DETERMINATION OF ATROPINE AND OBIDOXIME IN AUTOMATIC INJECTION DEVICES USED AS ANTIDOTES AGAINST NERVE AGENT INTOXICATION

被引:23
作者
POHJOLA, J
HARPF, M
机构
[1] Military Pharmacy. Mannerheimintie 164
关键词
D O I
10.1016/0021-9673(94)00780-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A capillary gas-liquid chromatographic (GLC) and an ion-pair high performance liquid chromatographic (HPLC) method were developed for the assay of atropine sulphate and obidoxime chloride from a parenteral solution in commercial automatic injection devices. The injectors are aimed for the emergency treatment of poisoning by nerve agents. The two-step GLC method consists of extraction of atropine as a free base prior to GLC analysis using scopolamine as an internal standard. Obidoxime is determined directly in a diluted sample solution by reversed-phase HPLC using sodium 1-heptanesulphonate as a counter ion in the mobile phase. The relative standard deviation (R.S.D.) was 1.81% for the GLC procedure with injectors containing only atropine and 2.37% for the GLC of atropine in atropine-obidoxime injectors. The R.S.D. for the HPLC procedure of obidoxime in atropine-obidoxime injectors was 0.82%. The corresponding R.S.D.s for the sampling of atropine-obidoxime injectors were 0.36% and 0.27%. The coefficient of determination (r(2)) was 1.000 for both methods. The recoveries at the target concentration averaged 101.0% and 98.7% with a standard error of the mean of 0.30 for both methods. The retention times for atropine and obidoxime were 6.27 and 4.29 min, respectively.
引用
收藏
页码:350 / 354
页数:5
相关论文
共 33 条
[1]   DETERMINATION OF SOME PYRIDINIUM ALDOXIME COMPOUNDS BY MEANS OF ION-PAIR REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - APPLICATION IN BIOLOGICAL-MATERIAL [J].
BENSCHOP, HP ;
KONINGS, KAG ;
KOSSEN, SP ;
LIGTENSTEIN, DA .
JOURNAL OF CHROMATOGRAPHY, 1981, 225 (01) :107-114
[2]   GAS-CHROMATOGRAPHIC ASSAY OF ATROPINE IN FORMULATIONS CONTAINING ATROPINE SULFATE AND CHOLINESTERASE REACTIVATORS [J].
BRIGGS, CJ ;
SIMONS, KJ .
JOURNAL OF CHROMATOGRAPHY, 1983, 257 (01) :132-136
[3]  
BRIGGS CJ, 1980, 27TH P CAN C PHARM R, P12
[4]  
CHRISTENSON I, 1968, ACTA PHARM SUEC, V5, P23
[5]  
CIERI UR, 1985, J ASSOC OFF ANA CHEM, V68, P1042
[6]  
DUEZ P, 1985, J CHROMATOGR, V392, P415
[7]  
EIGENDORF HG, 1908, PHARMAZIE, V43, P287
[8]   LEACHING OF ZINC COMPOUND FROM RUBBER STOPPERS INTO THE CONTENTS OF AUTOMATIC ATROPINE INJECTORS [J].
ELLIN, RI ;
KAMINSKIS, A ;
ZVIRBLIS, P ;
SULTAN, WE ;
SHUTZ, MB ;
MATTHEWS, R .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1985, 74 (07) :788-790
[9]  
Gosselin R.E., 1976, Clinical Toxicology of Commercial Products: Acute Poisoning
[10]   THE ASSAY OF TROPANE DERIVATIVES IN FORMULATIONS BY 2ND DERIVATIVE ULTRAVIOLET SPECTROPHOTOMETRY [J].
HASSAN, SM ;
DAVIDSON, AG .
JOURNAL OF PHARMACY AND PHARMACOLOGY, 1984, 36 (01) :7-10