A NEW METHOD FOR CONTINUOUS CHRONIC MEASUREMENT AND RECORDING OF BLOOD-PRESSURE, HEART-RATE AND ACTIVITY IN THE RAT VIA RADIOTELEMETRY

被引:235
作者
BROCKWAY, BP [1 ]
MILLS, PA [1 ]
AZAR, SH [1 ]
机构
[1] UNIV MINNESOTA,DEPT MED,MINNEAPOLIS,MN 55455
关键词
BLOOD PRESSURE; TELEMETRY; HEART RATE; ACTIVITY; CHRONIC MONITORING;
D O I
10.3109/10641969109042094
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Accurate continuous chronic measurements of blood pressure from conscious laboratory rats are critical to many experimental protocols but have been difficult or impossible to acquire. A system consisting of an implantable radio-telemetry device, receiver, and computer-based data acquisition system that allows such measurements to be easily obtained has been developed. This system is capable of monitoring and recording arterial pressure (waveform, systolic, diastolic, and mean), heart rate, and activity from rats weighing > 175 gm for periods in excess of 6 months. Chronic patency has been achieved through a patented design which includes an antithrombogenic film and a gel membrane located at the catheter tip. Validation of telemetered measurements via carotid catheter has demonstrated the accuracy to be better than +/- 5 mmHg in 85% (N = 20) tested at 3 weeks post implantation, 86% (N = 15) tested at 8 weeks, and 78% (N = 9) at 12 weeks. Incidence of loss of patency was 2.3% (N = 44). This system has a demonstrated ability to obtain accurate continuous chronic measurements of arterial pressure free of the stressors associated with conventional systems.
引用
收藏
页码:885 / 895
页数:11
相关论文
共 15 条
[1]  
ADAMS MR, 1988, LABORATORY ANIMAL SC, V38
[2]  
AZAR S, UNPUB CONTINUOUS BLO
[3]   REGIONAL VASCULAR INFLUENCES ON TAIL-CUFF MEASUREMENTS OF DRUG-INDUCED CHANGES IN SYSTOLIC PRESSURE [J].
BUNAG, RD ;
MUETING, N ;
RILEY, E .
JOURNAL OF APPLIED PHYSIOLOGY, 1975, 39 (05) :724-727
[4]   LACK OF CORRELATION BETWEEN DIRECT AND INDIRECT MEASUREMENTS OF ARTERIAL PRESSURE IN UNANAESTHETIZED RATS [J].
BUNAG, RD ;
MCCUBBIN, JW ;
PAGE, IH .
CARDIOVASCULAR RESEARCH, 1971, 5 (01) :24-&
[5]  
BUNAG RD, 1983, CLINE XPER HYPER T A, V5, P1959
[6]  
FUKUDA S, 1986, J CARDIOVASC PHARM, V8, P765
[7]  
KVETNANSKY R, 1977, PHARMACOLOGIST, V19, P241
[8]   NONINVASIVE MEASUREMENT OF SYSTEMIC ARTERIAL BLOOD-PRESSURE IN THE CONSCIOUS BEAGLE DOG [J].
PETTERSEN, JC ;
LINARTZ, RR ;
HAMLIN, RL ;
STOLL, RE .
FUNDAMENTAL AND APPLIED TOXICOLOGY, 1988, 10 (01) :89-97
[9]  
SYLVESTRI M, UNPUB PHARM METHODS
[10]   NORMAL CARDIAC-OUTPUT IN CONSCIOUS YOUNG SPONTANEOUSLY HYPERTENSIVE RAT - EVIDENCE FOR HIGHER OXYGEN UTILIZATION [J].
TADEPALLI, AS ;
WALSH, GM ;
TOBIA, AJ .
LIFE SCIENCES, 1974, 15 (06) :1103-1114