COMPARISON OF STRESS ECHOCARDIOGRAPHY AND STRESS MYOCARDIAL PERFUSION SCINTIGRAPHY FOR DIAGNOSING CORONARY-ARTERY DISEASE AND ASSESSING ITS SEVERITY

被引:72
作者
OKEEFE, JH [1 ]
BARNHART, CS [1 ]
BATEMAN, TM [1 ]
机构
[1] UNIV MISSOURI, ST LUKES HOSP, MID AMER HEART INST, KANSAS CITY, MO USA
关键词
D O I
10.1016/S0002-9149(99)80399-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The cumulative published literature dealing with the most frequently utilized noninvasive cardiac stress imaging modalities (radionuclide myocardial perfusion scintigraphy and echocardiography) was reviewed to gain insight on their comparative diagnostic accuracies. To be included, studies had to be performed in conjunction with exercise or a commonly used intravenous pharmacologic stress agent (dipyridamole, adenosine or dobutamine) and had to report temporally related coronary angiography findings. A total of >75 studies were included, involving >7,000 patients. Exercise single-photon emitted computed tomographic (SPECT) scintigraphy was more sensitive than exercise echocardiography for detecting coronary artery disease (CAD), localizing it to the proper coronary artery distribution and correctly identifying the presence of multivessel CAD. Adenosine, dipyridamole, and dobutamine provided similar diagnostic accuracy when performed in conjunction with SPECT scintigraphy, and all were more accurate than dobutamine echocardiography. Clinical specificity was similarly high with adenosine SPECT, dipyridamole echocardiography, and exercise echocardiography, and lower with exercise SPECT. Normalcy rate was high for exercise SPECT and similar to clinical specificity for echocardiography.
引用
收藏
页码:D25 / D34
页数:10
相关论文
共 92 条
[31]   DIGITAL SUPINE BICYCLE STRESS ECHOCARDIOGRAPHY - A NEW TECHNIQUE FOR EVALUATING CORONARY-ARTERY DISEASE [J].
HECHT, HS ;
DEBORD, L ;
SHAW, R ;
DUNLAP, R ;
RYAN, C ;
STERTZER, SH ;
MYLER, RK .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (04) :950-956
[32]   COMPARATIVE-EVALUATION OF BICYCLE AND DOBUTAMINE STRESS ECHOCARDIOGRAPHY WITH PERFUSION SCINTIGRAPHY AND BICYCLE ELECTROCARDIOGRAM FOR IDENTIFICATION OF CORONARY-ARTERY DISEASE [J].
HOFFMANN, R ;
LETHEN, H ;
KLEINHANS, E ;
WEISS, M ;
FLACHSKAMPF, FA ;
HANRATH, P .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (07) :555-559
[33]   EFFECT OF EXERCISE LEVEL ON THE ABILITY OF TL-201 TOMOGRAPHIC IMAGING IN DETECTING CORONARY-ARTERY DISEASE - ANALYSIS OF 461 PATIENTS [J].
ISKANDRIAN, AS ;
HEO, JY ;
KONG, B ;
LYONS, E .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (06) :1477-1486
[34]   IDENTIFICATION OF HIGH-RISK PATIENTS WITH LEFT MAIN AND 3-VESSEL CORONARY-ARTERY DISEASE BY ADENOSINE SINGLE PHOTON-EMISSION COMPUTED TOMOGRAPHIC THALLIUM IMAGING [J].
ISKANDRIAN, AS ;
HEO, J ;
LEMLEK, J ;
OGILBY, JD ;
UNTEREKER, WJ ;
ISKANDRIAN, B ;
CAVE, V .
AMERICAN HEART JOURNAL, 1993, 125 (04) :1130-1135
[35]   USEFULNESS OF TWO-DIMENSIONAL EXERCISE ECHOCARDIOGRAPHY SHORTLY AFTER MYOCARDIAL-INFARCTION [J].
JAARSMA, W ;
VISSER, CA ;
KUPPER, AJF ;
RES, JCJ ;
VANEENIGE, MJ ;
ROOS, JP .
AMERICAN JOURNAL OF CARDIOLOGY, 1986, 57 (01) :86-90
[36]   QUANTITATIVE ROTATIONAL TOMOGRAPHY WITH TL-201 AND TC-99M 2-METHOXY-ISOBUTYL-ISONITRILE - A DIRECT COMPARISON IN NORMAL INDIVIDUALS AND PATIENTS WITH CORONARY-ARTERY DISEASE [J].
KAHN, JK ;
MCGHIE, I ;
AKERS, MS ;
SILLS, MN ;
FABER, TL ;
KULKARNI, PV ;
WILLERSON, JT ;
CORBETT, JR .
CIRCULATION, 1989, 79 (06) :1282-1293
[37]   DETERMINATION OF THE QUANTITATIVE THALLIUM IMAGING VARIABLES THAT OPTIMIZE DETECTION OF CORONARY-ARTERY DISEASE [J].
KAUL, S ;
BOUCHER, CA ;
NEWELL, JB ;
CHESLER, DA ;
GREENBERG, JM ;
OKADA, RD ;
STRAUSS, HW ;
DINSMORE, RE ;
POHOST, GM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (03) :527-537
[38]  
KAUL S, 1993, NUCLEAR CARDIOLOGY S, P181
[39]   COMPARISON OF TECHNETIUM-99M METHOXY ISOBUTYL ISONITRILE AND TL-201 FOR EVALUATION OF CORONARY-ARTERY DISEASE BY PLANAR AND TOMOGRAPHIC METHODS [J].
KIAT, H ;
MADDAHI, J ;
ROY, LT ;
VANTRAIN, K ;
FRIEDMAN, J ;
RESSER, K ;
BERMAN, DS .
AMERICAN HEART JOURNAL, 1989, 117 (01) :1-11
[40]   COMPARISON OF ACCURACY FOR DETECTING CORONARY-ARTERY DISEASE AND SIDE-EFFECT PROFILE OF DIPYRIDAMOLE TL-201 MYOCARDIAL PERFUSION IMAGING IN WOMEN VERSUS MEN [J].
KONG, BA ;
SHAW, L ;
MILLER, DD ;
CHAITMAN, BR .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (02) :168-173