EVALUATION OF METHODS OF INTERNAL-FIXATION OF TRANSVERSE PATELLA FRACTURES - A BIOMECHANICAL STUDY

被引:83
作者
BURVANT, JG [1 ]
THOMAS, KA [1 ]
ALEXANDER, R [1 ]
HARRIS, MB [1 ]
机构
[1] LOUISIANA STATE UNIV,MED CTR,DEPT ORTHOPAED SURG,BIOENGN LAB,2025 GRAVIER ST,SUITE 400,NEW ORLEANS,LA 70112
关键词
BIOMECHANICS; INTERNAL FRACTURE FIXATION; FRACTURE; PATELLA;
D O I
10.1097/00005131-199404000-00012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Biomechanical testing was performed to evaluate five techniques of internal fixation of transverse patella fractures. Using cadaveric lower extremities, transverse osteotomies of the patella were performed, and the simulated fractures were fixed with the following techniques: the modified tension band, anterior tension band with a supplemental cerclage wire (the Pyrford technique), tension band with cancellous bone screws, Pyrford technique with cancellous screws, and cancellous screws alone. The fixation techniques were evaluated by measuring the separation of the fracture fragments during loading to produce a physiologic range of motion (90-degrees flexion to full extension). All techniques functioned adequately, with no fracture gap exceeding 1 mm. The tension band with screws technique performed significantly better than did the modified tension band, with an average fracture gap approximately half that of the traditional modified tension band technique. Mechanically, the addition of the screws to the tension band techniques reduces fracture separation by providing compression throughout the range of motion and by resisting the tensile loading during terminal extension.
引用
收藏
页码:147 / 153
页数:7
相关论文
共 11 条
[1]  
Bostman O., Kiviluoto O., Santavirta S., Et al., Fractures of the patella treated by operation, Arch Orthop Trauma Surg, 102, pp. 78-81, (1983)
[2]  
Buff H.-U., Jones L.C., Hungerford D.S., Experimental determination of forces transmitted through the patello-femoral joint, J Biomech, 21, pp. 17-23, (1988)
[3]  
Curtis M.J., Internal fixation for fractures of the patella: A comparison of two methods, J Bone Joint Surg [Br], 72, pp. 280-282, (1990)
[4]  
Enneking W.F., Horowitz M., The intra-articular effects of immobilization on the human knee, J Bone Joint Surg [Am], 54, pp. 973-985, (1972)
[5]  
Hungerford D.S., Barry M., Biomechanics of the patellofemoral joint, Clin Orthop, 144, pp. 9-15, (1979)
[6]  
Johnson E.E., Fractures of the knee part II: Fractures of the patella, Fractures in Adults, 2, pp. 1762-1777, (1991)
[7]  
Muller M.E., Allgower M., Schneider R., Willenegger H., Manual of Internal Fixation: Techniques Recommended by the AO Group, (1991)
[8]  
Perry C.R., McCarthy J.A., Kain C.C., Pearson R.L., Patellar fixation protected with a load-sharing cable: A mechanical and clinical study, J Orthop Trauma, 2, pp. 234-240, (1988)
[9]  
Reilly D.T., Martens M., Experimental analysis of the quadriceps muscle force and patello-femoral joint reaction force for various activities, Acta Orthop Scand, 43, pp. 126-137, (1972)
[10]  
Weber M.J., Janecki C.J., McLeod P., Nelson C.L., Thompson J.A., Efficacy of various forms of fixation of transverse fractures of the patella, J Bone Joint Surg [Am], 62, pp. 215-220, (1980)