AREA-UNDER-THE-CURVE MONITORING OF CYCLOSPORINE THERAPY - PERFORMANCE OF DIFFERENT ASSAY-METHODS AND THEIR TARGET CONCENTRATIONS

被引:23
|
作者
GREVEL, J
NAPOLI, KL
GIBBONS, S
KAHAN, BD
机构
[1] UNIV TEXAS,SCH MED,DEPT SURG,DIV IMMUNOL,HOUSTON,TX 77030
[2] UNIV TEXAS,SCH MED,DEPT PHARMACOL,HOUSTON,TX 77030
关键词
Area under the curve; Cyclosporine therapy; Radioimmunoassay; Trough level monitoring;
D O I
10.1097/00007691-199001000-00003
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The measurement of areas under the concentration-time curve (AUC) was recently introduced as an alternative to trough level monitoring of cyclosporine therapy. The AUC is divided by the oral dosing interval to calculate an average concentration. All measurements are performed at clinical steady state. The initial evaluation of AUC monitoring showed advantages over trough level monitoring with concentrations of cyclosporine measured in serum by the polyclonal radioimmunoassay of Sandoz. This assay technique is no longer available and the following assays were performed in parallel during up to 173 AUC determinations in 51 consecutive renal transplant patients: Polyclonal fluorescence polarization immunoassay of Abbott in serum, specific and nonspecific monoclonal radioimmunoassays using 3H and 125I tracers in serum and whole blood, and high performance liquid chromatography in whole blood. Both trough levels and average concentrations at steady state measured by those different techniques were significantly correlated with the oral dose. The best correlation (r2 = 0.54) was shown by average concentrations measured in whole blood by the specific monoclonal radioimmunoassay of Sandoz (3H tracer). This monitoring technique was also associated with the smallest absolute error between repeated observations in the same patient while the oral dose rate remained the same or was changed. Both allegedly specific monoclonal radioimmunoassays (with 3H and 125I tracer) measured significantly higher concentrations than the liquid chromatography. The following target values for average steady state concentrations were calculated based on correlations of the new methods with the polyclonal radioimmunoassay in serum, for which a target of 200 ng/ml had been established: specific monoclonal radioimmunoassay in serum, 144 ng/ml; nonspecific monoclonal radioimmunoassay in serum, 331 ng/ml; fluorescence polarization immunoassay in serum, 233 ng/ml; liquid chromatography in whole blood, 272 ng/ml; specific monoclonal radioimmunoassay with 3H tracer in whole blood, 372 ng/ml; and specific monoclonal radioimmunoassay with 125I tracer in whole blood, 431 ng/ml. © 1990 Raven press, Ltd., New York.
引用
收藏
页码:8 / 15
页数:8
相关论文
共 50 条
  • [1] COMPARISON OF 3 METHODS FOR CYCLOSPORINE AREA-UNDER-THE-CURVE MONITORING CALCULATIONS
    DALERE, GM
    LUM, BL
    COONEY, GF
    WONGCHIN, M
    THERAPEUTIC DRUG MONITORING, 1995, 17 (03) : 305 - 307
  • [2] CHALLENGES IN CYCLOSPORINE THERAPY - THE ROLE OF THERAPEUTIC MONITORING BY AREA-UNDER-THE-CURVE MONITORING
    KAHAN, BD
    WELSH, M
    RUTZKY, LP
    THERAPEUTIC DRUG MONITORING, 1995, 17 (06) : 621 - 624
  • [3] ABBREVIATED KINETIC PROFILES IN AREA-UNDER-THE-CURVE MONITORING OF CYCLOSPORINE THERAPY
    GREVEL, J
    KAHAN, BD
    CLINICAL CHEMISTRY, 1991, 37 (11) : 1905 - 1908
  • [4] Abbreviated kinetic profiles in area-under-the-curve monitoring of cyclosporine therapy - Technical Note
    Gaspari, F
    Perico, N
    Signorini, O
    Caruso, R
    Remuzzi, G
    KIDNEY INTERNATIONAL, 1998, 54 (06) : 2146 - 2150
  • [5] EFFICACY OF AREA-UNDER-THE-CURVE CYCLOSPORINE MONITORING IN RENAL-TRANSPLANTATION
    MEYER, MM
    MUNAR, M
    UDEAJA, J
    BENNETT, W
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1993, 4 (06): : 1306 - 1315
  • [6] Abbreviated area-under-the-curve strategy for monitoring cyclosporine microemulsion therapy in immediate posttransplant period
    Amante, AJ
    Kahan, BD
    CLINICAL CHEMISTRY, 1996, 42 (08) : 1294 - 1296
  • [7] MONITORING CYCLOSPORINE CONCENTRATIONS IN MARROW TRANSPLANT RECIPIENTS - COMPARISON OF 2 ASSAY-METHODS
    YEE, GC
    KENNEDY, MS
    GMUR, DJ
    SELF, SG
    DEEG, HJ
    BONE MARROW TRANSPLANTATION, 1987, 1 (03) : 289 - 295
  • [8] CYCLOSPORINE PHARMACOKINETICS IN UREMIC PATIENTS - INFLUENCE OF DIFFERENT ASSAY-METHODS
    REYNOLDS, KL
    GREVEL, J
    GIBBONS, SY
    WELSH, MS
    RUTZKY, LP
    KAHAN, BD
    TRANSPLANTATION PROCEEDINGS, 1988, 20 (02) : 462 - 465
  • [9] CYCLOSPORINE BLOOD-CONCENTRATIONS DETERMINED BY DIFFERENT ASSAY-METHODS IN HEART-TRANSPLANT PATIENTS
    ZYLBERKATZ, E
    GRANIT, L
    THERAPEUTIC DRUG MONITORING, 1989, 11 (05) : 592 - 597
  • [10] ASSAY-METHODS FOR CYCLOSPORINE MONITORING FOLLOWING LIVER-TRANSPLANTATION
    HAVEN, MC
    SOBESKI, LM
    EARL, RA
    MARKIN, RS
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 1990, 4 (02) : 150 - 156