BORON UPTAKE IN SUNFLOWER, SQUASH AND CULTURED TOBACCO CELLS - STUDIES WITH STABLE-ISOTOPE AND ICP-MS

被引:3
|
作者
BROWN, PH
HU, H
机构
[1] Department of Pomology, University of California, Davis, 95616, CA
关键词
CUCURBITA PEPO; HELIANTHUS ANNUUS; NICOTIANA TABACCUM;
D O I
10.1007/BF00025005
中图分类号
S3 [农学(农艺学)];
学科分类号
0901 ;
摘要
Boron uptake was studied with the use of stable B isotope and ICP-MS. Plant responses to changes in B concentration or temperature as well as respiratory inhibitors all suggest that B uptake is a passive, non-metabolic process.
引用
收藏
页码:147 / 150
页数:4
相关论文
共 50 条
  • [31] Matrix effects and mass bias caused by inorganic acids on boron isotope determination by multi-collector ICP-MS
    Chen, Xuefei
    Zhang, Le
    Wei, Gangjian
    Ma, Jinlong
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (12) : 2410 - 2417
  • [32] Application of stable isotopes in environmental tracer studies – Measurement of monomethylmercury (CH3Hg+) by isotope dilution ICP-MS and detection of species transformation
    H. Hintelmann
    R. D. Evans
    Fresenius' Journal of Analytical Chemistry, 1997, 358 : 378 - 385
  • [33] Application of stable isotopes in environmental tracer studies - Measurement of monomethylmercury (CH3Hg+) by isotope dilution ICP-MS and detection of species transformation
    Hintelmann, H
    Evans, RD
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 358 (03): : 378 - 385
  • [34] Precise measurement of stable potassium isotope ratios using a single focusing collision cell multi-collector ICP-MS
    Li, Weiqiang
    Beard, Brian L.
    Li, Shilei
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (04) : 1023 - 1029
  • [35] Chemometric authentication of Pu'er teas in terms of multielement stable isotope ratios analysis by EA-IRMS and ICP-MS
    Liu, Honglin
    Zeng, Yitao
    Zhao, Xin
    Tong, Huarong
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2020, 28 (02) : 54 - 66
  • [36] ICP-MS Measurement of 11B/10B Isotope Ratios in Grapevine Leaves and the Investigation of Possible Boron Isotope Fractionation in Grapevine Plants
    Coetzee, P. P.
    Greeff, L.
    Vanhaecke, F.
    SOUTH AFRICAN JOURNAL OF ENOLOGY AND VITICULTURE, 2011, 32 (01) : 28 - 34
  • [37] The utility of rapid throughput single-collector sector-field ICP-MS for soil Pb isotope studies
    Desem, Candan Ulgen
    Maas, Roland
    Woodhead, Jon
    Carr, Graham
    Greig, Alan
    APPLIED GEOCHEMISTRY, 2022, 142
  • [38] An assessment of the accuracy of stable Fe isotope ratio measurements on samples with organic and inorganic matrices by high-resolution multicollector ICP-MS
    Schoenberg, R
    von Blanckenburg, F
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2005, 242 (2-3) : 257 - 272
  • [39] Applications of hydrogen as a collision and reaction cell gas for enhanced measurement capability applied to low level stable and radioactive isotope detection using ICP-MS/MS
    Russell, B.
    Goddard, S. L.
    Mohamud, H.
    Pearson, O.
    Zhang, Y.
    Thompkins, H.
    Brown, R. J. C.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (12) : 2704 - 2714
  • [40] Uptake of antitumor platinum(II)-complexes by cancer cells, assayed by inductively coupled plasma mass spectrometry (ICP-MS)
    Ghezzi, A
    Aceto, M
    Cassino, C
    Gabano, E
    Osella, D
    JOURNAL OF INORGANIC BIOCHEMISTRY, 2004, 98 (01) : 73 - 78