SIMULTANEOUS DETERMINATION OF 8 ANTICOAGULANT RODENTICIDES IN BLOOD-SERUM AND LIVER

被引:66
作者
CHALERMCHAIKIT, T [1 ]
FELICE, LJ [1 ]
MURPHY, MJ [1 ]
机构
[1] UNIV MINNESOTA,COLL VET MED,DEPT VET DIAGNOST MED,1943 CARTER AVE,ST PAUL,MN 55108
关键词
D O I
10.1093/jat/17.1.56
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A liquid chromatographic method was developed for the analysis of indandione and 4-hydroxycoumarin anticoagulant rodenticides in blood serum and liver. The method enabled the measurement of serum and liver concentrations of eight anticoagulant rodenticides: Brodifacoum, bromadiolone, chlorophacinone, coumafuryl, coumatetralyl, diphacinone, difenacoum, and warfarin. Anticoagulants were extracted from serum and liver with acetonitrile. Extracts were applied to solid-phase extraction columns, which contained mixed packings. Column eluates were evaporated to dryness, reconstituted, and subjected to reversed-phase liquid chromatography. Hydroxycoumarins were detected by fluorescence at an excitation wavelength of 318 nm and an emission wavelength of 390 nm. Indandiones were detected by UV absorption at 285 nm. Extraction efficiencies of greater than 75% for serum and greater than 69% for liver were obtained. The within-run precision (CV) ranged from 2.4 to 8.6% for serum and 2.6 to 8.7% for liver. The between-run precision (CV) ranged from 1.5 to 12.2% for serum and from 2.1 to 11.8% for liver. Hydroxycoumarin rodenticides were detected at 1 ng/mL of serum and 1 ng/g of liver. Indandiones were detected at 10 ng/mL of serum and 10 ng/g of liver. © 1993 Oxford University Press.
引用
收藏
页码:56 / 61
页数:6
相关论文
共 16 条
[1]  
ADDISON JB, 1982, J ASSOC OFF ANA CHEM, V65, P1299
[2]   DETERMINATION OF CHLOROPHACINONE AND DIPHENADIONE RESIDUES IN BIOLOGICAL-MATERIALS [J].
BULLARD, RW ;
HOLGUIN, G ;
PETERSON, JE .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1975, 23 (01) :72-74
[3]  
Burocoa Ch, 1989, CLIN TOXICOL, V27, P78
[4]  
DuVall M D, 1989, J Vet Diagn Invest, V1, P66
[5]   MULTICOMPONENT DETERMINATION OF 4-HYDROXYCOUMARIN ANTICOAGULANT RODENTICIDES IN BLOOD-SERUM BY LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
FELICE, LJ ;
CHALERMCHAIKIT, T ;
MURPHY, MJ .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1991, 15 (03) :126-129
[6]   REVERSED-PHASE ION-PAIR LIQUID-CHROMATOGRAPHIC DETERMINATION OF CHLOROPHACINONE RESIDUES IN ANIMAL-TISSUES [J].
HUNTER, K .
JOURNAL OF CHROMATOGRAPHY, 1984, 299 (02) :405-414
[7]   DETERMINATION OF COUMARIN ANTICOAGULANT RODENTICIDE RESIDUES IN ANIMAL TISSUE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .1. FLUORESCENCE DETECTION USING POST-COLUMN TECHNIQUES [J].
HUNTER, K .
JOURNAL OF CHROMATOGRAPHY, 1983, 270 (NOV) :267-276
[8]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC STRATEGIES FOR THE DETERMINATION AND CONFIRMATION OF ANTICOAGULANT RODENTICIDE RESIDUES IN ANIMAL-TISSUES [J].
HUNTER, K .
JOURNAL OF CHROMATOGRAPHY, 1985, 321 (02) :255-272
[9]  
JONES EC, 1984, JAMA-J AM MED ASSOC, V252, P3005, DOI 10.1001/jama.252.21.3005
[10]   DETERMINATION OF BRODIFACOUM IN ANIMAL-TISSUES BY HPLC [J].
KIEBOOM, AJ ;
RAMMELL, CG .