ENANTIOSELECTIVE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF (SR)-MEFLOQUINE AND (RS)-MEFLOQUINE IN PLASMA USING N-BENZYLOXYCARBONYL-GLYCYL-L-PROLINE AS CHIRAL COUNTER ION

被引:14
作者
BERGQVIST, Y
ALKABBANI, J
PETTERSSON, C
HUYNH, NH
机构
[1] HUDDINGE UNIV HOSP,KAROLINSKA INST,DEPT CLIN PHARMACOL,TROP PHARMACOL UNIT,S-14186 HUDDINGE,SWEDEN
[2] UNIV UPPSALA,CTR BIOMED,DEPT ANALYT PHARMACEUT CHEM,S-75123 UPPSALA,SWEDEN
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1993年 / 620卷 / 02期
关键词
D O I
10.1016/0378-4347(93)80007-Q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A stereoselective HPLC method is described for the determination of (SR)-and (RS)-mefloquine in plasma. The direct chiral separation is carried out on a Hypercarb-S column (porous graphitised carbon) with N-benzyloxycarbonyl-glycyl-L-proline (L-ZGP) as a chiral counter-ion in a reversed-phase system. The sample work-up included protein precipitation by addition of zinc sulphate and acetonitrile followed by liquid-liquid extraction with methyl-tert.-butyl ether. After evaporation of the organic phase, the residue is dissolved in the mobile phase and injected onto the column. Analyses of the enantiomers in plasma after a single oral dose of mefloquine indicates that the pharmacokinetics of the two enantiomers are different. The method is validated by determining the absolute recovery, linearity, accuracy, precision and inter- and intra-assay variation.
引用
收藏
页码:217 / 224
页数:8
相关论文
共 21 条
[1]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS OF MEFLOQUINE AND ITS MAIN METABOLITE BY DIRECT PLASMA INJECTION WITH PRECOLUMN ENRICHMENT AND COLUMN SWITCHING TECHNIQUES [J].
ARNOLD, PJ ;
STETTEN, OV .
JOURNAL OF CHROMATOGRAPHY, 1986, 353 :193-200
[2]   INVITRO ACTIVITY OF THE ENANTIOMERS OF MEFLOQUINE, HALOFANTRINE AND ENPIROLINE AGAINST PLASMODIUM-FALCIPARUM [J].
BASCO, LK ;
GILLOTIN, C ;
GIMENEZ, F ;
FARINOTTI, R ;
LEBRAS, J .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1992, 33 (05) :517-520
[3]   DETERMINATION OF MEFLOQUINE BY ELECTRON-CAPTURE GAS-CHROMATOGRAPHY AFTER PHOSGENE DERIVATIZATION IN BIOLOGICAL SAMPLES AND IN CAPILLARY BLOOD COLLECTED ON FILTER-PAPER [J].
BERGQVIST, Y ;
CHURCHILL, FC ;
MOUNT, DL .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 428 (02) :281-290
[4]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR THE SIMULTANEOUS MONITORING OF MEFLOQUINE AND ITS ACID METABOLITE IN BIOLOGICAL SAMPLES USING PROTEIN PRECIPITATION AND ION-PAIR EXTRACTION [J].
BERGQVIST, Y ;
HELLGREN, U ;
CHURCHILL, FC .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 432 :253-263
[5]  
CAILLON E, 1992, AM J PSYCHIAT, V149, P712
[6]   OPTICAL ISOMERS OF ARYL-2-PIPERIDYLMETHANOL ANTIMALARIAL AGENTS - PREPARATION, OPTICAL PURITY, AND ABSOLUTE STEREOCHEMISTRY [J].
CARROLL, FI ;
BLACKWELL, JT .
JOURNAL OF MEDICINAL CHEMISTRY, 1974, 17 (02) :210-219
[7]   GAS-CHROMATOGRAPHIC DETERMINATION OF MEFLOQUINE IN HUMAN AND DOG PLASMA USING ELECTRON-CAPTURE DETECTION [J].
DADGAR, D ;
CLIMAX, J ;
LAMBE, R ;
DARRAGH, A .
JOURNAL OF CHROMATOGRAPHY, 1985, 337 (01) :47-54
[8]  
ERICSSON O, 1992, 13 INT C TROP MED MA, P278
[9]   PEAK DISTORTION EFFECTS OF SURAMIN DUE TO LARGE SYSTEM PEAKS IN BIOANALYSIS USING ION-PAIR ADSORPTION CHROMATOGRAPHY [J].
FORNSTEDT, T .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 612 (01) :137-144
[10]  
FORNSTEDT T, 1992, THESIS UPPSALA U SWE