A FAST AND ACCURATE ALGORITHM FOR VOLUME DETERMINATION IN MRI

被引:36
|
作者
PECK, DJ
WINDHAM, JP
SOLTANIANZADEH, H
ROEBUCK, JR
机构
[1] Department of Diagnostic Radiology and Medical Imaging, Henry Ford Hospital, Detroit
关键词
MAGNETIC RESONANCE IMAGING (MRI); IMAGE PROCESSING; VOLUME DETERMINATION; PARTIAL VOLUME;
D O I
10.1118/1.596851
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The determination of volumes in clinical MRI studies are prohibitive because of the time required to compute an accurate volume. Techniques that speed up the calculation are prone to large errors which make most impractical for an accurate diagnosis. A linear filter, called the eigenimage filter, has been developed that separates a desired feature from other features which interfere with its observation in an image. Using the images produced by this technique (eigenimages), the amount of operator interaction required to calculate volumes are significantly reduced. The technique also has the ability to correct for partial volume averaging effects and as a result a more accurate volume can be determined. The technique was applied to a computer simulation and two phantom studies. The time required to calculate the volume was less than 1 min per slice and the errors in accuracy and reproducibility were less than 2% for all studies.
引用
收藏
页码:599 / 605
页数:7
相关论文
共 50 条
  • [1] Dynamic Windowing Algorithm for the Fast and Accurate Determination of Luminescence Lifetimes
    Collier, Bradley B.
    McShane, Michael J.
    ANALYTICAL CHEMISTRY, 2012, 84 (11) : 4725 - 4731
  • [2] Fast and Accurate Volume Data Curvature Determination using GPGPU Computation
    Hauenstein, Jacob D.
    Newman, Timothy S.
    ACMSE '18: PROCEEDINGS OF THE ACMSE 2018 CONFERENCE, 2018,
  • [3] PDT in intracerebral glioma: Accurate and objective tumour volume determination using MRI
    Gibbs, P
    Buckley, DL
    Blackband, SJ
    Horsman, A
    QUANTITATIVE IMAGING IN ONCOLOGY: 19TH L H GRAY CONFERENCE, 1996, : 44 - 46
  • [4] NOVIFAST: A Fast Algorithm for Accurate and Precise VFA MRI T1 Mapping
    Ramos-Llorden, Gabriel
    Vegas-Sanchez-Ferrero, Gonzalo
    Bjork, Marcus
    Vanhevel, Floris
    Parizel, Paul M.
    Estepar, Raul San Jose
    den Dekker, Arnold J.
    Sijbers, Jan
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (11) : 2414 - 2427
  • [5] A Fast & Accurate Non-Iterative Algorithm for Regularized Non-Cartesian MRI
    Kashyap, Satyananda
    Jacob, Mathews
    2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 265 - 268
  • [6] An automatic segmentation algorithm for accurate functional volume determination in radiotherapy treatment planning
    Hatt, M.
    Boussion, N.
    Roux, C.
    Pradier, O.
    Le Rest, C. Cheze
    Visvikis, D.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S189 - S190
  • [7] BrainLossNet: a fast, accurate and robust method to estimate brain volume loss from longitudinal MRI
    Opfer, Roland
    Kruger, Julia
    Buddenkotte, Thomas
    Spies, Lothar
    Behrendt, Finn
    Schippling, Sven
    Buchert, Ralph
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2024, 19 (09) : 1763 - 1771
  • [8] FRACTALS - A FAST, ACCURATE AND ILLUMINATING ALGORITHM
    BELL, SBM
    IMAGE AND VISION COMPUTING, 1995, 13 (04) : 253 - 257
  • [9] An accurate algorithm for fast frequency warping
    Caporale, Salvatore
    De Marchi, Luca
    Speciale, Nicolo
    2007 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1-11, 2007, : 1811 - 1814
  • [10] A Fast Volume Integral Equation Solver With Linear Basis Functions for the Accurate Computation of EM Fields in MRI
    Georgakis, Ioannis P.
    Giannakopoulos, Ilias I.
    Litsarev, Mikhail S.
    Polimeridis, Athanasios G.
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2021, 69 (07) : 4020 - 4032