Numerical research on the operation characteristics of marine variable air volume air conditioning system

被引:3
作者
Zhao, Zhongchao [1 ]
Zhang, Jiaojiao [1 ]
Cheng, Hua [1 ]
Shen, Rendong [1 ]
机构
[1] Jiangsu Univ Sci & Technol, Sch Energy & Power Engn, Zhenjiang, Peoples R China
关键词
Ship; VAV air conditioning system; operation characteristics;
D O I
10.1080/17512549.2017.1287128
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The aim of this study was to explore the operation characteristics of marine variable air volume (VAV) air conditioning system during navigation in each representative day and the whole voyage. In the multifunctional cabins of an ocean-going ship, numerical simulation was carried out to investigate diversified performance parameters of this system. At the same time, the mathematical models of main equipment and VAV system simulation model, which were coupled with an hourly dynamic load calculation model, were developed to analyse the energy consumption in a representative day and the whole voyage. The relative deviations of supply air volumes of all VAV terminals were within 11%, and the supply air temperature and room temperature fluctuated within +/- 0.2 K and +/- 0.3 K, respectively. Besides, the energy consumption of this system was lower than that of constant air volume air conditioning system, with the energy-saving rate of 26.82% by simulating calculation.
引用
收藏
页码:235 / 249
页数:15
相关论文
共 22 条
[1]   Simulation comparison of VAV and VRF air conditioning systems in an existing building for the cooling season [J].
Aynur, Tolga N. ;
Hwang, Yunho ;
Radermacher, Reinhard .
ENERGY AND BUILDINGS, 2009, 41 (11) :1143-1150
[2]   Simulation of a VAV air conditioning system in an existing building for the cooling mode [J].
Aynur, Tolga N. ;
Hwang, Yunho ;
Radermacher, Reinhard .
ENERGY AND BUILDINGS, 2009, 41 (09) :922-929
[3]  
Chen J., 2010, HV AC, V40, P61
[4]   Single-duct constant volume system optimization [J].
Cho, Young-Hum ;
Liu, Mingsheng .
ENERGY AND BUILDINGS, 2009, 41 (08) :856-862
[5]   Optimal supply air temperature with respect to energy use in a variable air volume system [J].
Engdahl, F ;
Johansson, D .
ENERGY AND BUILDINGS, 2004, 36 (03) :205-218
[6]   Control tuning of a simplified VAV system: Methodology and impact on energy consumption and IAQ [J].
Ginestet, S. ;
Marchio, D. .
ENERGY AND BUILDINGS, 2010, 42 (08) :1205-1214
[7]  
[晋欣桥 JIN Xin-qiao], 2009, [天津大学学报, Journal of Tianjin University], V42, P586
[8]   A study on the control method of single duct VAV terminal unit through the determination of proper minimum air flow [J].
Kang, Su-Hyun ;
Kim, Hyo-Jun ;
Cho, Young-Hum .
ENERGY AND BUILDINGS, 2014, 69 :464-472
[9]  
Lin X.-B., 2010, BUILDING ENERGY EFFI, V38, P44, DOI [10.3969/j.issn.1673-7237.2010.02.015, DOI 10.3969/J.ISSN.1673-7237.2010.02.015]
[10]  
Lin X.-B., 2010, BUILDING ENERGY ENV, V29, P20