A 2-BAG SYSTEM FOR CONTINUOUS MEASUREMENT OF OXYGEN-UPTAKE

被引:0
|
作者
AUCHINCLOSS, JH
GILBERT, R
LIGHTY, GW
PEPPI, D
HARE, CL
机构
[1] Department of Medicine, Health Science Center, State University of New York, Syracuse, NY
关键词
D O I
10.1378/chest.102.1.112
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Collection of mixed expired gas in a bag has been a classic method for the estimation of VO2 during the steady state but has not been employed during unsteady state exercise in part because there is a need for suspending the acquisition of data during the period of gas analysis unless many bags are used. In this study a two-bag system is described in which one bag fills while the other is analyzed. Bag volume is under the control of the operator, and we employed volumes of 30 to 50 L. Thirty-one subjects were studied with this circuit in a progressive treadmill test. Although VO2 could be falsely elevated during periods of overbreathing, this source of error could be identified and its effect reduced if VO2 was plotted against both ventilation and power requirement. Plateau values of VO2 were identified only in six subjects and the ventilatory threshold in 16.
引用
收藏
页码:112 / 116
页数:5
相关论文
共 50 条
  • [1] AMBULATORY OXYGEN-UPTAKE MEASUREMENT SYSTEM
    TAMURA, T
    SATO, K
    TOGAWA, T
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (12) : 1274 - 1282
  • [2] MEASUREMENT OF OXYGEN-UPTAKE - A NEW SYSTEM FOR THE MEASUREMENT OF OXYGEN-UPTAKE DURING NITROUS-OXIDE IN OXYGEN ANESTHESIA
    COHEN, AT
    BEATTY, PCW
    KAY, B
    HEALY, TEJ
    BRITISH JOURNAL OF ANAESTHESIA, 1982, 54 (07) : P785 - P785
  • [3] APPARATUS FOR THE CONTINUOUS MEASUREMENT OF RESPIRATORY VOLUME AND OXYGEN-UPTAKE
    BRODIE, DA
    SALMONS, T
    JOURNAL OF PHYSIOLOGY-LONDON, 1980, 301 (APR): : P1 - P2
  • [4] CONTINUOUS OXYGEN-UPTAKE DETERMINATION
    ARTURSON, G
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1978, : 137 - 143
  • [5] CONTINUOUS MEASUREMENT OF OXYGEN-UPTAKE - EVALUATION OF THE ENGSTROM METABOLIC COMPUTER
    BEHRENDT, W
    KALFF, J
    GIANI, G
    MINALE, C
    BARSNICK, F
    INFUSIONSTHERAPIE UND KLINISCHE ERNAHRUNG, 1985, 12 (03): : 153 - +
  • [6] CONTINUOUS OXYGEN-UPTAKE DETERMINATION
    ARTURSON, G
    UPSALA JOURNAL OF MEDICAL SCIENCES, 1977, : 9 - 9
  • [7] SIMPLE, INEXPENSIVE APPARATUS FOR CONTINUOUS MEASUREMENT OF RESPIRATION BY OXYGEN-UPTAKE
    PHILLIPS, DE
    PASSAM, HC
    TROPICAL SCIENCE, 1976, 18 (02): : 125 - &
  • [8] RELIABILITY OF MEASUREMENT OF OXYGEN-UPTAKE BY A PORTABLE TELEMETRIC SYSTEM
    KAWAKAMI, Y
    NOZAKI, D
    MATSUO, A
    FUKUNAGA, T
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1992, 65 (05): : 409 - 414
  • [9] MEASUREMENT OF CORNEAL OXYGEN-UPTAKE
    SCHOESSLER, JP
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1981, 58 (08): : 614 - 617
  • [10] Validation of the portable VmaxST system for oxygen-uptake measurement
    Brehm, MA
    Harlaar, J
    Groepenhof, H
    GAIT & POSTURE, 2004, 20 (01) : 67 - 73