STRENGTH AND KINEMATIC RESPONSE OF DYNAMIC CERVICAL-SPINE INJURIES

被引:30
作者
YOGANANDAN, N
PINTAR, FA
SANCES, A
REINARTZ, J
LARSON, SJ
机构
[1] Department of Neurosurgery, Medical College of Wisconsin, Milwaukee, WI
[2] Department of Veterans Affairs Medical Center, Milwaukee, WI
[3] Department of Biomedical Engineering, Marquette University, Milwaukee, WI
关键词
BIODYNAMICS; LOCALIZED KINEMATICS; STRAIN RATE; CERVICAL SPINE; HEAD NECK COMPLEX; COMPRESSION;
D O I
10.1097/00007632-199110001-00011
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
This study was conducted to evaluate the biodynamic strength and localized kinematic response of the human cervical spine under axial loading applied to the head. Intact ligamentous fresh human cadaveric head-neck complexes were subjected to dynamic compressive forces with a custom-designed electrohydraulic testing device at varying rates. The structure included the effects of anterior and posterior cervical spine muscles with a system of pulleys, dead weights, and spring tension. Localized kinematic data were obtained from retroreflective targets placed on the bony landmarks of the specimen at every level of the spinal column. Input forces, accelerations, displacement, and output generalized force histories were recorded as a function of time with a digital data acquisition system at dynamic sampling rates in excess of 8,000 Hz. High-speed photography at 1,000-1,200 frames/sec also was used. Pathologic alterations to the head-neck complex were evaluated with conventional radiography, computed tomography, and cryomicrotomy. In all specimens, cervical spine injuries occurred as a result of impact. Compressive forces recorded at the distal end of the preparation indicated large-duration, short-magnitude pulses in contrast to short-duration, high-amplitude input waveforms at the head, suggesting decoupling characteristics of the head-neck system. Cervical vertebral body accelerations were consistently smaller than the accelerations recorded on the head. Kinematic data demonstrated temporal deformation characteristics as well as a plausible sequence of spinal deformations leading to injury, which were correlated with the pathoanatomic alterations documented with the post-test computed tomographic and sequential cryomicrotome sections.
引用
收藏
页码:S511 / S517
页数:7
相关论文
共 31 条
[1]  
Alem N.M., Nusholtz G.S., Melvin J.W., Head and Neck Response Io Axial Impacts, pp. 275-288, (1984)
[2]  
Anderson D.W., McLaurin R.L., The national head and spinal cord injury survey, J Neurosurg, 53, (1980)
[3]  
Injury in America, pp. 1-37, (1985)
[4]  
Cusick J.F., Yoganandan N., Pintar F., Myklebust J., Hussain H., Biomechanics of cervical spine facetectomy and fixation techniques, Spine, 13, pp. 808-812, (1988)
[5]  
Dai Q.G., Liu Y.K., Failure analysis of a beam-column with simulated muscle tractions: Potential failure surfaces for spinal trauma, Adv Bioeng, 17, pp. 253-256, (1990)
[6]  
Hirsch C., Galante J., Laboratory conditions for tensile tests in annulus fibrosus from human intervertebral discs, Acta Orthop Scand, (1967)
[7]  
Kalsbeek W.D., McLaurin R.L., Harris B.S., Miller J.D., The national head and spinal cord injury survey: Major findings, J Neurosurg, 53, (1980)
[8]  
Kraus J.F., Franti C.E., Riggins R.S., Richards D., Borhani N.O., Incidence of traumatic spinal cord lesions, J Chron Dis, 28, pp. 471-492, (1975)
[9]  
Kraus J.F., Epidemiological Aspects of Acute Spinal Cord Injury: A Review of Incidence, Prevalence, Causes, and Outcome. Central Nervous System Trauma Status Report—1985, pp. 313-322, (1985)
[10]  
Liu Y.K., Dai Q.G., The second stiffest axis of a beam-column: Implications for cervical spine trauma, Jbiomech Eng, 111, pp. 122-127, (1989)