MIT MODULAR X-RAY SOURCE SYSTEMS FOR THE STUDY OF PLASMA DIAGNOSTICS

被引:1
|
作者
COLEMAN, JW
WENZEL, KW
PETRASSO, RD
LO, DH
LI, CK
LIERZER, JR
WEI, T
机构
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1992年 / 63卷 / 10期
关键词
D O I
10.1063/1.1143575
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Two new x-ray source systems are now on line at our facility. Each provides an e-beam to 25 kV. Targets are interchangeable between machines, and four x-ray detectors may be used simultaneously with a target. The gridded e-gun of the RACEHORSE system gives a 0.5-1.0-cm pulsable spot on target. The nongridded e-gun of the SCORPION system provides a 0.3-mm or smaller dc microspot on target. RACEHORSE is being used to study and characterize type-II diamond photoconductors for use in diagnosing plasmas, while SCORPION is being used to develop a slitless spectrograph using photographic film. Source design details and some RACEHORSE results are presented.
引用
收藏
页码:4834 / 4836
页数:3
相关论文
共 50 条
  • [31] ALUMINUM PLASMA X-RAY SOURCE FOR LITHOGRAPHY
    OKABE, M
    KITAMURA, Y
    FURUKAWA, Y
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1982, 129 (03) : C113 - C113
  • [32] X-ray diagnostics of plasma generated during collisions of plasma flows
    Gavrilov, V. V.
    Eskov, A. G.
    Zhitlukhin, A. M.
    Kochnev, D. M.
    Pikuz, S. A.
    Poznyak, I. M.
    Ryazantsev, S. N.
    Skobelev, I. Yu
    Toporkov, D. A.
    Umrikhin, N. M.
    XXXII INTERNATIONAL CONFERENCE ON INTERACTION OF INTENSE ENERGY FLUXES WITH MATTER (ELBRUS 2017), 2018, 946
  • [33] The Monochromatic Compton X-ray Source for Cancer Diagnostics and Therapy
    Zheng, D.
    Frederick, W. J.
    DeStefano, C.
    Vlieks, A. E.
    Landahl, E.
    Kwan, A.
    Heritage, J. P.
    Norman, A.
    Boone, J. M.
    Luhmann, N. C., Jr.
    CONFERENCE DIGEST OF THE 2006 JOINT 31ST INTERNATIONAL CONFERENCE ON INFRARED AND MILLIMETER WAVES AND 14TH INTERNATIONAL CONFERENCE ON TERAHERTZ ELECTRONICS, 2006, : 580 - 580
  • [34] Optimization of a laser-plasma x-ray source for contact x-ray microscopy
    Kondo, H., 1600, American Inst of Physics, Woodbury, NY, United States (75):
  • [35] A powerful soft X-ray source for X-ray lithography based on plasma focusing
    Bogolyubov, EP
    Bochkov, VD
    Veretennikov, VA
    Vekhoreva, LT
    Gribkov, VA
    Dubrovskii, AV
    Ivanov, YP
    Isakov, AI
    Krokhin, ON
    Lee, P
    Lee, S
    Nikulin, VY
    Serban, A
    Silin, PV
    Feng, X
    Zhang, GX
    PHYSICA SCRIPTA, 1998, 57 (04): : 488 - 494
  • [36] PULSED-PLASMA-BASED X-RAY SOURCE AND NEW X-RAY OPTICS
    RUDAKOV, LI
    BAIGARIN, KA
    KALININ, YG
    KOROLEV, VD
    KUMACHOV, MA
    PHYSICS OF FLUIDS B-PLASMA PHYSICS, 1991, 3 (08): : 2414 - 2419
  • [37] A SIMPLE CW X-RAY SOURCE FOR LASER PLASMA X-RAY DIAGNOSTIC ALIGNMENT
    HARES, JD
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1981, 14 (11): : 1306 - 1307
  • [38] Optimization of a Laser Plasma X-Ray Source for Ultrafast X-Ray Absorption Spectroscopy
    Iqbal, Mazhar
    Ijaz, Muhammad
    Noh, Do Young
    Janulewicz, Karol A.
    Stiel, Holger
    Nickles, Peter V.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2017, 70 (10) : 905 - 911
  • [39] OPTIMIZATION OF A LASER-PLASMA X-RAY SOURCE FOR CONTACT X-RAY MICROSCOPY
    KONDO, H
    TOMIE, T
    JOURNAL OF APPLIED PHYSICS, 1994, 75 (08) : 3798 - 3805
  • [40] Optimization of a laser plasma x-ray source for ultrafast x-ray absorption spectroscopy
    Mazhar Iqbal
    Muhammad Ijaz
    Do Young Noh
    Karol A. Janulewicz
    Holger Stiel
    Peter V. Nickles
    Journal of the Korean Physical Society, 2017, 70 : 905 - 911