Accuracy of Positron Emission Tomography as a Diagnostic Tool for Lead Endocarditis: Design of the Prospective Multicentre ENDOTEP Study

被引:4
作者
Amraoui, Sana [1 ]
Tlili, Ghoufrane [2 ]
Hindie, Elif [2 ]
Perez, Paul [3 ]
Peuchant, Olivia
Bordenave, Laurence [2 ]
Bordachar, Pierre [1 ]
机构
[1] Bordeaux Univ, Cardiol Haut Leveque Hosp, LIRYC Inst, INSERM,U1045, Bordeaux, France
[2] Bordeaux Univ, Nucl Med Ctr, Bordeaux, France
[3] Bordeaux Univ, ISPED Ctr, Bordeaux, France
关键词
F-18-FDG-PET/CT scanning; diagnostic accuracy; lead endocarditis; pacemaker infection; septic emboli;
D O I
10.15420/ecr.2016:6:2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Rates of pacemaker implantation are steadily increasing and as patients are living longer, endovenous leads remain implanted for an extended period of time thereby increasing the risk of cardiac implantable electronic device (CIED) infection. Investigating fever of unknown origin in patients with implanted pacemakers can be challenging. Recently, F-18-fluorodeoxyglucose positron emission tomography/computerised tomography (F-18-FDG-PET/CT) scanning has been used as a diagnostic tool for lead endocarditis in small studies. Objectives: ENDOTEP is a prospective and multicentre study designed to evaluate the accuracy of F-18-FDG-PET/CT scanning in the diagnosis of lead endocarditis. Methods: A total of 250 patients referred for pacemaker extraction due to suspicion of an infected device will be prospectively enrolled in six French regional centres for investigation and treatment of CIED infection. F-18-FDG-PET/CT scanning (index test) will be performed in each patient in the 48 hours preceding lead extraction. Bacteriological cultures (reference standard) will assess the presence of lead endocarditis, blind to F-18-FDG-PET/CT results. Enrolment started in June 2015 and is expected to end by June 2017. The primary objective will be to establish the sensitivity of the F-18-FDG-PET/CT scan for lead endocarditis. Secondary objectives will include other accuracy parameters, inter-observer agreement in the interpretation of F-18-FDG-PET/CT scanning, the influence of previous antibiotic therapy on F-18-FDG-PET/CT diagnostic accuracy and assessment of septic emboli associated to lead endocarditis. Conclusion: The ENDOTEP study will examine the ability of F-18-FDG-PET/CT scanning to avoid possible false-positive results, as is common using the current usual diagnostic strategy and may lead to unnecessary extraction of implants in patients with suspected lead infection.
引用
收藏
页码:25 / 28
页数:4
相关论文
共 23 条
[1]   Contribution of PET Imaging to the Diagnosis of Septic Embolism in Patients With Pacing Lead Endocarditis [J].
Amraoui, Sana ;
Tlili, Ghoufrane ;
Sohal, Manav ;
Berte, Benjamin ;
Hindie, Elif ;
Ritter, Philippe ;
Ploux, Sylvain ;
Denis, Arnaud ;
Derval, Nicolas ;
Rinaldi, Christopher A. ;
Cazanave, Charles ;
Jais, Pierre ;
Haissaguerre, Michel ;
Bordenave, Laurence ;
Bordachar, Pierre .
JACC-CARDIOVASCULAR IMAGING, 2016, 9 (03) :283-290
[2]   PET scan in suspected but unproven pacemaker endocarditis [J].
Amraoui, Sana ;
Texier-Maugein, Jeannette ;
Bordachar, Pierre .
ARCHIVES OF CARDIOVASCULAR DISEASES, 2012, 105 (02) :125-126
[3]   Clinical Characteristics and Outcome of Infective Endocarditis Involving Implantable Cardiac Devices [J].
