STARLING RESISTOR VERSUS COMPLIANCE - WHICH EXPLAINS THE ZERO-FLOW PRESSURE OF A DYNAMIC ARTERIAL PRESSURE-FLOW RELATION

被引:71
作者
MAGDER, S [1 ]
机构
[1] MCGILL UNIV,MEAKINS CHRISTIE LABS,MONTREAL H3A 2T5,QUEBEC,CANADA
关键词
compliance; critical pressure; pressure-flow relation; Starling resistor;
D O I
10.1161/01.RES.67.1.209
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Arterial pressure at zero flow (Pz = 0) that is higher than venous pressure (Pv) in dynamic pressure-flow relations has been explained by the presence of an arteriolar Starling resistor (SR) mechanism (i.e., vascular waterfall) or the discharge of vascular capacitance. To determine which was predominant, I studied in vivo hind limbs of 18 anesthetized dogs in which femoral arteries were cannulated with in-line electromagnetic flow probes to measure inflow (Q(in)), Pv was controlled, and collateral flow was eliminated with a tourniquet. Pz=0 was obtained by turning flow to zero. Three tests were applied: 1) Pv was raised in steps with either constant Q(in) or constant arterial pressure (Pa) to determine the pressure at which upstream vascular characteristics were affected by a change in Pv, 2) the time to reach Pz = 0 was varied to determine compliance effects, and 3) an equation was developed to determine if experimentally derived parameters could explain Pz = 0 without invoking an SR. With constant Q(in) and a Pz = 0 of 56.9 ± 11.7 mm Hg (time to Pz = 0,3 seconds), Pv could be raised by 9.6 ± 6.2 to 16.3 ± 6.0 mm Hg before Pa increased, and with constant Pa, Pv could be raised by 6.8 ± 7.3 to 14.0 ± 8.0 mm Hg before Q(in) decreased. With increasing times to reach Pz = 0, Pz = 0 initially dropped precipitously, but then decreased by only a small amount over the next 5-10 seconds even though arterial pressure was much above Pv. This could be explained by an SR mechanism with a critical pressure of 42.3 ± 11.4 mm Hg and an arterial complaince of 0.0104 ± 0.0023 ml·mm Hg-1 (n = 6). There was no value for the compliance that described the results when the arterial outflow pressure was Pv. Thus, this study supports the hypothesis that an SR mechanism is present in the vascular system. It is most likely precapillary, and in the resting limb, it has a value of 40-50 mm Hg. However, Pz = 0 in dynamic pressure-flow studies of less than 4 seconds is also greatly influenced by capacitance effects and the initial Pa.
引用
收藏
页码:209 / 220
页数:12
相关论文
共 41 条
[1]   PRELOAD-INDUCED ALTERATIONS IN CAPACITANCE-FREE DIASTOLIC PRESSURE-FLOW RELATIONSHIPS [J].
AVERSANO, T ;
KLOCKE, FJ ;
MATES, RE ;
CANTY, JM .
AMERICAN JOURNAL OF PHYSIOLOGY, 1984, 246 (03) :H410-H417
[2]   CENTRAL NEURAL INFLUENCE ON PRECAPILLARY MICROVESSELS AND SPHINCTER [J].
BAEZ, S ;
FELDMAN, SM ;
GOOTMAN, PM .
AMERICAN JOURNAL OF PHYSIOLOGY, 1977, 233 (01) :H141-H147
[3]  
BAEZ S, 1974, BLOOD VESSELS, V11, P260
[4]   DIASTOLIC CORONARY-ARTERY PRESSURE-FLOW RELATIONS IN DOG [J].
BELLAMY, RF .
CIRCULATION RESEARCH, 1978, 43 (01) :92-101
[5]   EFFECT OF CORONARY SINUS OCCLUSION ON CORONARY PRESSURE-FLOW RELATIONS [J].
BELLAMY, RF ;
LOWENSOHN, HS ;
EHRLICH, W ;
BAER, RW .
AMERICAN JOURNAL OF PHYSIOLOGY, 1980, 239 (01) :H57-H64
[6]   STEADY-STATE AND INSTANTANEOUS PRESSURE-FLOW RELATIONSHIPS - CHARACTERIZATION OF THE CANINE ABDOMINAL PERIPHERY [J].
BRAAKMAN, R ;
SIPKEMA, P ;
WESTERHOF, N .
CARDIOVASCULAR RESEARCH, 1983, 17 (10) :577-588
[7]   ON THE PHYSICAL EQUILIBRIUM OF SMALL BLOOD VESSELS [J].
BURTON, AC .
AMERICAN JOURNAL OF PHYSIOLOGY, 1951, 164 (02) :319-329
[8]   CHARACTERIZATION OF CAPACITANCE-FREE PRESSURE-FLOW RELATIONS DURING SINGLE DIASTOLES IN DOGS USING AN RC MODEL WITH PRESSURE-DEPENDENT PARAMETERS [J].
CANTY, JM ;
KLOCKE, FJ ;
MATES, RE .
CIRCULATION RESEARCH, 1987, 60 (02) :273-282
[9]   CORONARY VENOUS OUTFLOW PERSISTS AFTER CESSATION OF CORONARY ARTERIAL INFLOW [J].
CHILIAN, WM ;
MARCUS, ML .
AMERICAN JOURNAL OF PHYSIOLOGY, 1984, 247 (06) :H984-H990
[10]  
DEWEY RC, 1974, N NEUROSURG, V41, P597