Frankfort horizontal plane is an appropriate three-dimensinal reference in the evaluation of clinical and skeletal cant

被引:16
|
作者
Oh, Suseok [1 ]
Ahn, Jaemyung [1 ]
Nam, Ki-Uk [1 ]
Paeng, Jun-Young [2 ]
Hong, Jongrak [1 ]
机构
[1] Sungkyunkwan Univ, Samsung Med Ctr, Sch Med, Dept Oral & Maxillofacial Surg, 81 Irwon Ro, Seoul 135710, South Korea
[2] Kyungpook Natl Univ, Sch Dent, Dept Oral & Maxillofacial Surg, Daegu, South Korea
关键词
Facial asymmetry; Cephalometry; Three-dimensional computed tomography;
D O I
10.5125/jkaoms.2013.39.2.71
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: In three-dimensional computed tomography (3D-CT), the cant is evaluated by measuring the distance between the reference plane (or line) and the tooth. The purpose of this study was to determine the horizontal skeletal reference plane that showed the greatest correlation with clinical evaluation. Materials and Methods: The subjects were 15 patients who closed their eyes during the CT image taking process. The menton points of all patients deviated by more than 3 mm. In the first evaluation, clinical cant was measured. The distance from the inner canthus to the ipsilateral canine tip and the distance from the eyelid to the ipsilateral first molar were obtained. The distance between the left and right sides was also measured. In the second evaluation, skeletal cant was measured. Six reference planes and one line were used for the evaluation of occlusal cant: 1) FH plane R:Or. R - Or. L Po.R; 2) FH plane L:Or. R - Or. L - Po.L; 3) F. Ovale plane R:Rt.F. Ovale - Lt. F. Ovale - Or. R; 4) F. Ovale plane L:Rt.F. Ovale - Lt. F. Ovale - Or. L; 5) FZS plane R:Rt. FZS - Lt. FZS - Po. R; 6) FZS plane R:Rt. FZS - Lt. FZS - Po.L, and; 7) FZS line:Rt. FZS - Lt. FZS. Results: The clinical and skeletal cants were compared using linear regression analysis. The FH plane R, FH plane L, and FZS line showed the highest correlation (P<0.05). Conclusion: The FH plane R and FH plane L are the most appropriate horizontal reference plane in evaluation of occlusal cant on 3D-CT.
引用
收藏
页码:71 / 76
页数:6
相关论文
共 2 条
  • [1] Effects of Changes in the Frankfort Horizontal Plane Definition on the Three-Dimensional Cephalometric Evaluation of Symmetry
    Mangal, Utkarsh
    Hwang, Jae Joon
    Jo, Heon
    Lee, Sung Min
    Jung, Yun-Hoa
    Cho, Bong-Hae
    Cha, Jung-Yul
    Choi, Sung-Hwan
    APPLIED SCIENCES-BASEL, 2020, 10 (22): : 1 - 12
  • [2] Three-Dimensional Cephalometric Landmarking and Frankfort Horizontal Plane Construction: Reproducibility of Conventional and Novel Landmarks
    Dot, Gauthier
    Rafflenbeul, Frederic
    Kerbrat, Adeline
    Rouch, Philippe
    Gajny, Laurent
    Schouman, Thomas
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (22)