OPTIMIZATION OF SLURRY NEBULIZATION INDUCTIVELY-COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY FOR THE ANALYSIS OF ZRO2-POWDER

被引:40
作者
LOBINSKI, R
VANBORM, W
BROEKAERT, JAC
TSCHOPEL, P
TOLG, G
机构
[1] MAX PLANCK INST MET RES,REINSTSTOFFANALYT LAB,BUNSEN KIRCHHOFF STR 13,W-4600 DORTMUND 1,GERMANY
[2] INST SPEKTROCHEM & ANGEW SPEKTROSKOPIE,W-4600 DORTMUND 1,GERMANY
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1992年 / 342卷 / 07期
关键词
D O I
10.1007/BF00321915
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The optimization and use of ICP-AES with slurry nebulization for the direct analysis of ZrO2-powder is described. The powder samples are dispersed in water, acidified to pH 2 and the slurry is fed into a Babington nebulizer. The effects of grain size, pH of the suspending medium and standing time on the stability of the slurry are discussed. For the optimization of the ICP operating conditions, a simplex technique is applied and for this purpose three types of objective functions were examined. Identical behaviour of slurries and solutions with the same matrix concentrations in the ICP-AES is achieved for powders with particle sizes lower than 10-mu-m; in the latter case calibration can be performed by standard addition with aqueous solutions. The detection limits for Al, B, Ca, Cu, Fe, Mg, Mn, Na, Ti, V. Y are 0.03-mu-g/g to 10-mu-g/g and the standard deviation is generally lower than 10%. Six commercially available ZrO2 powders are analyzed by slurry nebulization ICP-AES and the results were found to agree well with those obtained by ICP-AES after chemical decomposition of the samples.
引用
收藏
页码:563 / 568
页数:6
相关论文
共 11 条
  • [1] ANALYSIS OF ADVANCED CERAMICS AND THEIR BASIC PRODUCTS
    BROEKAERT, JAC
    GRAULE, T
    JENETT, H
    TOLG, G
    TSCHOPEL, P
    [J]. FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 332 (08): : 825 - 838
  • [2] BROEKAERT JAC, 1989, FRESEN Z ANAL CHEM, V334, P631
  • [3] DIRECT ATOMIC SPECTROMETRIC ANALYSIS BY SLURRY ATOMIZATION .3. WHOLE COAL ANALYSIS BY INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY
    EBDON, L
    WILKINSON, JR
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1987, 2 (03) : 325 - 328
  • [4] DIRECT ATOMIC SPECTROMETRIC ANALYSIS BY SLURRY ATOMIZATION .5. ANALYSIS OF KAOLIN USING INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY
    EBDON, L
    COLLIER, AR
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (04) : 557 - 561
  • [5] ATOMIC EMISSION AND ATOMIC-ABSORPTION SPECTROMETRIC ANALYSIS OF HIGH-PURITY POWDERS FOR THE PRODUCTION OF CERAMICS
    GRAULE, T
    VONBOHLEN, A
    BROEKAERT, JAC
    GRALLATH, E
    KLOCKENKAMPER, R
    TSCHOPEL, P
    TOLG, G
    [J]. FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 335 (07): : 637 - 642
  • [6] INDUCTIVELY-COUPLED PLASMA ATOMIC EMISSION SPECTROSCOPIC DETERMINATION OF TRACE IMPURITIES IN ZRO2-POWDER
    LOBINSKI, R
    BROEKAERT, JAC
    TSCHOPEL, P
    TOLG, G
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (07): : 569 - 580
  • [7] Min H., 1989, SPECTROCHIM ACTA B, V44B, P957
  • [8] RAEYMAEKERS B, 1984, MIKROCHIM ACTA, V2, P437
  • [9] CHARACTERISTICS OF NEBULIZED SUSPENSIONS OF REFRACTORY OXIDE POWDERS USED FOR THE PRODUCTION OF CERAMICS AND THEIR EVAPORATION BEHAVIOR IN AN INDUCTIVELY COUPLED PLASMA
    RAEYMAEKERS, B
    GRAULE, T
    BROEKAERT, JAC
    ADAMS, F
    TSCHOPEL, P
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1988, 43 (08) : 923 - 940
  • [10] NOISE CHARACTERISTICS IN INDUCTIVELY COUPLED PLASMA OPTICAL-EMISSION SPECTROMETRY USING SLURRY NEBULIZATION AND DIRECT POWDER INTRODUCTION TECHNIQUES
    VANBORM, WA
    BROEKAERT, JAC
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (23) : 2527 - 2532