Athan, Eugene ;
Chu, Vivian H. ;
Tattevin, Pierre ;
Selton-Suty, Christine ;
Jones, Phillip ;
Naber, Christoph ;
Miro, Jose M. ;
Ninot, Salvador ;
Fernandez-Hidalgo, Nuria ;
Durante-Mangoni, Emanuele ;
Spelman, Denis ;
Hoen, Bruno ;
Lejko-Zupanc, Tatjana ;
Cecchi, Enrico ;
Thuny, Franck ;
Hannan, Margaret M. ;
Pappas, Paul ;
Henry, Margaret ;
Fowler, Vance G., Jr. ;
Crowley, Anna Lisa ;
Wang, Andrew .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2012, 307 (16) :1727-1735
[4]   Risk Factors for Mortality in Patients With Cardiac Device-Related Infection [J].
Baman, Timir S. ;
Gupta, Sanjaya K. ;
Valle, Javier A. ;
Yamada, Elina .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2009, 2 (02) :129-134
[5]   Extraction of Old Pacemaker or Cardioverter-Defibrillator Leads by Laser Sheath Versus Femoral Approach [J].
Bordachar, Pierre ;
Defaye, Pascal ;
Peyrouse, Eric ;
Boveda, Serge ;
Mokrani, Bilel ;
Marquie, Christelle ;
Barandon, Laurent ;
Fossaert, Emilie Marcant ;
Garrigue, Stephane ;
Reuter, Sylvain ;
Laborderie, Julien ;
Marijon, Eloi ;
Deharo, Jean-Claude ;
Jacon, Peggy ;
Kacet, Salem ;
Ploux, Sylvain ;
Deplagne, Antoine ;
Haissaguerre, Michel ;
Clementy, Jacques ;
Ritter, Philippe ;
Klug, Didier .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2010, 3 (04) :319-323
[6]   Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD initiative [J].
Bossuyt, PM ;
Reitsma, JB ;
Bruns, DE ;
Gatsonis, CA ;
Glasziou, PP ;
Irwig, LM ;
Lijmer, JG ;
Moher, D ;
Rennie, D ;
de Vet, HCW .
CLINICAL CHEMISTRY, 2003, 49 (01) :1-6
[7]   Diagnostic yield of FDG positron-emission tomography/computed tomography in patients with CEID infection: a pilot study [J].
Cautela, Jennifer ;
Alessandrini, Stephane ;
Cammilleri, Serge ;
Giorgi, Roch ;
Richet, Herve ;
Casalta, Jean-Paul ;
Habib, Gilbert ;
Raoult, Didier ;
Mundler, Olivier ;
Deharo, Jean-Claude .
EUROPACE, 2013, 15 (02) :252-257
[8]   Promising role of 18-F-fluoro-D-deoxyglucose positron emission tomography in clinical infectious diseases [J].
De Winter, F ;
Vogelaers, D ;
Gemmel, F ;
Dierckx, RA .
EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2002, 21 (04) :247-257
[9]   NEW CRITERIA FOR DIAGNOSIS OF INFECTIVE ENDOCARDITIS - UTILIZATION OF SPECIFIC ECHOCARDIOGRAPHIC FINDINGS [J].
DURACK, DT ;
LUKES, AS ;
BRIGHT, DK ;
ALBERTS, MJ ;
BASHORE, TM ;
COREY, GR ;
DOUGLAS, JM ;
GRAY, L ;
HARRELL, FE ;
HARRISON, JK ;
HEINLE, SA ;
MORRIS, A ;
KISSLO, JA ;
NICELY, LM ;
OLDHAM, N ;
PENNING, LM ;
SEXTON, DJ ;
TOWNS, M ;
WAUGH, RA .
AMERICAN JOURNAL OF MEDICINE, 1994, 96 (03) :200-209
[10]   Accuracy of Swabs, Tissue Specimens, and Lead Samples in Diagnosis of Cardiac Rhythm Management Device Infections [J].
Golzio, Pier-Giorgio ;
Vinci, Melissa ;
Anselmino, Matteo ;
Comoglio, Chiara ;
Rinaldi, Mauro ;
Trevi, Gian P. ;
Bongiorni, Maria Grazia .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 :S76-S80