The Effects of Single-Level Instrumented Lumbar Laminectomy on Adjacent Spinal Biomechanics

被引:11
|
作者
Bisschop, Arno [1 ]
Holewijn, Roderick M. [1 ]
Kingma, Idsart [2 ]
Stadhouder, Agnita [1 ]
Vergroesen, Pieter-Paul A. [1 ]
van der Veen, Albert J. [3 ]
van Dieen, Jaap H. [2 ,4 ]
van Royen, Barend J. [1 ]
机构
[1] Vrije Univ Amsterdam, Med Ctr, Res Inst MOVE, Dept Orthopaed Surg, De Boelelaan 1117, NL-1081 HV Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Res Inst MOVE, Fac Human Movement Sci, Amsterdam, Netherlands
[3] Vrije Univ Amsterdam, Med Ctr, Dept Phys & Med Technol, NL-1081 HV Amsterdam, Netherlands
[4] King Abdulaziz Univ, Dept Biomed Engn, Jeddah 21413, Saudi Arabia
关键词
human lumbar spine; single-level laminectomy; instrumentation; biomechanics; adjacent segment disease (ASD);
D O I
10.1055/s-0034-1395783
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design Biomechanical study. Objective Posterior instrumentation is used to stabilize the spine after a lumbar laminectomy. However, the effects on the adjacent segmental stability are unknown. Therefore, we studied the range of motion (ROM) and stiffness of treated lumbar spinal segments and cranial segments after a laminectomy and after posterior instrumentation in flexion and extension (FE), lateral bending (LB), and axial rotation (AR). These outcomes might help to better understand adjacent segment disease (ASD), which is reported cranial to the level on which posterior instrumentation is applied. Methods We obtained 12 cadaveric human lumbar spines. Spines were axially loaded with 250 N for 1 hour. Thereafter, 10 consecutive load cycles (4 Nm) were applied in FE, LB, and AR. Subsequently, a laminectomy was performed either at L2 or at L4. Thereafter, load-deformation tests were repeated, after similar preloading. Finally, posterior instrumentation was added to the level treated with a laminectomy before testing was repeated. The ROM and stiffness of the treated, the cranial adjacent, and the control segments were calculated from the load-displacement data. Repeated-measures analyses of variance used the spinal level as the between-subject factor and a laminectomy or instrumentation as the within-subject factors. Results After the laminectomy, the ROM increased (+19.4%) and the stiffness decreased (-18.0%) in AR. The ROM in AR of the adjacent segments also increased (+11.0%). The ROM of treated segments after instrumentation decreased in FE (-74.3%), LB (-71.6%), and AR (-59.8%). In the adjacent segments after instrumentation, only the ROM in LB was changed (-12.9%). Conclusions The present findings do not substantiate a biomechanical pathway toward or explanation for ASD.
引用
收藏
页码:39 / 47
页数:9
相关论文
共 50 条
  • [1] Comparison of Single-Level and Multilevel Decompressive Laminectomy for Multilevel Lumbar Spinal Stenosis
    Adilay, Utku
    Guclu, Bulent
    WORLD NEUROSURGERY, 2018, 111 : E228 - E233
  • [2] Dynamic stabilization adjacent to single-level fusion: Part I. Biomechanical effects on lumbar spinal motion
    Patrick Strube
    Stephan Tohtz
    Eike Hoff
    Christian Gross
    Carsten Perka
    Michael Putzier
    European Spine Journal, 2010, 19 : 2171 - 2180
  • [3] Dynamic stabilization adjacent to single-level fusion: Part I. Biomechanical effects on lumbar spinal motion
    Strube, Patrick
    Tohtz, Stephan
    Hoff, Eike
    Gross, Christian
    Perka, Carsten
    Putzier, Michael
    EUROPEAN SPINE JOURNAL, 2010, 19 (12) : 2171 - 2180
  • [4] Large-Scale Comparative Study Between Microendoscopic Laminectomy and FullEndoscopic Laminectomy for the Treatment of Single-Level Lumbar Spinal Canal Stenosis
    Takebayashi, Kento
    Fujita, Muneyoshi
    Inui, Takahiro
    Oshima, Yasushi
    Iwai, Hiroki
    Inanami, Hirohiko
    Koga, Hisashi
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (01)
  • [5] Efficacy of closed wound suction drainage after single-level lumbar laminectomy
    Payne, DH
    Fischgrund, JS
    Herkowitz, HN
    Barry, RL
    Kurz, LT
    Montgomery, DM
    JOURNAL OF SPINAL DISORDERS, 1996, 9 (05): : 401 - 403
  • [6] The biomechanical effect of single-level laminectomy and posterior instrumentation on spinal stability in degenerative lumbar scoliosis: a human cadaveric study
    Rustenburg, Christine M. E.
    Faraj, Sayf S. A.
    Holewijn, Roderick M.
    Kingma, Idsart
    van Royen, Barend J.
    Stadhouder, Agnita
    Emanuel, Kaj S.
    NEUROSURGICAL FOCUS, 2019, 46 (05)
  • [7] Unilateral decompressive laminectomy plus fusion using unilateral biportal endoscopic technique for single-level lumbar spinal stenosis
    Xu, Dingli
    Shu, Wubin
    Lian, Leidong
    Jiang, Weiyu
    Hu, Xudong
    Gan, Kaifeng
    Ma, Weihu
    ASIAN JOURNAL OF SURGERY, 2024, 47 (08) : 3457 - 3463
  • [8] Biomechanics of adjacent segment after three-level lumbar fusion, hybrid single-level semi-rigid fixation with two-level lumbar fusion
    Zhang, Mingzheng
    Ren, Weiyan
    Mo, Zhongjun
    Li, Jian
    Pu, Fang
    Fan, Yubo
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2022, 25 (04) : 455 - 463
  • [9] Effect of Facet Joint Resection on Postoperative Radiographic and Clinical Outcomes After Microendoscopic Laminectomy for Single-Level Lumbar Spinal Stenosis
    Doi, Toru
    Hirai, Shima
    Horii, Chiaki
    Sasaki, Katsuyuki
    Yamato, Yukimasa
    Nakajima, Koji
    Okazaki, Ken
    Inanami, Hirohiko
    Iwai, Hiroki
    Oshima, Yasushi
    WORLD NEUROSURGERY, 2024, 192 : E565 - E571
  • [10] Subtle segmental angle changes of single-level lumbar fusions and adjacent-level biomechanics: cadaveric study of optically measured disc strain
    Pereira, Bernardo de Andrada
    Wangsawatwong, Piyanat
    Lehrman, Jennifer N.
    Sawa, Anna G. U.
    Farber, S. Harrison
    Godzik, Jakub
    O'Neill, Luke K.
    Uribe, Juan S.
    Kelly, Brian P.
    Turner, Jay D.
    JOURNAL OF NEUROSURGERY-SPINE, 2022, 37 (04) : 525 - 534