FIXATION OF CANCELLOUS BONE AND PHYSEAL FRACTURES WITH BIODEGRADABLE RODS OF SELF-REINFORCED POLYLACTIC ACID

被引:8
作者
RAIHA, JE
AXELSON, P
SKUTNABB, K
ROKKANEN, P
TORMALA, P
机构
[1] MEVET SMALL ANIM CLIN,SF-00350 HELSINKI,FINLAND
[2] HELSINKI UNIV,CENT HOSP,DEPT ORTHOPAED & TRAUMATOL,SF-00260 HELSINKI,FINLAND
[3] UNIV TECHNOL TAMPERE,BIOMAT LAB,SF-33101 TAMPERE,FINLAND
关键词
D O I
10.1111/j.1748-5827.1993.tb02632.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
The frequent need for removal of metallic implants after fracture healing, has stimulated research into biodegradable osteosynthesis materials. The ideal biodegradable implant should support the fracture during healing and would slowly lose strength as the bone became able to resist the distracting forces. Decades of research into biodegradable materials has given much information on biocompatibility, degradation rates and processability of resorbable polyglycolides and polylactides. This has aided the development of an ultra high strength self-reinforcing composite construction allowing the manufacture of implants for several purposes. This study tested the use of self-reinforced poly-l-lactic acid rods for the fixation of cancellous fractures and osteotomies in 20 fixations in dogs and cats. The operating technique, callus formation, healing pattern, and functional and radiological end result, were evaluated. Two fixations failed but the functional end result was judged to be excellent in all but one of the healed cases. There was no need for surgery to remove the implants.
引用
收藏
页码:131 / 138
页数:8
相关论文
共 30 条
[1]  
AXELSON P, 1988, ACTA VET SCAND, V29, P477
[2]   THE USE OF A BIODEGRADABLE IMPLANT IN FRACTURE FIXATION - A REVIEW OF THE LITERATURE AND A REPORT OF 2 CLINICAL CASES [J].
AXELSON, P ;
RAIHA, J ;
MERO, M ;
VAINIONPAA, S ;
TORMALA, P ;
ROKKANEN, P .
JOURNAL OF SMALL ANIMAL PRACTICE, 1988, 29 (04) :249-255
[3]  
AXELSON P, 1988, ACTA VET SCAND, V29, P469
[4]   FOREIGN-BODY REACTIONS TO FRACTURE FIXATION IMPLANTS OF BIODEGRADABLE SYNTHETIC-POLYMERS [J].
BOSTMAN, O ;
HIRVENSALO, E ;
MAKINEN, J ;
ROKKANEN, P .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (04) :592-596
[5]  
Brinker WO., 1990, HDB SMALL ANIMAL ORT, P3
[6]  
Christel P, 1982, BIOMATERIALS 1980, P271
[7]  
CUTRIGHT DE, 1971, J ORAL SURG, V29, P393
[8]   DEGRADATION RATES OF POLYMERS AND COPOLYMERS OF POLYLACTIC AND POLYGLYCOLIC ACIDS [J].
CUTRIGHT, DE ;
PEREZ, B ;
BEASLEY, JD ;
LARSON, WJ ;
POSEY, WR .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1974, 37 (01) :142-152
[9]  
DEYOUNG DJ, 1985, TXB SMALL ANIMAL SUR, P1971
[10]   HEAT CAUSED BY DRILLING CORTICAL BONE - TEMPERATURE MEASURED INVIVO IN PATIENTS AND ANIMALS [J].
ERIKSSON, AR ;
ALBREKTSSON, T ;
ALBREKTSSON, B .
ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (06) :629-631