SOLIDS FLOW IMAGING AND ATTRITION STUDIES IN A PNEUMATIC CONVEYOR

被引:55
作者
MCKEE, S [1 ]
DYAKOWSKI, T [1 ]
WILLIAMS, RA [1 ]
BELL, TA [1 ]
ALLEN, T [1 ]
机构
[1] DUPONT CO INC,NEWARK,DE 19714
关键词
ATTRITION STUDIES; PNEUMATIC CONVEYOR; SOLIDS FLOW IMAGING; TOMOGRAPHY; CAPACITANCE SENSORS;
D O I
10.1016/0032-5910(94)02894-T
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This work describes the first application of a non-invasive capacitance tomographic technique to monitoring the behaviour of industrial-scale pneumatic conveyors. Dynamic images of the solids distribution within a pipe have captured the movement of slugs in dense-phase solids conveying, and the presence of saltation in dilute-phase conveying. It has also been possible to acquire images downstream of a pipe bend and to use this information to establish a suitable location for obtaining a representative sample of a material stream. The information provided by cross-sectional images facilitates the validation of theoretical models and ultimately will allow improved design as the sensitivity and resolution of the technique are enhanced. A study of particle (sea salt) attrition is reported using a conveying line 32 m in length. It is demonstrated that particle breakage can be described as a function of the conveying velocity and solids-gas loading factor. Particle breakage is described in terms of the mass-specific surface area, and is seen to increase with conveying velocity. Particle breakage rates are found to be inversely related to the solids loading factor.
引用
收藏
页码:105 / 113
页数:9
相关论文
共 12 条
[1]   DETERMINATION OF COMPOSITION AND MOTION OF MULTICOMPONENT MIXTURES IN PROCESS VESSELS USING ELECTRICAL-IMPEDANCE TOMOGRAPHY .1. PRINCIPLES AND PROCESS ENGINEERING APPLICATIONS [J].
DICKIN, FJ ;
WILLIAMS, RA ;
BECK, MS .
CHEMICAL ENGINEERING SCIENCE, 1993, 48 (10) :1883-1897
[2]   INFLUENCE OF PROCESSING CONDITIONS ON ATTRITION OF NACL-CRYSTALS [J].
GHADIRI, M ;
YUREGIR, KR ;
POLLOCK, HM ;
ROSS, JDJ ;
ROLFE, N .
POWDER TECHNOLOGY, 1991, 65 (1-3) :311-320
[3]   TOMOGRAPHIC IMAGING OF 2-COMPONENT FLOW USING CAPACITANCE SENSORS [J].
HUANG, SM ;
PLASKOWSKI, AB ;
XIE, CG ;
BECK, MS .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1989, 22 (03) :173-177
[4]   DESIGN OF SENSOR ELECTRONICS FOR ELECTRICAL CAPACITANCE TOMOGRAPHY [J].
HUANG, SM ;
XIE, CG ;
THORN, R ;
SNOWDEN, D ;
BECK, MS .
IEE PROCEEDINGS-G CIRCUITS DEVICES AND SYSTEMS, 1992, 139 (01) :83-88
[5]  
MARCUS R, 1990, PNEUMATIC CONVEYING
[6]  
MCKEE SL, 1992, THESIS U MANCHESTER
[7]  
MILLS D, 1990, PNEUMATIC CONVEYING
[8]  
ROSE HE, 1969, ENGINEER, V22, P478
[9]   NUCLEAR MAGNETIC-RESONANCE IMAGING [J].
ROTHWELL, WP .
APPLIED OPTICS, 1985, 24 (23) :3958-3968
[10]  
Thorn R., 1990, Flow Measurement and Instrumentation, V1, P259, DOI 10.1016/0955-5986(90)90024-2