FACTORS INFLUENCING THE PERFORMANCE OF PEPTIDE-MAPPING BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

被引:31
作者
DONG, MW [1 ]
TRAN, AD [1 ]
机构
[1] ORTHO PHARMACEUT CORP,RARITAN,NJ 08869
来源
JOURNAL OF CHROMATOGRAPHY | 1990年 / 499卷
关键词
D O I
10.1016/S0021-9673(00)96968-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Factors controlling the performance of peptide mapping on reversed-phase columns were systematically evaluated. Performance criteria included resolution (peak capacity and selectivity), system reproducibility, sensitivity and analysis speed. Column configuration, characteristics of packing materials, mobile phase composition, operating variables and instrumental designs were found to influence the performance of peptide mapping. Considerations for peptide identification techniques are discussed. © 1990.
引用
收藏
页码:125 / 139
页数:15
相关论文
共 45 条
[1]  
ANTIA FD, 1988, J CHROMATOGR, V435, P1
[2]   COMPARISON OF REVERSED-PHASE COLUMNS FOR THE SEPARATION OF TRYPTIC PEPTIDES BY GRADIENT ELUTION - CORRELATION OF EXPERIMENTAL RESULTS AND MODEL PREDICTION [J].
BANES, AJ ;
LINK, GW ;
SNYDER, LR .
JOURNAL OF CHROMATOGRAPHY, 1985, 326 (JUN) :419-431
[3]  
BORMAN S, 1987, ANAL CHEM, V59, P969
[4]  
BROWN JL, 1976, J BIOL CHEM, V251, P1009
[5]   SEPARATION OF PROTEINS BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .1. OPTIMIZING THE COLUMN [J].
BURTON, WG ;
NUGENT, KD ;
SLATTERY, TK ;
SUMMERS, BR ;
SNYDER, LR .
JOURNAL OF CHROMATOGRAPHY, 1988, 443 :363-379
[6]   STUDY OF THE PRIMARY STRUCTURE OF RECOMBINANT TISSUE PLASMINOGEN-ACTIVATOR BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC TRYPTIC MAPPING [J].
CHLOUPEK, RC ;
HARRIS, RJ ;
LEONARD, CK ;
KECK, RG ;
KEYT, BA ;
SPELLMAN, MW ;
JONES, AJS ;
HANCOCK, WS .
JOURNAL OF CHROMATOGRAPHY, 1989, 463 (02) :375-396
[7]   EFFECTS OF CHAIN-LENGTH AND CARBON LOAD ON THE PERFORMANCE OF ALKYL-BONDED SILICAS FOR PROTEIN SEPARATIONS [J].
COOKE, NHC ;
ARCHER, BG ;
OHARE, MJ ;
NICE, EC ;
CAPP, M .
JOURNAL OF CHROMATOGRAPHY, 1983, 255 (JAN) :115-123
[8]  
CRESTFIELD AM, 1963, J BIOL CHEM, V238, P622
[9]   SYNTHESIS AND CHARACTERIZATION OF 2-MU-M WIDE-PORE SILICA MICROSPHERES AS COLUMN PACKINGS FOR THE REVERSED-PHASE LIQUID-CHROMATOGRAPHY OF PEPTIDES AND PROTEINS [J].
DANIELSON, ND ;
KIRKLAND, JJ .
ANALYTICAL CHEMISTRY, 1987, 59 (20) :2501-2506
[10]   ISOLATION OF TRYPTIC PEPTIDES OF MYELIN BASIC-PROTEIN BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
DEIBLER, GE ;
BOYD, LF ;
MARTENSON, RE ;
KIES, MW .
JOURNAL OF CHROMATOGRAPHY, 1985, 326 (JUN) :433-442