PREDICTION OF TOTAL KNEE MOTION USING A 3-DIMENSIONAL COMPUTER-GRAPHICS MODEL

被引:115
作者
GARG, A
WALKER, PS
机构
[1] UNIV LONDON UNIV COLL,INST ORTHOPAED,LONDON WC1E 6BT,ENGLAND
[2] BRIGHAM & WOMENS HOSP,ORTHOPAED BIOMECH LAB,BOSTON,MA 02115
关键词
Biological Materials--Ligaments;
D O I
10.1016/0021-9290(90)90368-D
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Twenty-three knees were sectioned, digitized, and standardized to determine the 'average' three-dimensional bony geometry and ligamentous attachments. Data on normal knee motion were obtained from a cadaveric study. An algorithm was written to simulate three-dimensional patella motion. Verification of the knee model was achieved by determining femoro-tibial and patello-femoral contact locations, as well as ligament length patterns, and comparing the results with published data. The criterion for maximum predicted knee motion with a prosthesis in place was the length of the posterior cruciate ligament. Three total knee replacement surfaces were mathematically generated: flat, laxity and conforming. A greater flexion angle was obtained with a flat tibial surface than for the laxity or conforming. Posterior tibial component displacement increased the range of motion, but only slightly. For all tibial surfaces, increased range of motion was achieved with a 10° posterior tilt of the tibial tray. Anterior femoral component displacement increased motion due to reduction in posterior cruciate tension during flexion. The results are applicable to the design and surgical technique of total knee replacement. © 1990.
引用
收藏
页码:45 / &
相关论文
共 33 条
  • [1] INVITRO MEASUREMENT OF STATIC PRESSURE DISTRIBUTION IN SYNOVIAL JOINTS .2. RETROPATELLAR SURFACE
    AHMED, AM
    BURKE, DL
    YU, A
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (03): : 226 - 234
  • [2] THE EFFECT OF CONFORMITY, THICKNESS, AND MATERIAL ON STRESSES IN ULTRAHIGH MOLECULAR-WEIGHT COMPONENTS FOR TOTAL JOINT REPLACEMENT
    BARTEL, DL
    BICKNELL, VL
    WRIGHT, TM
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) : 1041 - 1051
  • [3] BUTLER D, 1988, FEB P ORTH RES SOC A, P59
  • [4] COMPARISON OF MATERIAL PROPERTIES IN FASCICLE-BONE UNITS FROM HUMAN PATELLAR TENDON AND KNEE LIGAMENTS
    BUTLER, DL
    KAY, MD
    STOUFFER, DC
    [J]. JOURNAL OF BIOMECHANICS, 1986, 19 (06) : 425 - 432
  • [5] INTERACTION BETWEEN INTRINSIC KNEE MECHANICS AND THE KNEE EXTENSOR MECHANISM
    DRAGANICH, LF
    ANDRIACCHI, TP
    ANDERSSON, GBJ
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1987, 5 (04) : 539 - 547
  • [6] ERKMAN MJ, 1974, BIOMED ENG, V9, P14
  • [7] ESSINGER JR, 1987, JAN P ORTH RES SOC S, P290
  • [8] F icat P., 1970, PATHOLOGIE FEMORO PA
  • [9] PATELLO-FEMORAL JOINT MECHANICS AND PATHOLOGY .1. FUNCTIONAL-ANATOMY OF PATELLO-FEMORAL JOINT
    GOODFELLOW, J
    HUNGERFORD, DS
    ZINDEL, M
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1976, 58 (03): : 287 - 290
  • [10] PATELLOFEMORAL CONTACT PRESSURES - THE INFLUENCE OF Q-ANGLE AND TENDOFEMORAL CONTACT
    HUBERTI, HH
    HAYES, WC
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (05) : 715 - 724