A METHOD FOR MEASURING ELECTRON-ENERGY DISTRIBUTION IN A PLASMA-FOCUS

被引:17
作者
HIRANO, K
KANEKO, I
SHIMODA, K
YAMAMOTO, T
机构
[1] Department of Electronic Engineering, Gunma University, Kiryu, Gunma
来源
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS | 1990年 / 29卷 / 06期
关键词
Energetic electron beam; Magnetic energy analyzer; Reb;
D O I
10.1143/JJAP.29.1182
中图分类号
O59 [应用物理学];
学科分类号
摘要
A magnetic energy analyzer is designed for pulsed energetic electron beams, and successfully used to obtain energy distribution of the electron beam generated by a plasma focus device. In order to provide quick access of the electron energy distribution in a single shot, an electron detection system consisting of an MCP (microchannel plate) and a PCD (plasma-coupled device) linear image sensor is developed. Sensitivity calibration of the system is carried out using the nuclear emulsion sensitive to energetic electrons. Energy resolution and dynamic range of the detector are presented as functions of the electron energy. The major part of the energy-distributed electrons generated by the plasma focus device are in the relativistic region extending to higher than 1 MeV. The acceleration mechanism of those electrons up to such a huge energy is discussed. © 1990 The Japan Society of Applied Physics.
引用
收藏
页码:1182 / 1188
页数:7
相关论文
共 20 条
[1]   ABSOLUTE TIMING OF A RELATIVISTIC ELECTRON-BEAM IN A PLASMA-FOCUS [J].
CHOI, P ;
DEENEY, C ;
WONG, CS .
PHYSICS LETTERS A, 1988, 128 (1-2) :80-83
[2]   ION-BEAM FORMATION IN AN M = O UNSTABLE Z-PINCH [J].
HAINES, MG .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 207 (1-2) :179-185
[3]   CORRELATION BETWEEN TIME-RESOLVED SOFT-X-RAY IMAGES AND INTERFEROMETRIC RESULTS IN A PLASMA-FOCUS [J].
HIRANO, K ;
YAMAMOTO, T ;
SHIMODA, K ;
TAGAYA, Y .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1985, 24 (11) :1514-1517
[4]   A TIME-RESOLVED SOFT-X-RAY CAMERA SYSTEM WITH RAPID DATA-PROCESSING AND ITS APPLICATION TO A PINCHED-PLASMA EXPERIMENT [J].
HIRANO, K ;
NAKAJIMA, H ;
KANEKO, I ;
YAMAMOTO, T ;
SHIMODA, K .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1990, 29 (04) :779-784
[5]   CROSS CHECK OF ELECTRON-DENSITY DISTRIBUTION BY MOIRE-SCHLIEREN TECHNIQUE AND MACH-ZEHNDER INTERFEROMETRY [J].
HIRANO, K ;
MATSUMOTO, C ;
SHIMODA, K ;
YAMAMOTO, T .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1985, 24 (11) :1518-1521
[6]   PRODUCTION OF A HIGHLY IONIZED ION-BEAM BY A PLASMA-FOCUS [J].
HIRANO, K ;
YAMAMOTO, T ;
SHIMODA, K ;
NAKAJIMA, H .
JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1989, 58 (10) :3591-3599
[7]   TIME CORRELATION BETWEEN PLASMA BEHAVIOR AND SOFT-X-RAY EMISSION IN A PLASMA-FOCUS [J].
HIRANO, K ;
TAGAYA, Y ;
SHIMODA, K ;
OKABE, Y ;
YAMAMOTO, T .
JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1986, 55 (07) :2211-2216
[8]   MAGNETIC ENERGY ANALYZER WITH A MICROCHANNEL PLATE CALIBRATED USING CELLULOSE NITRATE FILM [J].
HIRANO, K ;
YAMAMOTO, T ;
OKABE, Y ;
SHIMODA, K .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1987, 58 (01) :20-25
[9]  
HIRANO K, 1988, PHYS FLUIDS, V321, P2710
[10]   FAST ION KINETICS AND FUSION REACTION-MECHANISM IN THE PLASMA-FOCUS [J].
JAGER, U ;
HEROLD, H .
NUCLEAR FUSION, 1987, 27 (03) :407-423