STUDIES ON THE COULOMETRIC DETERMINATION OF URANIUM AND PLUTONIUM EMPLOYING A GRAPHITE ELECTRODE

被引:12
作者
SHARMA, HS [1 ]
MANOLKAR, RB [1 ]
KAMAT, JV [1 ]
MARATHE, SG [1 ]
机构
[1] BHABHA ATOM RES CTR,DIV FUEL CHEM,BOMBAY 400085,INDIA
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1993年 / 347卷 / 12期
关键词
D O I
10.1007/BF00324240
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Graphite has been employed as a working electrode in the controlled potential coulometric determination of uranium and plutonium. The couples U(VI)/U(IV) and Pu(IV)/Pu(III) employed for analysis have diverse redox potentials and commonly the working electrodes employed are mercury and platinum. A graphite electrode in the shape of a beaker showed satisfactory performance for the quantitative reduction of U(VI) to U(IV) and Pu(IV) to Pu(III) and also for quantitative oxidation of Pu(III) to Pu(IV). Studies on the levels of the background current, blank values and their reproducible behaviour in acid media have been carried out with a view to achieve good precision and accuracy. A software-based predictive evaluation technique of end-point charge has been investigated. The results have shown that the graphite electrode can be used for the determination of both uranium and plutonium in the presence of each other with a precision and accuracy of better than +/- 0.5%.
引用
收藏
页码:486 / 490
页数:5
相关论文
共 25 条
[1]   POTENTIOMETRIC DETERMINATION OF PLUTONIUM BY ARGENTIC OXIDATION FERROUS REDUCTION AND DICHROMATE TITRATION [J].
DRUMMOND, JL ;
GRANT, RA .
TALANTA, 1966, 13 (03) :477-&
[2]  
DRYHURST G, 1984, LABORATORY TECHNIQUE, P289
[3]  
EBERLE AR, 1972, USAEC NBL252
[4]   CONTROLLED POTENTIAL COULOMETRY - APPLICATION OF A SECONDARY REACTION TO DETERMINATION OF PLUTONIUM AND URANIUM AT A SOLID ELECTRODE [J].
FARDON, JB ;
MCGOWAN, IR .
TALANTA, 1972, 19 (11) :1321-&
[5]  
Gopinath N., 1989, B ELECTROCHEM, V5, P805
[6]  
HARRAR JE, 1975, ELECTROANALYTICAL CH, V8
[7]   COULOMETRIC MICROTITRATION OF ARSENIC(III) AND ISONIAZID USING A VITREOUS CARBON GENERATING ELECTRODE [J].
JENNINGS, VJ ;
DODSON, A ;
HARRISON, A .
ANALYST, 1974, 99 (1176) :145-148
[8]   COULOMETRIC TITRATION OF POTASSIUM HYDROGEN PHTHALATE IN A NON-AQUEOUS SOLUTION, WITH A VITREOUS CARBON ANODE [J].
JENNINGS, VJ ;
DODSON, A ;
TEDDS, G .
TALANTA, 1974, 21 (06) :622-623
[9]   USE OF VITREOUS CARBON AS A WORKING ELECTRODE IN COULOMETRIC TITRATION OF POTASSIUM HYDROGEN PHTHALATE [J].
JENNINGS, VJ ;
DODSON, A ;
TEDDS, G .
TALANTA, 1973, 20 (07) :681-684
[10]   USE OF VITREOUS CARBON AND CARBON-FIBER ELECTRODES FOR COULOMETRIC GENERATION OF IODINE [J].
JENNINGS, VJ ;
DODSON, A ;
EASTMAN, RJ .
ANALYTICA CHIMICA ACTA, 1975, 76 (01) :143-147