Radiation therapy for stereotactic body radiation therapy in spine tumors: linac or robotic?

被引:3
|
作者
De Ornelas-Couto, Mariluz [1 ]
Bossart, Elizabeth [1 ]
Ly, Bevan [1 ]
Monterroso, Maria Irene [1 ]
Mihaylov, Ivaylo [1 ]
机构
[1] Univ Miami, Dept Radiat Oncol, Miami, FL 33156 USA
来源
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS | 2016年 / 2卷 / 01期
关键词
SBRT; spine; CyberKnife; VMAT; IMRT;
D O I
10.1088/2057-1976/2/1/015012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Stereotactic body radiotherapy (SBRT) is used for spine treatments as it precisely delivers high radiation dose to tumors in close proximity to organs-at-risk (OARs). The goal of this work is to evaluate dosimetric properties of SBRT for spinal treatments with linear accelerators and CyberKnife (CK). Materials and methods: Plans of 27 patients, treated with CK for spine tumors, were also retrospectively optimized for linac-based (LB) intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). One nine-field IMRT plan and five VMAT plans were generated for each patient. The LB target volumes were uniformly expanded by 0.1 cm to accommodate for the uncertainty in patient positioning. All plans were optimized to cover 90% of the target volumes with a prescription dose of 27 Gy in three fractions. If dose constraints to OARs were not met, the prescription dose was decreased to 24 Gy. Target dose conformity and falloff were evaluated with Paddick's conformity (CI) and gradient (GI) indices. Results: PTV expansion resulted in a 31.5% volume increase in the LB plans. The three full-arcs VMAT(VMAT_3full) plans resulted in the best average CI(0.820) compared to CK(0.758) with worst average from one half-arcs VMAT (VMAT_1half) plans (0.747). Dose falloff was also superior with the VMAT_3full plans with an average GI value of 3.596, in comparison to CK(3.786) and IMRT(4.447). In 6 cases CKplans were unable to meet OAR constraints and the prescription dose was decreased to 24 Gy, compared to only 2 for VMAT_3full. Conclusion: Regardless of the larger target volumes, LB plans were comparable to CK plans. Conformity of target doses of the VMAT_3full plans were better than CK in all cases and dose fall-off was better 23 of 27 plans. Dose to OARs were lower for CK, but constraints met for all plans. The use of VMAT would reduce the treatment time.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Robotic stereotactic body radiation therapy for liver-limited malignant tumors
    Fraczek, Mariusz
    Sobocki, Jacek
    Pedziwiatr, Katarzyna
    Skrocki, Edward
    Piotrkowicz, Norbert
    Tyc-Szczepaniak, Dobromira
    Korab-Chrzanowska, Elzbieta
    Hevelke, Piotr
    Krasnodebski, Maciej
    Koszewski, Waldemar
    VIDEOSURGERY AND OTHER MINIINVASIVE TECHNIQUES, 2014, 9 (04) : 511 - 516
  • [2] Stereotactic body radiation therapy for benign spine tumors: is dose de-escalation appropriate?
    Kalash, Ronny
    Glaser, Scott M.
    Flickinger, John C.
    Burton, Steven
    Heron, Dwight E.
    Gerszten, Peter C.
    Engh, Johnathan A.
    Amankulor, Nduka M.
    Vargo, John A.
    JOURNAL OF NEUROSURGERY-SPINE, 2018, 29 (02) : 220 - 225
  • [3] Optimization of normalized prescription isodose selection for stereotactic body radiation therapy: Conventional vs robotic linac
    Ding, Chuxiong
    Solberg, Timothy D.
    Hrycushko, Brian
    Xing, Lei
    Heinzerling, John
    Timmerman, Robert D.
    MEDICAL PHYSICS, 2013, 40 (05)
  • [4] Radiation myelopathy following stereotactic body radiation therapy for spine metastases
    Wee Loon Ong
    Shun Wong
    Hany Soliman
    Sten Myrehaug
    Chia-Lin Tseng
    Jay Detsky
    Zain Husain
    Pejman Maralani
    Lijun Ma
    Simon S. Lo
    Arjun Sahgal
    Journal of Neuro-Oncology, 2022, 159 : 23 - 31
  • [5] Radiation myelopathy following stereotactic body radiation therapy for spine metastases
    Ong, Wee Loon
    Wong, Shun
    Soliman, Hany
    Myrehaug, Sten
    Tseng, Chia-Lin
    Detsky, Jay
    Husain, Zain
    Maralani, Pejman
    Ma, Lijun
    Lo, Simon S.
    Sahgal, Arjun
    JOURNAL OF NEURO-ONCOLOGY, 2022, 159 (01) : 23 - 31
  • [6] Vertebral body fracture rates after stereotactic body radiation therapy compared with external-beam radiation therapy for metastatic spine tumors
    Vargas, Enrique
    Susko, Matthew S.
    Mummaneni, Praveen V.
    Braunstein, Steve E.
    Chou, Dean
    JOURNAL OF NEUROSURGERY-SPINE, 2020, 33 (06) : 870 - 876
  • [7] Stereotactic Body Radiation Therapy for Nonresectable Tumors of the Pancreas
    Goyal, Kush
    Einstein, Douglas
    Ibarra, Rafael A.
    Yao, Min
    Kunos, Charles
    Ellis, Rod
    Brindle, James
    Singh, Deepjot
    Hardacre, Jeffrey
    Zhang, Yuxia
    Fabians, Jeffrey
    Funkhouser, Gary
    Machtay, Mitchell
    Sanabria, Juan R.
    JOURNAL OF SURGICAL RESEARCH, 2012, 174 (02) : 319 - 325
  • [8] A comparison of stereotactic body radiation therapy for metastases to the sacral spine and treatment of the thoracolumbar spine
    Kowalchuk, Roman O.
    Waters, Michael R.
    Richardson, K. Martin
    Spencer, Kelly
    Larner, James M.
    Sheehan, Jason P.
    McAllister, William H.
    Kersh, Charles R.
    JOURNAL OF RADIOSURGERY AND SBRT, 2020, 7 (02): : 95 - 103
  • [9] Stereotactic body radiation therapy for spine bone oligometastatic disease
    Thureau, S.
    Roge, M.
    Marchesi, V
    Henni, A. Hadj
    Faivre, J. C.
    CANCER RADIOTHERAPIE, 2021, 25 (08): : 830 - 836
  • [10] The Evolving Role of Stereotactic Radiosurgery and Stereotactic Radiation Therapy for Patients with Spine Tumors
    Jack P. Rock
    Samuel Ryu
    Fang-Fang Yin
    Faye Schreiber
    Muwaffak Abdulhak
    Journal of Neuro-Oncology, 2004, 69 : 319 - 334