21] SPECIFIC MONOCLONAL RADIOIMMUNOASSAY AND FLUORESCENCE POLARIZATION IMMUNOASSAY FOR TROUGH CONCENTRATION AND AREA-UNDER-THE-CURVE MONITORING OF CYCLOSPORINE IN RENAL-TRANSPLANTATION
    LINDHOLM, A
    NAPOLI, K
    RUTZKY, L
    KAHAN, BD
    THERAPEUTIC DRUG MONITORING, 1992, 14 (04) : 292 - 300
  • [22] OPTIMUM NUMERICAL-INTEGRATION METHODS FOR ESTIMATION OF AREA-UNDER-THE-CURVE (AUC) AND AREA-UNDER-THE-MOMENT-CURVE (AUMC)
    PURVES, RD
    JOURNAL OF PHARMACOKINETICS AND BIOPHARMACEUTICS, 1992, 20 (03): : 211 - 226
  • [23] Isoniazid concentrations in hair and plasma area-under-the-curve exposure among children with tuberculosis
    Mave, Vidya
    Kinikar, Aarti
    Kagal, Anju
    Nimkar, Smita
    Koli, Hari
    Khwaja, Sultanat
    Bharadwaj, Renu
    Gerona, Roy
    Wen, Anita
    Ramachandran, Geetha
    Kumar, Hemanth
    Bacchetti, Peter
    Dooley, Kelly E.
    Gupte, Nikhil
    Gupta, Amita
    Gandhi, Monica
    PLOS ONE, 2017, 12 (12):
  • [24] Doing More With Less: Pragmatic Implementation of Vancomycin Area-Under-the-Curve (AUC) Monitoring
    Huang, Joanne
    Chan, Jeannie D.
    Nguyen, Thu
    Jain, Rupali
    Escobar, Zahra Kassamali
    JOURNAL OF PHARMACY PRACTICE, 2023, 36 (01) : 10 - 14
  • [25] Cyclosporine neoral monitoring and its correlation with the ''area under the curve''
    Sabbatiello, R
    Sgrosso, JL
    Schiavelli, R
    Castro, C
    Ahualli, L
    Pattin, M
    Vazquez, MC
    TRANSPLANTATION PROCEEDINGS, 1996, 28 (06) : 3378 - 3378
  • [26] Cyclosporine A monitoring: Abbreviated area under curve in children.
    DelloStrologo, L
    Campagnano, P
    Federici, G
    Rizzoni, G
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1997, 8 : A3165 - A3165
  • [27] Area-under-the-curve monitoring of prednisolone for dose optimization in a stable renal transplant population
    Potter, JM
    McWhinney, BC
    Sampson, L
    Hickman, PE
    THERAPEUTIC DRUG MONITORING, 2004, 26 (04) : 408 - 414
  • [29] Cyclosporine therapy monitored with abbreviated area under curve in nephrotic syndrome
    Stefano Rinaldi
    Antonella Sesto
    Paola Barsotti
    Tullio Faraggiana
    Francesco Sera
    Gianfranco Rizzoni
    Pediatric Nephrology, 2005, 20 : 25 - 29
  • [30] Cyclosporine therapy monitored with abbreviated area under curve in nephrotic syndrome
    Rinaldi, S
    Sesto, A
    Barsotti, P
    Faraggiana, T
    Sera, F
    Rizzoni, G
    PEDIATRIC NEPHROLOGY, 2005, 20 (01) : 25 - 29