Calculation of indirect-lightning flashover rate on distribution lines from indirect lightning in tropical zones

被引:0
|
作者
Soto-Rios, Edison [1 ]
Perez-Gonzalez, Ernesto [2 ]
del Rio-Trujillo, Diego [3 ]
机构
[1] Univ Ind Santander, Escuela Ingn Elect Elect & Telecomunicac, Grp Invest Sistemas Energia Elect GISEL, Bucaramanga, Colombia
[2] Univ Nacl Colombia, Dept Energia Elect & Automat, Programa Invest Adquisic & Anal Senales PAAS, Medellin, Colombia
[3] Univ Nacl Colombia, Dept Ingn Elect Elect & Comp, Manizales, Colombia
来源
UIS INGENIERIAS | 2018年 / 17卷 / 01期
关键词
Lightning parameters; flashover rate; distribution lines; lightning induced voltages; CIGRE; MCS;
D O I
10.18273/revuin.v17n1-2018021
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper the indirect-lightning flashover rate of a distribution line is obtained following the procedure described in the IEEE Std. 1410 - 2010, but using other parameters of the first stroke distributions (peak current and front time) adopted by CIGRE. These parameters were taken from the measured currents of the Morro do Cachimbo Station in Belo Horizonte - Brazil, which are representative of the tropical zone. As a result, the calculated flashover rate with the data of tropical zone is higher than one obtained with the CIGRE curves. Such increments could be in the most extreme case of 70%.
引用
收藏
页码:217 / 222
页数:6
相关论文
共 50 条
  • [31] ALGORITHMS FOR CALCULATION OF LIGHTNING-INDUCED VOLTAGES ON DISTRIBUTION LINES
    ANDERSON, JG
    SHORT, TA
    HILEMAN, AR
    IEEE TRANSACTIONS ON POWER DELIVERY, 1993, 8 (03) : 1217 - 1225
  • [32] Characterization of Indirect Coupling Mechanisms from Lightning to Underground Cavities
    Higgins, Matthew B.
    Caldwell, Michele
    Morris, Marv
    2008 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM, VOLS 1-9, 2008, : 903 - +
  • [33] Analysis of flashover rate by lightning in Korea distribution line using CRIEPI method
    Seo, H.-C. (hunchull2@skku.edu), 1600, Korean Institute of Electrical Engineers (62):
  • [34] Selection of the Lateral Distance for the Assessment Area in a Monte Carlo Procedure Under Indirect Lightning for Overhead Distribution Lines
    Cao, Jinxin
    Andreotti, Amedeo
    Du, Yaping
    Ravichandran, Nagananthini
    Ding, Yuxuan
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2023, 65 (03) : 935 - 939
  • [35] Influence of ground conductivity on the over voltages induced on overhead power distribution lines due to an indirect lightning stroke
    Kannu, PD
    Thomas, J
    2000 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, VOLS 1 AND 2, SYMPOSIUM RECORD, 2000, : 949 - 954
  • [37] OPERATING DUTY OF DISTRIBUTION SURGE ARRESTERS DUE TO INDIRECT LIGHTNING STRIKES.
    Stringfellow, M.F.
    Transactions of the South African Institute of Electrical Engineers, 1981, 72 (pt 5): : 102 - 122
  • [38] A Semi-Analytical Formula for the Fvaluation of the Indirect Lightning Performance of Overhead Power Lines
    Brignone, Massimo
    Delfino, Federico
    Procopio, Renato
    Rossi, Mansueto
    Rachidi, Farhad
    2014 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC EUROPE), 2014, : 560 - 564
  • [39] Effect of Rusck's Approximation on the Indirect Lightning Performance Assessment of Aerial Power Lines
    Barbosa, Celio Fonseca
    Paulino, Jose Osvaldo Saldanha
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2021, 63 (01) : 181 - 188
  • [40] Simulation calculation and analysis of lightning induced overvoltage on power distribution lines
    Yu, Zhanqing
    Zeng, Rong
    Wang, Shao'an
    Lu, Guojun
    Xiong, Jun
    Liu, Yu
    Gaodianya Jishu/High Voltage Engineering, 2013, 39 (02): : 415 - 422