ONLINE REPOSITIONING DURING TREATMENT OF THE PROSTATE - A STUDY OF POTENTIAL LIMITS AND GAINS

被引:64
作者
BALTER, JM [1 ]
CHEN, GTY [1 ]
PELIZZARI, CA [1 ]
KRISHNASAMY, S [1 ]
RUBIN, S [1 ]
VIJAYAKUMAR, S [1 ]
机构
[1] UNIV CHICAGO,DEPT RADIAT & CELLULAR ONCOL,CHICAGO,IL 60637
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1993年 / 27卷 / 01期
关键词
IMAGE REGISTRATION; PRECISION RADIOTHERAPY; ONLINE IMAGING; SETUP ERROR; PATIENT REPOSITIONING;
D O I
10.1016/0360-3016(93)90431-T
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: With on-line portal imaging devices and image registration tools, the verification of radiation field position Prior to each treatment becomes technically feasible. In this paper, we analyze the impact of pre-treatment verification and field position adjustment on target coverage and normal tissue sparing. Methods and Materials: Port films were compared with corresponding simulation films to determine the magnitude of setup variations in patients treated for prostate cancer. From these data, an analytic function was determined between geometric coverage of the target and field margin size. A paradigm for on-line patient repositioning was employed to generate a new relationship between margin and target coverage. Margins were selected for the situations of normal treatment and on-line repositioning to ensure target coverage. Dose-volume histograms were generated for a typical prostate treatment using these margins. Results: On-line repositioning, when setup errors exceed 1 cm, results in a 6 mm reduction in margin, suggesting that 10% of the volume of bladder and rectum may be spared of high dose. Conclusion: The use of on-line imaging and image registration to guide adjustment of patient setup may lead to a eduction in the volume of normal tissues irradiated, and possibly improve the probability of complication-free survival in future treatments.
引用
收藏
页码:137 / 143
页数:7
相关论文
共 11 条
[1]  
BALTER J, 1990, International Journal of Radiation Oncology, Biology, Physics, V19, P168, DOI 10.1016/0360-3016(90)90736-4
[2]   CORRELATION OF PROJECTION RADIOGRAPHS IN RADIATION-THERAPY USING OPEN CURVE SEGMENTS AND POINTS [J].
BALTER, JM ;
PELIZZARI, CA ;
CHEN, GTY .
MEDICAL PHYSICS, 1992, 19 (02) :329-334
[3]  
Dryzmala RD, 1991, INT J RADIAT ONCOL, V21, P71
[4]   CALCULATION OF THE UNCERTAINTY IN THE DOSE DELIVERED DURING RADIATION-THERAPY [J].
GOITEIN, M .
MEDICAL PHYSICS, 1985, 12 (05) :608-612
[5]   A METHOD TO ANALYZE 2-DIMENSIONAL DAILY RADIOTHERAPY PORTAL IMAGES FROM AN ONLINE FIBEROPTIC IMAGING-SYSTEM [J].
GRAHAM, ML ;
CHENG, AY ;
GEER, LY ;
BINNS, WR ;
VANNIER, MW ;
WONG, JW .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (03) :613-619
[6]   VISUALIZATION OF INTERNAL MOTION WITHIN A TREATMENT PORTAL DURING A RADIATION-THERAPY TREATMENT [J].
LEONG, JC ;
STRACHER, MA .
RADIOTHERAPY AND ONCOLOGY, 1987, 9 (02) :153-156
[7]   EFFECT OF IMMOBILIZATION ON LOCALIZATION ERROR IN RADIOTHERAPY OF HEAD AND NECK CANCER [J].
MARKS, JE ;
HAUS, AG .
CLINICAL RADIOLOGY, 1976, 27 (02) :175-177
[8]   A METHOD FOR THE MEASUREMENT OF FIELD PLACEMENT ERRORS IN DIGITAL PORTAL IMAGES [J].
MEERTENS, H ;
BIJHOLD, J ;
STRACKEE, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (03) :299-323
[9]  
SHALEV S, 1990, MED PHYS, V17, P554
[10]   A MATRIX IONIZATION-CHAMBER IMAGING DEVICE FOR ONLINE PATIENT SETUP VERIFICATION DURING RADIOTHERAPY [J].
VANHERK, M ;
MEERTENS, H .
RADIOTHERAPY AND ONCOLOGY, 1988, 11 (04) :369-378