Calculation of indirect-lightning flashover rate on distribution lines from indirect lightning in tropical zones

被引:0
|
作者
Soto-Rios, Edison [1 ]
Perez-Gonzalez, Ernesto [2 ]
del Rio-Trujillo, Diego [3 ]
机构
[1] Univ Ind Santander, Escuela Ingn Elect Elect & Telecomunicac, Grp Invest Sistemas Energia Elect GISEL, Bucaramanga, Colombia
[2] Univ Nacl Colombia, Dept Energia Elect & Automat, Programa Invest Adquisic & Anal Senales PAAS, Medellin, Colombia
[3] Univ Nacl Colombia, Dept Ingn Elect Elect & Comp, Manizales, Colombia
来源
UIS INGENIERIAS | 2018年 / 17卷 / 01期
关键词
Lightning parameters; flashover rate; distribution lines; lightning induced voltages; CIGRE; MCS;
D O I
10.18273/revuin.v17n1-2018021
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper the indirect-lightning flashover rate of a distribution line is obtained following the procedure described in the IEEE Std. 1410 - 2010, but using other parameters of the first stroke distributions (peak current and front time) adopted by CIGRE. These parameters were taken from the measured currents of the Morro do Cachimbo Station in Belo Horizonte - Brazil, which are representative of the tropical zone. As a result, the calculated flashover rate with the data of tropical zone is higher than one obtained with the CIGRE curves. Such increments could be in the most extreme case of 70%.
引用
收藏
页码:217 / 222
页数:6
相关论文
共 50 条
  • [21] Response of distribution networks to direct and indirect lightning: Influence of surge arresters location, flashover occurrence and environmental shielding
    Borghetti, Alberto
    Napolitano, Fabio
    Nucci, Carlo Alberto
    Tossani, Fabio
    ELECTRIC POWER SYSTEMS RESEARCH, 2017, 153 : 73 - 81
  • [22] Electromagnetic compatibility problems of indirect lightning stroke on Overhead Power Lines
    M'ziou, Nassima
    MATHEMATICS AND COMPUTERS IN SIMULATION, 2020, 167 (167) : 429 - 442
  • [23] Frequency domain modeling of nonuniform multiconductor lines excited by indirect lightning
    Gomez, Pablo
    Escamilla, Juan C.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2013, 45 (01) : 420 - 426
  • [24] Calculation of lightning induced overvoltage on overhead distribution lines
    Beijing Key Laboratory of High Voltage and EMC , Changping District, Beijing 102206, China
    不详
    不详
    Zhongguo Dianji Gongcheng Xuebao, 2012, 31 (191-199):
  • [25] Indirect Lightning Performance of a Real Distribution Network with focus on Transformer Protection
    Borghetti, Alberto
    Napolitano, Fabio
    Nucci, Carlo Alberto
    Tossani, Fabio
    Dos Santos, Gilnei J. G.
    Fagundes, Donorvan R.
    Lopes, Gustavo P.
    Martinez, Manuel L. B.
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 1884 - 1890
  • [26] Procedure for Protection of Distribution Feeder against Induced Voltages by Indirect Lightning
    Araujo, M. A.
    Flauzino, R. A.
    Batista, O. E.
    Moraes, L. A.
    2015 INTERNATIONAL SYMPOSIUM ON LIGHTNING PROTECTION (XIII SIPDA), 2015, : 264 - 269
  • [27] Effect of protected on unprotected circuits in case of indirect lightning flashes to overhead lines
    Kisielewicz, T.
    Lo Piparo, G. B.
    Mazzetti, C.
    2018 IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2018 IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC / I&CPS EUROPE), 2018,
  • [28] Numerical calculation of lightning induced voltages on overhead distribution lines
    Wuhan Univ of Hydraulic and Electric, Engineering, Wuhan, China
    Zhongguo Dianji Gongcheng Xuebao, 4 (299-301):
  • [29] A Flashover Rate of Grounding Resistance for Lightning Arrestor in 22.9 kV Distribution Systems
    Choi S.-K.
    Transactions of the Korean Institute of Electrical Engineers, 2023, 72 (04): : 559 - 565
  • [30] Calculation of Lightning-induced Voltages for Power Distribution Lines
    Fu, Jingwei
    An, Jianwei
    Liu, Gang
    Li, Te
    Xie, Shijun
    Deng, Jun
    Zhuang, Chijie
    He, Jinliang
    2018 34TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP 2018), 2018,