A PROPOSAL FOR SCIENTIFIC VALIDATION OF INSTRUMENTS FOR INDIRECT BLOOD-PRESSURE MEASUREMENT AT REST, DURING EXERCISE, AND IN CRITICAL CARE

被引:5
作者
IYRIBOZ, Y
HEARON, CM
机构
[1] Department of Kinesiology, Louisiana State University, Baton Rouge, LA
来源
JOURNAL OF CLINICAL MONITORING | 1994年 / 10卷 / 03期
关键词
MONITORING; BLOOD PRESSURE; EQUIPMENT; MONITORS;
D O I
10.1007/BF02908856
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective. The purpose of this study was to provide a critical review and comprehensive outline of published guidelines for the validation of monitors for indirect blood pressure (BP) measurement in light of recent research and practical clinical experience. Methods. Studies testing the reliability and validity of BP monitors and available guidelines for validation have been reviewed and compared. Results. The validation studies of instruments for indirect BP measurement have used a wide variety of sample pools, BP ranges, protocols, reference instruments, and statistical procedures, thereby making it impossible to reach a consensus. Few existing recommendations for validation have been found to be incomplete with respect to BP in various physiological states, sequence of procedures, sample, and statistical analysis. Conclusions. A new sequence of procedures for validation, including assessment of instruments during exercise and in critical care, is introduced. Previously suggested sample sizes for study subjects, age, and BP groups, as well as margins of error, are statistically challenged. Insufficiency of linear relationship and aggregate agreement alone in determining the interchangeability between a reference and test instrument is demonstrated by quantification of agreement.
引用
收藏
页码:163 / 177
页数:15
相关论文
共 67 条
[1]  
ANDERSON RB, 1981, STATPOWER PC PROGRAM
[2]  
[Anonymous], 1987, PEDIATRICS, V79, P1
[3]   THE ACCURACY AND PRECISION OF THE ACCUTRACKER AMBULATORY BLOOD-PRESSURE MONITOR [J].
APPEL, LJ ;
WHELTON, PK ;
SEIDLER, AJ ;
PATEL, AR ;
KLAG, MJ .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 1990, 132 (02) :343-354
[4]   EVALUATION OF AN AUTOMATED BLOOD-PRESSURE MEASURING DEVICE INTENDED FOR GENERAL PUBLIC USE [J].
BERKSON, DM ;
WHIPPLE, IT ;
SHIREMAN, L ;
BROWN, MC ;
RAYNOR, W ;
SHEKELLE, RB .
AMERICAN JOURNAL OF PUBLIC HEALTH, 1979, 69 (05) :473-479
[5]  
BIOSCA MD, 1990, J CARDIOVASC PHAR S8, V16, P26
[6]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]  
Bradley J G, 1989, J Am Board Fam Pract, V2, P247
[8]   BLOOD-PRESSURE BY AGE IN CHILDHOOD AND ADOLESCENCE - A REVIEW OF 129 SURVEYS WORLDWIDE [J].
BROTONS, C ;
SINGH, P ;
NISHIO, T ;
LABARTHE, DR .
INTERNATIONAL JOURNAL OF EPIDEMIOLOGY, 1989, 18 (04) :824-829
[9]  
BRUNER J, 1978, HDB BLOOD PRESSURE M, P11
[10]  
BRUNER JMR, 1981, MED INSTRUM, V14, P182