Sound Level Exposure of High-Risk Infants in Different Environmental Conditions

被引:54
作者
Byers, Jacqueline F. [1 ]
Waugh, W. Randolph [2 ]
Lowman, Linda B. [2 ]
机构
[1] Univ Cent Florida, Nursing, Orlando, FL 32816 USA
[2] Arnold Palmer Hosp Children & Women, NICU, Orlando, FL USA
来源
NEONATAL NETWORK | 2006年 / 25卷 / 01期
关键词
D O I
10.1891/0730-0832.25.1.25
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Purposes: To provide descriptive information about the sound levels to which high-risk infants are exposed in various actual environmental conditions in the NICU, including the impact of physical renovation on sound levels, and to assess the contributions of various types of equipment, alarms, and activities to sound levels in simulated conditions in the NICU. Design: Descriptive and comparative design. Sample: Convenience sample of 134 infants at a southeastern quarternary children's hospital. Main Outcome Variable: A-weighted decibel (dBA) sound levels under various actual and simulated environmental conditions. Results: The renovated NICU was, on average, 4-6 dBA quieter across all environmental conditions than a comparable nonrenovated room, representing a significant sound level reduction. Sound levels remained above consensus recommendations despite physical redesign and staff training. Respiratory therapy equipment, alarms, staff talking, and infant fussiness contributed to higher sound levels. Conclusion: Evidence-based sound-reducing strategies are proposed. Findings were used to plan environment management as part of a developmental, family-centered care, performance improvement program and in new NICU planning.
引用
收藏
页码:25 / 32
页数:8
相关论文
共 27 条
[1]  
Aita Marilyn, 2003, Intensive Crit Care Nurs, V19, P109, DOI 10.1016/S0964-3397(03)00023-5
[2]  
ALLEN M, 2002, RECOMMENDED STANDARD
[3]   INDIVIDUALIZED DEVELOPMENTAL CARE FOR THE VERY-LOW-BIRTH-WEIGHT PRETERM INFANT - MEDICAL AND NEUROFUNCTIONAL EFFECTS [J].
ALS, H ;
LAWHON, G ;
DUFFY, FH ;
MCANULTY, GB ;
GIBESGROSSMAN, R ;
BLICKMAN, JG .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1994, 272 (11) :853-858
[4]  
Als Heidelise, 1998, Current Opinion in Pediatrics, V10, P138, DOI 10.1097/00008480-199804000-00004
[5]   Developmental care teams in the neonatal intensive care unit: Survey on current status [J].
Ashbaugh J.B. ;
Leick-Rude M.K. ;
Kilbride H.W. .
Journal of Perinatology, 1999, 19 (1) :48-52
[6]   Evaluation of noise in the neonatal intensive care unit [J].
Benini, F ;
Magnavita, V ;
Lago, P ;
Arslan, E ;
Pisan, P .
AMERICAN JOURNAL OF PERINATOLOGY, 1996, 13 (01) :37-41
[7]  
Berens R J, 1997, J Perinatol, V17, P351
[8]   NOISE MEASUREMENTS DURING HIGH-FREQUENCY OSCILLATORY AND CONVENTIONAL MECHANICAL VENTILATION [J].
BERENS, RJ ;
WEIGLE, CGM .
CHEST, 1995, 108 (04) :1026-1029
[9]  
Bowden VR, 2000, ONLINE J CLIN INNOVA, V3, P1
[10]   Noise and the premature infant: Physiological effects and practice implications [J].
Bremmer, P ;
Byers, JF ;
Kiehl, E .
JOGNN-JOURNAL OF OBSTETRIC GYNECOLOGIC AND NEONATAL NURSING, 2003, 32 (04) :447-454