SIMULTANEOUS DETERMINATION OF TRACE IMPURITIES IN HIGH-PURITY CHROMIUM METAL AND CHROMIUM DISILICIDE BY INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY AFTER COPRECIPITATION

被引:6
|
作者
KUJIRAI, O
YAMADA, K
HASEGAWA, R
机构
[1] National Research Institute for Metals, Meguro-ku, Tokyo 153, 2-3-12, Nakameguro
关键词
CHROMIUM METAL; CHROMIUM DISILICIDE; INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION SPECTROMETRY; COPRECIPITATION; SIMULTANEOUS DETERMINATION;
D O I
10.1039/ja9930800481
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Although chromium(III) was quantitatively coprecipitated with lanthanum hydroxide, chromate(VI) was not. The different behaviour of chromate(VI) was used for the analysis of chromium metal and chromium disilicide. Chromium (III) was oxidized to dichromate(VI) by fuming with perchloric acid and converted into chromate(VI). The pH was adjusted to 11.0 with sodium hydroxide solution. Ten trace elements (As, Co, Cu, Fe, Mn, Ni, Ti, V, Zn and Zr) in chromium metal and chromium disilicide were quantitatively coprecipitated with lanthanum hydroxide and separated from the chromium matrix. These trace elements were simultaneously determined by inductively coupled plasma atomic emission spectrometry using matrix-matched calibration solutions.