RESPIRATOR CARTRIDGE TEST SYSTEM AND TEST-RESULTS FOR BENZENE AND ACRYLONITRILE

被引:1
|
作者
BEAUMONT, GP [1 ]
GARRIDO, CH [1 ]
机构
[1] DOW CHEM CO,MIDLAND,MI 48640
来源
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL | 1979年 / 40卷 / 10期
关键词
D O I
10.1080/15298667991430442
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
NIOSH approves organic vapor respirator cartridges based upon testing against 1000 parts per million carbon tetrachloride vapors. Data for other organic vapors are necessary for proper use of organic vapor cartridge respirators against those vapors. This paper describes a system designed to test respirator cartridges and canisters and results of cartridge tests against benzene and acrylonitrile at a variety of concentrations. Copyright 1979, American Industrial Hygiene Association