THE HOLDING STRENGTH OF CANNULATED SCREWS COMPARED WITH SOLID CORE SCREWS IN CORTICAL AND CANCELLOUS BONE

被引:33
|
作者
LEGGON, R [1 ]
LINDSEY, RW [1 ]
DOHERTY, BJ [1 ]
ALEXANDER, J [1 ]
NOBLE, P [1 ]
机构
[1] BAYLOR COLL MED,DEPT ORTHOPAED SURG,6550 FANNIN,SUITE 2625,HOUSTON,TX 77030
关键词
CANNULATED SCREW VERSUS SOLID CORE SCREW; CORTICAL BONE; CANCELLOUS BONE;
D O I
10.1097/00005131-199310000-00008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The comparative holding strength of cannulated screws (CS) versus solid core screws (SCS) has not been reported, although differences exist in the respective diameters of their outer thread and pilot drill holes. Our objectives were to characterize these differences and determine the holding power of CS compared with SCS in cortical and cancellous bone. The dimensions of the Synthes (Paoli, PA) 3.5-mm SCS, 3.5-mm CS, 6.5-mm SCS, and 7.0-mm CS were measured, and the cross-sectional area for thread purchase was calculated. Using adult canine femurs, small-fragment 3.5-mm SCS were inserted in cortical (midshaft) and cancellous (condyle) bone of one limb, and CS were placed in similar locations in the contralateral limb. The same technique was used for large-fragment CS and SCS. Pull-out testing was performed using an MTS machine (MTS Systems, Minneapolis, MN) with axial loads applied at 5 mm/s, and data were analyzed to determine the effects of screw type, location, and size. Differences in CS versus SCS design result in higher cross-sectional areas available for SCS thread purchase. Yet no significant differences exists between screw types (SCS vs. CS) in either cortical or cancellous bone. In cancellous bone, large-fragment screws required more force to pull out than did small screws (p = 0.000). The mean force required to pull out small-fragment screws was higher in cortical bone than in cancellous bone (p = 0.000). These data suggest that the clinical decision to use CS versus SCS should not be based on pull-out strength.
引用
收藏
页码:450 / 457
页数:8
相关论文
共 50 条
  • [1] Effect of cortical thickness and cancellous bone density on the holding strength of internal fixator screws
    Seebeck, J
    Goldhahn, J
    Städele, H
    Messmer, P
    Morlock, MM
    Schneider, E
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2004, 22 (06) : 1237 - 1242
  • [3] Pullout strengths of cannulated and noncannulated cancellous bone screws
    Thompson, JD
    Benjamin, JB
    Szivek, JA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1997, (341) : 241 - 249
  • [4] Cancellous Screws Are Biomechanically Superior to Cortical Screws in Metaphyseal Bone
    Wang, Tim
    Boone, Christopher
    Behn, Anthony W.
    Ledesma, Justin B.
    Bishop, Julius A.
    ORTHOPEDICS, 2016, 39 (05) : E828 - E832
  • [5] Pullout strength of 2.0 mm cancellous and cortical screws in synthetic bone
    Moser, John E.
    Kunkel, Kevin A. R.
    Gerard, Patrick D.
    VETERINARY SURGERY, 2017, 46 (08) : 1110 - 1115
  • [6] HOLDING POWER AND REINFORCEMENT OF CANCELLOUS SCREWS IN HUMAN BONE
    KLEEMAN, BC
    TAKEUCHI, T
    GERHART, TN
    HAYES, WC
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1992, (284) : 260 - 266
  • [7] Mechanical performance of standard and cannulated 4.0 mm cancellous bone screws
    Brown, Greg A.
    McCarthy, Tracey
    Bourgeault, Craig A.
    Callahan, Dennis J.
    American Society of Mechanical Engineers, Bioengineering Division (Publication) BED, 1999, 42 : 581 - 582
  • [8] Factors affecting the pullout strength of cancellous bone screws
    Chapman, JR
    Harrington, RM
    Lee, KM
    Anderson, PA
    Tencer, AF
    Kowalski, D
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (03): : 391 - 398
  • [9] Factors affecting the pullout strength of cancellous bone screws
    Chapman, J.R.
    Harrington, R.M.
    Lee, K.M.
    Anderson, P.A.
    Tencer, A.F.
    Kowalski, D.
    Journal of Biomechanical Engineering, 1996, 118 (03): : 391 - 398
  • [10] LABORATORY COMPARISON OF THE CANNULATED HERBERT BONE SCREW WITH ASIF CANCELLOUS LAG SCREWS
    MARSHALL, PD
    EVANS, PD
    RICHARDS, J
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (01): : 89 - 92