PREDICTION OF MIGRATION BEHAVIOR OF OLIGONUCLEOTIDES IN CAPILLARY GEL-ELECTROPHORESIS

被引:45
作者
GUTTMAN, A
NELSON, RJ
COOKE, N
机构
[1] Beckman Instruments, Inc., Palo Alto
来源
JOURNAL OF CHROMATOGRAPHY | 1992年 / 593卷 / 1-2期
关键词
D O I
10.1016/0021-9673(92)80298-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The influence of the primary structure (base composition) on the electrophoretic migration properties of single-stranded oligodeoxyribonucleotides in capillary polyacrylamide gel electrophoresis was investigated using homo- and heterooligomers under denaturing and non-denaturing conditions. Homooligodeoxyribonucleotides of equal chain lengths but of different base composition showed significant differences in mobility. In addition, the migration properties of heterooligomers were found to be highly dependent on their base composition. A simple equation is presented for predicting relative migration times using denaturing and non-denaturing polyacrylamide capillary gel electrophoresis. Orange-G was used as an internal standard and as the basis of the relative migration time calculations. Examples are presented using homo- and heterooligomers in the 10-20-mer range to show the correlation of the primary structure and their predicted and observed migration rates.
引用
收藏
页码:297 / 303
页数:7
相关论文
共 14 条
[1]   DNA CHAIN-LENGTH MARKERS AND THE INFLUENCE OF BASE COMPOSITION ON ELECTROPHORETIC MOBILITY OF OLIGODEOXYRIBONUCLEOTIDES IN POLYACRYLAMIDE-GELS [J].
FRANK, R ;
KOSTER, H .
NUCLEIC ACIDS RESEARCH, 1979, 6 (06) :2069-2087
[2]   CAPILLARY ELECTROPHORESIS [J].
GORDON, MJ ;
HUANG, XH ;
PENTONEY, SL ;
ZARE, RN .
SCIENCE, 1988, 242 (4876) :224-228
[3]   ANALYTICAL AND MICROPREPARATIVE ULTRAHIGH RESOLUTION OF OLIGONUCLEOTIDES BY POLYACRYLAMIDE-GEL HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
GUTTMAN, A ;
COHEN, AS ;
HEIGER, DN ;
KARGER, BL .
ANALYTICAL CHEMISTRY, 1990, 62 (02) :137-141
[4]  
GUTTMAN A, 1991, American Biotechnology Laboratory, V9, P10
[5]  
GUTTMAN A, 1990, 14TH INT S COL LIQ C
[6]   SEPARATION OF DNA RESTRICTION FRAGMENTS BY HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS WITH LOW AND ZERO CROSS-LINKED POLYACRYLAMIDE USING CONTINUOUS AND PULSED ELECTRIC-FIELDS [J].
HEIGER, DN ;
COHEN, AS ;
KARGER, BL .
JOURNAL OF CHROMATOGRAPHY, 1990, 516 (01) :33-48
[7]   HIGH-PERFORMANCE ELECTROPHORESIS - ELIMINATION OF ELECTROENDOSMOSIS AND SOLUTE ADSORPTION [J].
HJERTEN, S .
JOURNAL OF CHROMATOGRAPHY, 1985, 347 (02) :191-198
[8]   CAPILLARY ZONE ELECTROPHORESIS [J].
JORGENSON, JW ;
LUKACS, KD .
SCIENCE, 1983, 222 (4621) :266-272
[9]   HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS IN THE BIOLOGICAL SCIENCES [J].
KARGER, BL ;
COHEN, AS ;
GUTTMAN, A .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 492 :585-614
[10]   HIGH-PERFORMANCE CAPILLARY ELECTROPHORESIS [J].
KARGER, BL .
NATURE, 1989, 339 (6226) :641-642