STATUS OF THE DEVELOPMENT OF INSERTION DEVICES FOR ELETTRA

被引:22
作者
DIVIACCO, B
BRACCO, R
POLONI, C
WALKER, RP
ZANGRANDO, D
机构
[1] Sincrotrone Trieste, 34012 Trieste
关键词
D O I
10.1063/1.1142765
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The status of the development of insertion devices for the 1.5-2-GeV synchrotron radiation source ELETTRA is described. Recent results achieved with a prototype pure permanent magnet undulator and the construction and performance of a prototype hybrid multipole wiggler are presented. The parameters and design of the first undulator that will be constructed for ELETTRA, U12.5, are also presented, and some details are given about the magnetic measurement system.