AREA-UNDER-THE-CURVE MONITORING OF CYCLOSPORINE THERAPY - PERFORMANCE OF DIFFERENT ASSAY-METHODS AND THEIR TARGET CONCENTRATIONS

被引:23
|
作者
GREVEL, J
NAPOLI, KL
GIBBONS, S
KAHAN, BD
机构
[1] UNIV TEXAS,SCH MED,DEPT SURG,DIV IMMUNOL,HOUSTON,TX 77030
[2] UNIV TEXAS,SCH MED,DEPT PHARMACOL,HOUSTON,TX 77030
关键词
Area under the curve; Cyclosporine therapy; Radioimmunoassay; Trough level monitoring;
D O I
10.1097/00007691-199001000-00003
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The measurement of areas under the concentration-time curve (AUC) was recently introduced as an alternative to trough level monitoring of cyclosporine therapy. The AUC is divided by the oral dosing interval to calculate an average concentration. All measurements are performed at clinical steady state. The initial evaluation of AUC monitoring showed advantages over trough level monitoring with concentrations of cyclosporine measured in serum by the polyclonal radioimmunoassay of Sandoz. This assay technique is no longer available and the following assays were performed in parallel during up to 173 AUC determinations in 51 consecutive renal transplant patients: Polyclonal fluorescence polarization immunoassay of Abbott in serum, specific and nonspecific monoclonal radioimmunoassays using 3H and 125I tracers in serum and whole blood, and high performance liquid chromatography in whole blood. Both trough levels and average concentrations at steady state measured by those different techniques were significantly correlated with the oral dose. The best correlation (r2 = 0.54) was shown by average concentrations measured in whole blood by the specific monoclonal radioimmunoassay of Sandoz (3H tracer). This monitoring technique was also associated with the smallest absolute error between repeated observations in the same patient while the oral dose rate remained the same or was changed. Both allegedly specific monoclonal radioimmunoassays (with 3H and 125I tracer) measured significantly higher concentrations than the liquid chromatography. The following target values for average steady state concentrations were calculated based on correlations of the new methods with the polyclonal radioimmunoassay in serum, for which a target of 200 ng/ml had been established: specific monoclonal radioimmunoassay in serum, 144 ng/ml; nonspecific monoclonal radioimmunoassay in serum, 331 ng/ml; fluorescence polarization immunoassay in serum, 233 ng/ml; liquid chromatography in whole blood, 272 ng/ml; specific monoclonal radioimmunoassay with 3H tracer in whole blood, 372 ng/ml; and specific monoclonal radioimmunoassay with 125I tracer in whole blood, 431 ng/ml. © 1990 Raven press, Ltd., New York.
引用
收藏
页码:8 / 15
页数:8
相关论文
共 50 条
  • [11] COMPARISON OF ASSAY-METHODS FOR USE WITH A NEW STRATEGY FOR CYCLOSPORINE MONITORING
    NAPOLI, KL
    GREVEL, J
    ARMOUR, C
    CLINICAL CHEMISTRY, 1989, 35 (06) : 1186 - 1186
  • [12] Abbreviated pharmacokinetic profiles in area-under-the-curve monitoring of cyclosporine therapy in de novo renal transplant patients treated with Sandimmune or Neoral
    Marsh, CL
    THERAPEUTIC DRUG MONITORING, 1999, 21 (01) : 27 - 34
  • [13] FAILURE TO PREDICT CYCLOSPORINE AREA-UNDER-THE-CURVE USING A LIMITED SAMPLING STRATEGY
    GASPARI, F
    RUGGENENTI, P
    TORRE, L
    BERTOCCHI, C
    REMUZZI, G
    PERICO, N
    KIDNEY INTERNATIONAL, 1993, 44 (02) : 436 - 439
  • [14] AREA UNDER THE CURVE MONITORING OF CYCLOSPORINE THERAPY - THE EARLY POSTTRANSPLANT PERIOD
    GREVEL, J
    KAHAN, BD
    THERAPEUTIC DRUG MONITORING, 1991, 13 (02) : 89 - 95
  • [15] CYCLOSPORINE BLOOD-CONCENTRATIONS DETERMINED BY SPECIFIC VERSUS NONSPECIFIC ASSAY-METHODS
    BLYDEN, GT
    FRANKLIN, C
    CHO, SI
    KAPLAN, MM
    HIRSCH, CA
    GREENBLATT, DJ
    JOURNAL OF CLINICAL PHARMACOLOGY, 1986, 26 (05): : 367 - 371
  • [16] ABBREVIATED 3-POINT KINETIC PROFILE IN THE 12-HOUR AREA-UNDER-THE-CURVE FOR PHARMACOKINETIC MONITORING OF CYCLOSPORINE
    SERINO, F
    CITTERIO, F
    POZZETTO, U
    GREVEL, J
    CASTAGNETO, M
    TRANSPLANTATION PROCEEDINGS, 1994, 26 (05) : 2807 - 2808
  • [17] Abbreviated tacrolimus area-under-the-curve monitoring for renal transplant recipients
    Wong, KM
    Shek, CC
    Chau, KF
    Li, CS
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2000, 35 (04) : 660 - 666
  • [18] Comparison and validation of limited sampling equations for cyclosporine area-under-the-curve monitoring calculations in pediatric renal transplant recipients
    Charlebois, JE
    Lum, BL
    Cooney, GF
    Mochon, M
    Kaiser, BA
    THERAPEUTIC DRUG MONITORING, 1997, 19 (03) : 277 - 280
  • [19] An abbreviated area-under-the-curve monitoring for tacrolimus in patients with liver transplants
    Ku, YM
    Min, DI
    THERAPEUTIC DRUG MONITORING, 1998, 20 (02) : 219 - 223
  • [20] ABBREVIATED PHARMACOKINETIC (PK) PROFILES IN AREA-UNDER-THE-CURVE (AUC) MONITORING OF CYCLOSPORINE (CSA) THERAPY IN DE-NOVO RENAL-TRANSPLANT PATIENTS
    MARSH, C
    PRUETT, T
    MIN, D
    THOMPSON, J
    WAID, CT
    BUNKE, CM
    KLEIN, JB
    PESCOVITZ, MD
    POLLAK, R
    VASQUEZ, E
    BARONE, G
    WOMBOLT, D
    STINSON, J
    WONG, R
    CHOC, MG
    HWANG, DS
    CHANG, CT
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1995, 6 (03): : 1103 - 1103