FLOW-INJECTION ASSAY OF ENZYME-INHIBITION IN FISH USING IMMOBILIZED DIAMINE OXIDASE

被引:28
|
作者
HUNGERFORD, JM
AREFYEV, AA
机构
[1] Seafood Products Research Center, US Food and Drug Administration, Bothell, WA 98041-3012
关键词
FLOW SYSTEM; FLUOROMETRY; DIAMINE OXIDASE; ENZYME INHIBITION; ENZYME REACTOR; FISH; HISTAMINE;
D O I
10.1016/0003-2670(92)80213-Q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-injection assay for inhibition of diamine oxidase (DAO) is described. Histamine in decomposed fish is detected and used as the enzyme substrate. Sample extracts are doubly injected; one of the two resulting sample zones is passed through a reactor containing DAO immobilized to Sepharose. Histamine is detected sequentially in both the pristine and enzymatically treated zones. The detection chemistry (kinetics-optimized condensation with phthalic dicarboxaldehyde) allows the selective detection of histamine. Subsequent calibration with histamine standard and comparison of the two peak heights allows generic detection of compounds inhibiting the- DAO-mediated conversion of histamine. Preliminary data show that the system can detect inhibitors in extracts of decomposed Mahi-Mahi (associated with a Scombroid poisoning outbreak) and that far lower levels of inhibition are observed in fresh fish. Several known inhibitors and competitive substrates of DAO are also tested.
引用
收藏
页码:351 / 359
页数:9
相关论文
共 50 条
  • [31] UTILIZATION OF ADSORPTION-IMMOBILIZED UREASE IN GAS-DIFFUSION FLOW-INJECTION
    SPINKS, TL
    PACEY, GE
    ANALYTICA CHIMICA ACTA, 1990, 237 (02) : 503 - 508
  • [32] A SCREENING METHOD FOR TRACE MERCURY ANALYSIS USING FLOW-INJECTION WITH UREASE INHIBITION AND FLUORESCENCE DETECTION
    NARINESINGH, D
    MUNGAL, R
    NGO, TT
    ANALYTICA CHIMICA ACTA, 1994, 292 (1-2) : 185 - 190
  • [33] SPECTROFLUOROMETRIC FLOW-INJECTION DETERMINATION OF POTASSIUM IN SERUM BASED ON ENZYME ACTIVATION
    FERNANDEZROMERO, JM
    DECASTRO, MDL
    QUILESZAFRA, R
    ANALYTICA CHIMICA ACTA, 1995, 308 (1-3) : 178 - 186
  • [34] DETERMINATION OF MINUTE AMOUNTS OF ATP BY FLOW-INJECTION ANALYSIS USING ENZYME AMPLIFICATION REACTIONS AND FLUORESCENCE DETECTION
    HANSEN, EH
    GUNDSTRUP, M
    MIKKELSEN, HS
    JOURNAL OF BIOTECHNOLOGY, 1993, 31 (03) : 369 - 380
  • [35] RAPID SCREENING OF PORPHYRINS USING FLOW-INJECTION ANALYSIS AND VISIBLE LASER FLUOROMETRY
    HUIE, CW
    AIKEN, JH
    WILLIAMS, WR
    ANALYTICA CHIMICA ACTA, 1991, 254 (1-2) : 189 - 196
  • [36] Ultrasensitive flow-injection electrochemical method for determination of histamine in tuna fish samples
    Akbari-adergani, Behrouz
    Norouzi, Parviz
    Ganjali, Mohammad Reza
    Dinarvand, Rassoul
    FOOD RESEARCH INTERNATIONAL, 2010, 43 (04) : 1116 - 1122
  • [37] Flow-injection analysis for hypoxanthine in meat with dissolved oxygen detector and enzyme reactor
    Numata, M
    Funazaki, N
    Ito, S
    Asano, Y
    Yano, Y
    TALANTA, 1996, 43 (12) : 2053 - 2059
  • [38] FLOW-INJECTION DETERMINATION OF POLYPHENOLS USING A PLANT JUICE CARRIER
    UCHIYAMA, S
    SUZUKI, S
    ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) : 361 - 365
  • [39] FLOW-INJECTION SPECTROFLUOROMETRIC DETERMINATION OF SULFATE USING CALCEIN AND ZIRCONIUM
    CHIMPALEE, N
    CHIMPALEE, D
    SUPARUKNARI, S
    BOONYANITCHAYAKUL, B
    BURNS, DT
    ANALYTICA CHIMICA ACTA, 1994, 298 (03) : 401 - 404
  • [40] FLOW-INJECTION SPECTROPHOTOMETRIC DETERMINATION OF PHOSPHATE USING CRYSTAL VIOLET
    BURNS, DT
    CHIMPALEE, D
    CHIMPALEE, N
    ITTIPORNKUL, S
    ANALYTICA CHIMICA ACTA, 1991, 254 (1-2) : 197 - 200