Effect of Thermocycling, Teeth, and Polymerization Methods on Bond Strength Teeth-Denture Base

被引:24
作者
Andrade de Freitas, Sandra Lucia [1 ]
Brandt, William Cunha [2 ]
Miranda, Milton Edson [1 ]
Vitti, Rafael Pino [3 ]
机构
[1] Sao Leopoldo Mand, Sch Dent, Dept Prosthodont, Campinas, SP, Brazil
[2] Univ Santo Amaro, Sch Dent, Dept Implantol, Sao Paulo, SP, Brazil
[3] Univ Taubate, Sch Dent, Dept Prosthodont, Taubate, SP, Brazil
关键词
D O I
10.1155/2018/2374327
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. To evaluate the shear bond strength between different artificial teeth and denture base polymerized by two polymerization methods submitted to thermocycling. Materials and Methods. Two acrylic resins were selected according to the polymerization method (water-bath and microwave), and four different artificial teeth (Biotone, Dentsply; Trilux, Vipi Dent; Premium 8, Heraeus Kulzer; Soluut PX, Yamahachi) were also tested. The polymerization of the acrylic resin was performed by using conventional cycle (8 h at 74 degrees C) in water-bath and using two cycles (20 min at 270 W + 5 min at 360 W) by the microwave method. The shear bond strength was evaluated after 24 h of water storage at 37 degrees C (immediately) and after the thermocycling test (5,000 cycles, 5-55 degrees C). The shear bond strength (n = 10) was performed using a universal testing machine (Instron 4411) at a crosshead speed of 1.0 mm/min. Modes of failures were classified as cohesive and adhesive. The data (MPa) were statistically analyzed by three-way ANOVA, and the mean values were compared by the Tukey test (alpha = 0.05). Results. In general, the polymerization by microwave showed the highest shear bond strength values, and Trilux artificial teeth had the lowest bond strength values (p < 0.05). Thermocycling did not affect the shear bond strength (p < 0.05). + ere was a predominance of cohesive failures for all groups. Conclusions. The chemical composition of the artificial teeth affects the bond strength, and the microwave method is preferable to perform the acrylic resin polymerization.
引用
收藏
页数:5
相关论文
共 29 条
[1]   Optimization of Fracture Resistance and Stiffness of Heat-Polymerized High Impact Acrylic Resin with Localized E-Glass FiBER FORCE® Reinforcement at Different Stress Points [J].
Agha, Haitham ;
Flinton, Robert ;
Vaidyanathan, Tritala .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2016, 25 (08) :647-655
[2]  
Alla R, 2015, INT J APPL DENT SCI, V1, P82
[3]  
Arioli-Filho J. N., 2001, J APPL ORAL SCI, V19, P249
[4]   Flexural strength of acrylic resins polymerized by different cycles [J].
Barbosa, Debora Barros ;
de Souza, Raphael Freitas ;
Pero, Ana Carolina ;
Marra, Julie ;
Compagnoni, Marco Antonio .
JOURNAL OF APPLIED ORAL SCIENCE, 2007, 15 (05) :424-428
[5]   Bond strength of denture teeth to acrylic resin: effect of thermocycling and polymerisation methods [J].
Barbosa, Debora Barros ;
Ricardo Barao, Valentim Adelino ;
Monteiro, Douglas Roberto ;
Compagnoni, Marco Antonio ;
Marra, Julie .
GERODONTOLOGY, 2008, 25 (04) :237-244
[6]  
Chaves Carolina de Andrade Lima, 2009, Braz. Dent. J., V20, P127, DOI 10.1590/S0103-64402009000200007
[7]  
Fonseca R. B., 2015, SCI WORLD J, V2015
[8]  
GRANDO Matheus, 2015, RGO, Rev. Gaúch. Odontol., V63, P263, DOI 10.1590/1981-863720150003000022893
[9]   WEAR BEHAVIOR OF SEVEN ARTIFICIAL RESIN TEETH ASSESSED WITH THREE-DIMENSIONAL MEASUREMENTS [J].
Hao, Zhichao ;
Yin, Hongmin ;
Wang, Linxia ;
Meng, Yukun .
JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (06) :1507-1512
[10]  
Kasina Sitaram Prasad, 2014, J Int Oral Health, V6, P72