ERRORS IN THERMODILUTION CARDIAC-OUTPUT MEASUREMENTS CAUSED BY RAPID PULMONARY-ARTERY TEMPERATURE DECREASES AFTER CARDIOPULMONARY BYPASS

被引:72
作者
BAZARAL, MG [1 ]
PETRE, J [1 ]
NOVOA, R [1 ]
机构
[1] CLEVELAND CLIN,DEPT CARDIAC & THORAC SURG,CLEVELAND,OH 44106
关键词
MEASUREMENT TECHNIQUES; CARDIAC OUTPUT; THERMODILUTION; MONITORING; SURGERY; CARDIAC; CARDIOPULMONARY BYPASS; TEMPERATURE;
D O I
10.1097/00000542-199207000-00006
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
When systemic cooling and rewarming are performed during cardiopulmonary bypass (CPB), the pulmonary artery temperature typically decreases after CPB. This decrease may be rapid enough to cause substantial underestimation of cardiac output (CO) measured by thermodilution, due to changing baseline temperature during the thermodilution measurement. In 16 patients undergoing CPB for coronary artery grafts, digital recording of pulmonary artery temperature was done during room-temperature thermodilution CO (TDCO) injections. TDCO were computed with and without correction for baseline temperature decrease. Prior to CPB, the temperature change was 0.013-degrees-C/min, producing no significant effect on CO measurements; the coefficient of variation of CO measurements was 5.1%. One minute after CPB the temperature change was -0.144-degrees C/min, producing a CO measurement error of -0.57 +/- 0.52 l/min (SD), or about 11% of the average CO; the range of the error was 0.05 to -2.0 l/min. Ten minutes after CPB the temperature change was -0.063-degrees-C/min, and CO error was 0.31 +/- 0.36 (0.15 to -1.20) l/min. At 30 min the temperature change was 0.012-degrees-C/min (not significant), and CO error was 0.13 +/- 0.141/min. Duration of CPB was 104 +/- 30 min, with rewarming for 44 +/- 13 min; the average minimum bladder temperature was 25.1 +/- 2.3-degrees-C during cooling and 36.7 +/- 0.7-degrees-C at the end of CPB. Under these conditions TDCO measurements within the first 10 min after CPB often underestimate the true CO.
引用
收藏
页码:31 / 37
页数:7
相关论文
共 19 条
[1]   INTRAVASCULAR AND INTRACARDIAC BLOOD TEMPERATURES IN MAN [J].
AFONSO, S ;
ROWE, GG ;
CASTILLO, CA ;
CRUMPTON, CW .
JOURNAL OF APPLIED PHYSIOLOGY, 1962, 17 (04) :706-708
[2]   COMPUTERIZED MEASUREMENT OF CARDIAC-OUTPUT BY THERMODILUTION - METHODOLOGICAL ASPECTS [J].
ANDREEN, M .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1974, 18 (04) :297-305
[3]  
BAZARAL MG, 1988, ANESTHESIA HEART PAT, P277
[4]  
BJORAKER DG, 1983, ANESTH ANALG, V62, P1031
[5]   THERMAL BALANCE DURING CARDIOPULMONARY BYPASS WITH MODERATE HYPOTHERMIA IN MAN [J].
DAVIS, FM ;
PARIMELAZHAGAN, KN ;
HARRIS, EA .
BRITISH JOURNAL OF ANAESTHESIA, 1977, 49 (11) :1127-1132
[6]   MEASUREMENT OF CARDIAC OUTPUT IN ANAESTHETIZED ANIMALS BY A THERMO-DILUTION METHOD [J].
FEGLER, G .
QUARTERLY JOURNAL OF EXPERIMENTAL PHYSIOLOGY AND COGNATE MEDICAL SCIENCES, 1954, 39 (03) :153-164
[7]   THERMODILUTION CARDIAC-OUTPUT DETERMINATION WITH A SINGLE FLOW-DIRECTED CATHETER [J].
FORRESTER, JS ;
GANZ, W ;
SWAN, HJC ;
DIAMOND, G ;
CHONETTE, DW ;
MCHUGH, T .
AMERICAN HEART JOURNAL, 1972, 83 (03) :306-+
[8]   NEW TECHNIQUE FOR MEASUREMENT OF CARDIAC OUTPUT BY THERMODILUTION IN MAN [J].
GANZ, W ;
DONOSO, R ;
MARCUS, HS ;
FORRESTER, JS ;
SWAN, HJC .
AMERICAN JOURNAL OF CARDIOLOGY, 1971, 27 (04) :392-+
[9]   POSTOPERATIVE VENTILATORY AND CIRCULATORY EFFECTS OF EXTENDED REWARMING DURING CARDIOPULMONARY BYPASS [J].
JOACHIMSSON, PO ;
NYSTROM, SO ;
TYDEN, H .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1989, 36 (01) :9-19
[10]   DETERMINATION OF CARDIAC-OUTPUT BY THERMODILUTION DURING HYPOTHERMIA [J].
MERRICK, SH ;
HESSEL, EA ;
DILLARD, DH .
AMERICAN JOURNAL OF CARDIOLOGY, 1980, 46 (03) :419-422