DIFFERENCES IN REPORTED BACKSCATTER FACTORS FOR LOW-ENERGY X-RAYS - A LITERATURE STUDY

被引:23
|
作者
CARLSSON, CA
机构
[1] Dept. of Radiation Phys., Linkoping Univ.
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1993年 / 38卷 / 04期
关键词
D O I
10.1088/0031-9155/38/4/004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
For low energy x-rays (HVL < 8 nun Al) large differences (up to 10%) in backscatter factors have been reported between new Monte Carlo calculations and old measurements. Minor differences (up to 3%) have been shown between recent measurements and these calculations. These differences have been said to be caused by errors mainly in the measurements. All investigations (old and new) have presented BSF as a function Of HVL. By regarding the x-ray spectra used by the different investigators the differences are explainable. Even the old BsF-values may be correct if, as presumable, they are obtained with higher voltage, larger voltage ripple and lower filtration than used by the recent investigators.
引用
收藏
页码:521 / 531
页数:11
相关论文
共 50 条
  • [1] LOW-ENERGY COSMIC X-RAYS
    SHUKLA, PG
    WILSON, BG
    ASTROPHYSICAL JOURNAL, 1971, 164 (02): : 265 - &
  • [2] LOW-ENERGY DIFFUSE X-RAYS
    BUNNER, AN
    COLEMAN, PL
    KRAUSHAAR, WL
    MCCAMMON, D
    ASTROPHYSICAL JOURNAL, 1971, 167 (01): : L3 - +
  • [3] ACCURATE DOSIMETRY OF LOW-ENERGY X-RAYS
    LYONS, PB
    BARAN, JA
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1971, 14 (02): : 908 - &
  • [4] DETECTION OF LOW-ENERGY COSMIC X-RAYS
    FRANCEY, RJ
    BAIRD, GA
    GREEN, DW
    WILSON, BG
    WOOLLAM, WH
    NUCLEAR INSTRUMENTS & METHODS, 1973, 107 (03): : 589 - 595
  • [5] ELECTRET DOSIMETER FOR LOW-ENERGY X-RAYS
    RICARD, M
    LISBONA, A
    MORUCCI, JP
    ROULLEAU, J
    NUCLEAR INSTRUMENTS & METHODS, 1980, 175 (01): : 129 - 130
  • [6] ATTENUATION OF LOW-ENERGY X-RAYS IN THE AIR
    DIETZSCH, W
    ISOTOPENPRAXIS, 1987, 23 (12): : 456 - 459
  • [7] Dosimetry of Low-Energy Characteristic X-Rays
    Tucker, M.
    Starin, R.
    McCray, M.
    Rakowski, J.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [8] Design and performance study of a proportional counter for low-energy X-rays
    Li, Meng Yu
    Zhao, Rui
    Xiong, Tao
    Wu, Jin Jie
    Fu, Lin
    Yu, Tao
    Zhu, Wei Feng
    Tang, Xian Qiang
    Lu, Ping Zhou
    Qu, Bing Bing
    RADIATION PHYSICS AND CHEMISTRY, 2023, 206
  • [9] Study of the response function of a HPGe detector for low-energy X-rays
    Lépy, MC
    Plagnard, J
    Ferreux, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 505 (1-2): : 290 - 293
  • [10] THE APPLICATION OF MICRODOSIMETRIC MEASUREMENTS TO THE STUDY OF THE DOSIMETRY OF LOW-ENERGY X-RAYS
    WAKER, AJ
    EIVAZI, MT
    RADIATION PROTECTION DOSIMETRY, 1989, 29 (1-2) : 75 - 79