POLYMERIC MEMBRANE ION-SELECTIVE ELECTRODES TO CERTAIN TYPES OF DRUGS

被引:0
|
作者
BOUKLOUZE, AA [1 ]
ELJAMMAL, A [1 ]
PATRIARCHE, GJ [1 ]
机构
[1] UNIV LIBRE BRUXELLES,INST PHARM,CAMPUS PLAINE,CP 205-6,BLVD TRIOMPHE,B-1050 BRUSSELS,BELGIUM
关键词
MODIFIED ELECTRODE; DIRECT POTENTIOMETRY; PVC MEMBRANE; PHOSPHOTUNGSTIC ACID; SULFATE; MULTICENTRIC CLINICAL STUDIES;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The construction and performance of ion-selective membrane electrode for neuroleptic tranquilizers by coating a graphite rod with a film of polyvinylchloride plasticized with a mixture of dioctylphtalate-nitrobenzene and incorporated by the phosphotungstate as counter-ion is described. The electrode exhibites a Nernstian response in the range of pH 3 to 4 for the fluphenazine, between pH 3.5 to 5.5 for the methixene and pH 5.1 to 6.3 for the dibenzepine. The ion-selective electrode slopes were into the range 53-55 mV per concentration decade over 10(-3) - 10(-6) M. Selectivity coefficients were determined for organic substances containing the pyrrolidin, piperazin and piperidin. Dibenzo compounds present a certain degree of interferences but the benzodiazepins family do not interfere. Direct potentiometry is used to determine these compounds in pharmaceutical preparation with accurate results.
引用
收藏
页码:27 / 30
页数:4
相关论文
共 50 条
  • [1] SOLVENT POLYMERIC MEMBRANE ION-SELECTIVE ELECTRODES
    THOMAS, JDR
    ANALYTICA CHIMICA ACTA, 1986, 180 : 289 - 297
  • [2] Electrochemically Switchable Polymeric Membrane Ion-Selective Electrodes
    Zdrachek, Elena
    Bakker, Eric
    ANALYTICAL CHEMISTRY, 2018, 90 (12) : 7591 - 7599
  • [3] Anti-fouling polymeric membrane ion-selective electrodes
    Qi, Longbin
    Liang, Rongning
    Jiang, Tianjia
    Qin, Wei
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2022, 150
  • [4] Enhancing ion-selective polymeric membrane electrodes by instrumental control
    Bakker, Eric
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2014, 53 : 98 - 105
  • [5] ION-SELECTIVE MEMBRANE ELECTRODES
    VALLON, JJ
    LYON PHARMACEUTIQUE, 1975, 26 (05): : 487 - 500
  • [6] DETERMINATION OF SULFA-DRUGS WITH ION-SELECTIVE MEMBRANE ELECTRODES
    IONESCU, M
    CILIANU, S
    BUNACIU, AA
    COSOFRET, VV
    TALANTA, 1981, 28 (06) : 383 - 387
  • [7] Polymeric membrane ion-selective electrodes based on molecular asterisk ionophores
    Johnson, RD
    Pinchart, A
    Badr, IHA
    Gingras, M
    Bachas, LG
    ELECTROANALYSIS, 2002, 14 (19-20) : 1419 - 1425
  • [8] ION-SELECTIVE ELECTRODES FOR BASIC DRUGS
    CUNNINGHAM, L
    FREISER, H
    ANALYTICA CHIMICA ACTA, 1982, 139 (JUL) : 97 - 103
  • [9] Ion-selective membrane electrodes: Membrane configuration
    Stefan, RI
    AboulEnein, HY
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 1997, 25 (02) : 169 - 173
  • [10] ION-SELECTIVE MEMBRANE ELECTRODES IN THE ANALYSIS OF INORGANIC DRUGS .1.
    IONESCU, M
    COSOFRET, VV
    REVISTA DE CHIMIE, 1980, 31 (10): : 1005 - 1009