RESPIRATORY MONITORING DURING POSTOPERATIVE ANALGESIA

被引:8
作者
GORDH, T
RAWAL, N
STROM, S
HOK, B
机构
[1] From the Department of Anesthesiology and Intensive Care, University Hospital, Uppsala
[2] the Department of Anesthesiology and Intensive Care, Örebro Medical Centre Hospital, Örebro
[3] Basenhet Operation, the Central Hospital, Västerås
[4] Hök Instrument AB, Västerås
来源
JOURNAL OF CLINICAL MONITORING | 1995年 / 11卷 / 06期
关键词
EQUIPMENT; FLOW SENSOR; APNEA ALARM; MONITORING; RESPIRATORY RATE; ANESTHETICS; POSTOPERATIVE ANALGESIA;
D O I
10.1007/BF01616742
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Respiratory monitoring, using a novel flow sensor based on an acoustic principle, has been investigated in 30 patients during postoperative analgesia. Each patient was subjected to monitoring and human observation for 8 hr. The study was performed by independent observers at three clinics. Significant correlation was noted between respiratory rate (RR) determined by the sensor and the observers. Recordings of respiratory duration index (RDI), breathing time intervals (BTIs) indicated high sensitivity of the instrument to respiratory depression and perturbations in the breathing rhythm. More than 800 apnea alarms were noted, using an alarm setting of 30 sec; 61% of the categorized alarms were noted by the observers as true apneas. From the recordings it was shown that the number of alarms can be reduced by a factor of four if the alarm setting is changed to 45 sec. We conclude that the suggested technique, with slight modifications, provides adequate respiratory monitoring of patients during postoperative analgesia.
引用
收藏
页码:365 / 372
页数:8
相关论文
共 17 条
[1]  
Gustafsson L.L., Schildt B., Jacobsen K., Adverse effects of extradural and intrathecal opiates
[2]  
report of a nationwide survey in Sweden, Br J Anesth, 54, (1982)
[3]  
Vegfors M., Ugnell H., Hok B., Et al., Experimental evaluation of two new sensors for respiratory rate, Physiol Meas, 14, pp. 171-181, (1993)
[4]  
Wiklund L., Hok B., Stahl K., Jordeby-Jonsson A., Post-anesthesia monitoring revisited: Incidence of true and false alarms from different monitoring devices, J Clin Anesth, 6, pp. 182-188, (1994)
[5]  
Cyna A.M., Kulkarni V., Tunstall M.E., Et al., AURA: A new respiratory monitor and apnoea alarm for spontaneously breathing patients, Br J Anesth, 67, pp. 341-345, (1991)
[6]  
Hok B., Wiklund L., A new respiratory rate monitor: Development and initial clinical experience, International Journal of Clinical Monitoring and Computing, 10, pp. 101-107, (1993)
[7]  
Hok B., Microphone design for bioacoustic signals with suppression of noise and artifacts, Sensors and Actuators A: Physical, 25-27 A, pp. 527-533, (1991)
[8]  
Shibutani K., Komatsu T., Ogawa T., Et al., Monitoring of breathing intervals in narcotic sedation, Int J Clin Monit Comput, 8, pp. 159-162, (1991)
[9]  
Jense H.G., Dubin S.A., Silverstein P.I., O'Leary-Escolas U., Effect of obesity on safe duration of apnea in anesthetized humans, Anesth Analg, 72, pp. 89-93, (1991)
[10]  
Severinghouse J.W., Recent developments in pulse oximetry, Anesthesiology, 76, pp. 1018-1038, (1992)