MR-IMAGING WITH HYPERPOLARIZED HE-3 GAS

被引:319
作者
MIDDLETON, H
BLACK, RD
SAAM, B
CATES, GD
COFER, GP
GUENTHER, R
HAPPER, W
HEDLUND, LW
JOHNSON, GA
JUVAN, K
SWARTZ, J
机构
[1] DUKE UNIV,MED CTR,CTR IN VIVO MICROSCOPY,DURHAM,NC
[2] DUKE UNIV,DEPT BIOMED ENGN,DURHAM,NC 27706
[3] DUKE UNIV,DEPT PHYS,DURHAM,NC 27706
关键词
MRI; GAS; HELIUM; HYPERPOLARIZED;
D O I
10.1002/mrm.1910330219
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance images of the lungs of a guinea pig have been produced using hyperpolarized helium as the source of the MR signal. The resulting images are not yet sufficiently optimized to reveal fine structural detail within the lung, but the spectacular signal from this normally signal-deficient organ system offers great promise for eventual in vivo imaging experiments. Fast 2D and 3D GRASS sequences with very small flip angles were employed to conserve the nonrenewable longitudinal magnetization. We discuss various unique features associated with performing MRI with hyperpolarized gases, such as the selection of the noble gas species, polarization technique, and constraints on the MR pulse sequence.
引用
收藏
页码:271 / 275
页数:5
相关论文
共 24 条
  • [1] ALBERT MS, 1994, NATURE, V370, P199, DOI 10.1038/370199a0
  • [2] DETERMINATION OF THE NEUTRON SPIN STRUCTURE-FUNCTION
    ANTHONY, PL
    ARNOLD, RG
    BAND, HR
    BOREL, H
    BOSTED, PE
    BRETON, V
    CATES, GD
    CHUPP, TE
    DIETRICH, FS
    DUNNE, J
    ERBACHER, R
    FELLBAUM, J
    FONVIEILLE, H
    GEARHART, R
    HOLMES, R
    HUGHES, EW
    JOHNSON, JR
    KAWALL, D
    KEPPEL, C
    KUHN, SE
    LOMBARDNELSEN, RM
    MARRONCLE, J
    MARUYAMA, T
    MEYER, W
    MEZIANI, ZE
    MIDDLETON, H
    MORGENSTERN, J
    NEWBURY, NR
    PETRATOS, GG
    PITTHAN, R
    PREPOST, R
    ROBLIN, Y
    ROCK, SE
    ROKNI, SH
    SHAPIRO, G
    SMITH, T
    SOUDER, PA
    SPENGOS, M
    STALEY, F
    STUART, LM
    SZALATA, ZM
    TERRIEN, Y
    THOMPSON, AK
    WHITE, JL
    WOODS, M
    XU, J
    YOUNG, CC
    ZAPALAC, G
    [J]. PHYSICAL REVIEW LETTERS, 1993, 71 (07) : 959 - 962
  • [3] A HIGH-TEMPERATURE SUPERCONDUCTING RECEIVER FOR NUCLEAR-MAGNETIC-RESONANCE MICROSCOPY
    BLACK, RD
    EARLY, TA
    ROEMER, PB
    MUELLER, OM
    MOGROCAMPERO, A
    TURNER, LG
    JOHNSON, GA
    [J]. SCIENCE, 1993, 259 (5096) : 793 - 795
  • [4] NUCLEAR POLARIZATION IN HE-3 GAS INDUCED BY OPTICAL PUMPING AND DIPOLAR EXCHANGE
    BOUCHIAT, MA
    CARVER, TR
    VARNUM, CM
    [J]. PHYSICAL REVIEW LETTERS, 1960, 5 (08) : 373 - 375
  • [5] DIFFUSION-LIMITED RESOLUTION IN NUCLEAR MAGNETIC-RESONANCE MICROSCOPY
    CALLAGHAN, PT
    ECCLES, CD
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1988, 78 (01): : 1 - 8
  • [6] LASER PRODUCTION OF LARGE NUCLEAR-SPIN POLARIZATION IN FROZEN XENON
    CATES, GD
    BENTON, DR
    GATZKE, M
    HAPPER, W
    HASSON, KC
    NEWBURY, NR
    [J]. PHYSICAL REVIEW LETTERS, 1990, 65 (20) : 2591 - 2594
  • [7] NUCLEAR MAGNETIC-RESONANCE MICROSCOPY WITH 4-MU-M RESOLUTION - THEORETICAL-STUDY AND EXPERIMENTAL RESULTS
    CHO, ZH
    AHN, CB
    JUH, SC
    LEE, HK
    JACOBS, RE
    LEE, S
    YI, JH
    JO, JM
    [J]. MEDICAL PHYSICS, 1988, 15 (06) : 815 - 824
  • [8] POLARIZED, HIGH-DENSITY, GASEOUS HE-3 TARGETS
    CHUPP, TE
    WAGSHUL, ME
    COULTER, KP
    MCDONALD, AB
    HAPPER, W
    [J]. PHYSICAL REVIEW C, 1987, 36 (06): : 2244 - 2251
  • [9] POLARIZATION OF NE-21 BY SPIN EXCHANGE WITH OPTICALLY PUMPED RB VAPOR
    CHUPP, TE
    COULTER, KP
    [J]. PHYSICAL REVIEW LETTERS, 1985, 55 (10) : 1074 - 1077
  • [10] SIMPLE PROTON SPECTROSCOPIC IMAGING
    DIXON, WT
    [J]. RADIOLOGY, 1984, 153 (01) : 189 - 194