A STATIONARY HEMISPHERICAL SPECT IMAGER FOR 3-DIMENSIONAL BRAIN IMAGING

被引:0
|
作者
ROWE, RK
AARSVOLD, JN
BARRETT, HH
CHEN, JC
KLEIN, WP
MOORE, BA
PANG, IW
PATTON, DD
WHITE, TA
机构
[1] ARIZONA HLTH SCI CTR,DEPT RADIOL,TUCSON,AZ 85724
[2] UNIV ARIZONA,CTR OPT SCI,TUCSON,AZ 85721
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A completely stationary, hemispherical-coded aperture SPECT imaging system was designed to produce three-dimensional images of the brain. The system consisted of a hemispherical multiple-pinhole coded aperture and 20 small (100 x 100 mm crystal area) digital gamma cameras. Reconstructions and measured performance specifications from two laboratory versions of the imager are presented. The reconstructed field of view of these systems was an ellipsoidal region with semi-diameters of 100 x 100 x 50 mm. The reconstructed spatial resolution for a point source in air at the center of this field was found to be 4.8 mm FWHM and the corresponding system sensitivity was 36 cps/muCi. An analysis using an ideal-observer model indicated that the multiplexed projection data suffered a 21% degradation relative to similar, but nonmultiplexed SPECT data. Therefore, by this measure, the effective sensitivity of the brain imager was 79% of the measured value.
引用
收藏
页码:474 / 480
页数:7
相关论文
共 50 条
  • [41] FREQUENCY-DOMAIN IMPLEMENTATION OF THE 3-DIMENSIONAL GEOMETRIC POINT RESPONSE CORRECTION IN SPECT IMAGING
    ZENG, GL
    GULLBERG, GT
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (05) : 1444 - 1453
  • [42] 3-DIMENSIONAL DISPLAY OF SPECT IMAGES - ADVANTAGES AND PROBLEMS
    KEYES, JW
    JOURNAL OF NUCLEAR MEDICINE, 1990, 31 (08) : 1428 - 1430
  • [43] 3-DIMENSIONAL ATTENUATION COEFFICIENTS DISTRIBUTION FOR SPECT OF THE CHEST
    GUZZARDI, R
    LICITRA, G
    JOURNAL OF NUCLEAR MEDICINE, 1989, 30 (01) : 128 - 129
  • [44] VOLUME RENDERING IN 3-DIMENSIONAL DISPLAY OF SPECT IMAGES
    WALLIS, JW
    MILLER, TR
    JOURNAL OF NUCLEAR MEDICINE, 1990, 31 (08) : 1421 - 1428
  • [45] 3-DIMENSIONAL DISPLAY OF SPECT MYOCARDIAL PERFUSION SCANS
    HOULE, S
    YIP, TCK
    HOLLOWAY, R
    FELL, D
    LIU, P
    CLINICAL AND INVESTIGATIVE MEDICINE-MEDECINE CLINIQUE ET EXPERIMENTALE, 1988, 11 (03): : B9 - B9
  • [46] 3-DIMENSIONAL SCANNING OF THE BRAIN - SINGLE-PHOTON EMISSION COMPUTERIZED-TOMOGRAPHY (SPECT)
    DEISENHAMMER, E
    HOLL, K
    WIENER KLINISCHE WOCHENSCHRIFT, 1988, 100 (12) : 392 - 404
  • [47] High resolution SPECT imager for three-dimensional imaging of small animals.
    Kastis, GK
    Barber, HB
    Barrett, HH
    Gifford, HC
    Pang, IW
    Patton, DD
    Sain, JD
    Stevenson, G
    Wilson, DW
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 9P - 9P
  • [48] A FAST RECONSTRUCTION METHOD FOR 2-DIMENSIONAL AND 3-DIMENSIONAL SPECT
    HAMILL, JJ
    HAWMAN, EG
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P192 - P192
  • [49] COMBINED 3-DIMENSIONAL INTRAVASCULAR ULTRASOUND IMAGING AND 3-DIMENSIONAL FLOW PRESENTATION
    BURRELL, CJ
    KITNEY, RI
    GIDDENS, DP
    STRAUGHAN, K
    MCDONALD, AH
    ROTHMAN, MT
    BRITISH HEART JOURNAL, 1990, 64 (01): : 99 - 99
  • [50] Optimization of 3-dimensional imaging of the breast region with 3-dimensional laser scanners
    Kovacs, L
    Yassouridis, A
    Zimmermann, A
    Brockmann, G
    Wöhnl, A
    Blaschke, M
    Eder, M
    Schwenzer-Zimmerer, K
    Rosenberg, R
    Papadopulos, NA
    Biemer, E
    ANNALS OF PLASTIC SURGERY, 2006, 56 (03) : 229 - 236